• ABB Bailey NTDO02 Infi 90 Digital Output Termination Unit
  • ABB Bailey NTDO02 Infi 90 Digital Output Termination Unit
  • ABB Bailey NTDO02 Infi 90 Digital Output Termination Unit
  • ABB Bailey NTDO02 Infi 90 Digital Output Termination Unit
Product Overview The ABB Bailey NTDO02 Infi 90 Digital Output Termination Unit is a field-wiring interface used to connect digital output circuits from an ABB Bailey Infi 90 control system to external p……
ABB Bailey NTDO02 Infi 90 Digital Output Termination Unit
  • ABB Bailey
  • NTDO02
  • Digital Output Termination Unit
  • Sweden (SE)
  • 78.74 × 205.74 × 205.74 mm
  • 0.34 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

ABB Bailey NTDO02 Infi 90 Digital Output Termination Unit

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

ABB Bailey NTDO02 Infi 90 Digital Output Termination Unit

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

ABB Bailey NTDO02 Infi 90 Digital Output Termination Unit

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

ABB Bailey NTDO02 Infi 90 Digital Output Termination Unit

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The ABB Bailey NTDO02 Infi 90 Digital Output Termination Unit is a field-wiring interface used to connect digital output circuits from an ABB Bailey Infi 90 control system to external plant equipment. It provides a dedicated termination point between the active I/O electronics and discrete field devices.

Digital output circuits are commonly used for commands such as valve actuation, relay energization, motor start/stop signals, alarm outputs, and equipment interlocks. The NTDO02 organizes these field connections so that output signals from the control system can be routed to the appropriate external circuits.

The unit is a termination component rather than an independent controller or signal-processing module. Control logic remains within the associated Infi 90 controller and I/O electronics, while the NTDO02 handles the physical field connection layer.

For commissioning and maintenance, the termination unit provides a practical point for checking output wiring and signal paths. Incorrect terminal assignment, loose wiring, or a poor connection between the termination unit and I/O electronics can prevent an otherwise valid output command from reaching the field device.


Technical Specifications

Parameter Specification
Manufacturer ABB Bailey
Model NTDO02
Product Family Infi 90
Product Type Digital Output Termination Unit
Primary Function Digital output field-signal termination
System Role Digital output field-wiring interface
Application Infi 90 industrial process control systems
Dimensions 78.74 × 205.74 × 205.74 mm
Weight 0.34 kg

Product Features

  • Infi 90 Digital Output Termination Unit
  • Provides a dedicated interface for digital output field wiring
  • Connects compatible Infi 90 I/O electronics with external field circuits
  • Suitable for discrete control signals and equipment commands
  • Supports organized field wiring within industrial control installations
  • Useful for relay, actuator, alarm, and interlock output circuits
  • Passive termination component without independent control logic
  • Suitable for commissioning, maintenance, and replacement applications

Working Principle

The NTDO02 provides the physical connection between the digital output channels of the Infi 90 I/O system and the external field circuits. A control command generated by the controller is processed by the associated I/O electronics and then transferred through the termination arrangement to the connected field device.

Infi 90 Controller → Digital Output I/O → NTDO02 → Field Wiring → Actuator / Relay / Indication Device

When an output channel changes state, the corresponding electrical condition is presented through the NTDO02 termination point. The connected field equipment then responds according to its own electrical and control characteristics.

The NTDO02 does not determine when an output should operate. It maintains the physical signal path between the active I/O circuitry and field wiring. A problem at the termination point can therefore appear as a failed output even though the controller and I/O logic are functioning correctly.


Role in an ABB Bailey Infi 90 Digital Output Architecture

The NTDO02 occupies the field termination layer of an Infi 90 digital output system. It sits between the active digital output electronics and the plant wiring used by external discrete devices.

Infi 90 Controller → Digital Output Module → NTDO02 → Field Wiring → External Equipment

System Element Function
Infi 90 Controller Executes control logic and operating sequences
Digital Output Module Generates configured discrete output states
NTDO02 Terminates and interfaces digital output wiring
Field Wiring Carries output commands to external equipment
Relay / Interface Transfers or isolates the output circuit
Actuator Performs the commanded physical action
Alarm / Indication Provides discrete equipment or process indication

This arrangement separates controller logic and active I/O processing from the physical field-wiring interface, making individual output circuits easier to identify during commissioning and troubleshooting.


Industrial Applications

Application Typical Use
Process Automation Termination of discrete control outputs
Valve Control Routing commands to compatible valve circuits
Motor Control Interface for start/stop and auxiliary circuits
Power Generation Discrete commands for plant equipment
Boiler and Turbine Systems Equipment control and interlock outputs
Chemical Processing Actuator and auxiliary equipment control
Oil and Gas Facilities Field output signal termination
Water Treatment Control of pumps, valves, and auxiliary devices
Industrial Utilities Discrete output wiring organization

Installation and Maintenance

  1. Verify that the NTDO02 matches the intended Infi 90 digital output termination arrangement.
  2. Review the approved control-system drawings before disconnecting existing field wiring.
  3. Isolate the relevant output circuits according to applicable maintenance and safety procedures.
  4. Inspect the NTDO02 for physical damage, contamination, or loose components.
  5. Confirm terminal identification and output-channel assignments against the system documentation.
  6. Check field conductors for damaged insulation, loose terminals, or incorrect wiring.
  7. Verify the connection between the NTDO02 and the associated Infi 90 digital output electronics.
  8. Confirm that the connected field load is appropriate for the complete output circuit.
  9. Energize the system under controlled commissioning conditions.
  10. Test each affected output channel using an approved commissioning procedure.
  11. Compare the controller command, I/O output state, termination point, and actual field-device response when troubleshooting.
  12. After replacement, verify all affected output circuits and complete the required functional test before returning the process to normal operation.

Compatible System Components

Component Function
ABB Bailey Infi 90 Controller Executes process-control and sequencing logic
Infi 90 Digital Output Module Generates discrete output signals
NTDO02 Terminates digital output field wiring
Field Terminal Wiring Carries output signals to connected equipment
Interposing Relay Provides switching or electrical interface
Solenoid Valve Performs a discrete process-control action
Motor Starter Provides motor start/stop control
Alarm / Indication Device Provides equipment or process status indication
Field Actuator Performs the commanded physical operation

Recommended Related Models

Model / Product Family Product Type Typical Application
ABB Bailey NTDO02 Digital Output Termination Unit Infi 90 digital output termination
ABB Bailey NTDO01 Digital Output Termination Unit Infi 90 output field interfacing
ABB Bailey NTDI21 Digital I/O Termination Unit Infi 90 digital I/O field interface
ABB Bailey NTDI02 Digital I/O Termination Unit Infi 90 digital signal termination
ABB Bailey NTDI01 Digital Input Termination Unit Infi 90 digital input interfacing
ABB Bailey NTCU01 Serial Interface Termination Unit Infi 90 serial communication interface
ABB Bailey NTCS04 Control Station Termination Unit Infi 90 control station interfacing
ABB Bailey Infi 90 Series Distributed Control System Industrial process automation

Key Advantages

  • Provides a dedicated termination interface for Infi 90 digital output circuits.
  • Organizes field wiring for discrete control commands.
  • Separates field connections from active controller and I/O electronics.
  • Supports practical channel-level commissioning and troubleshooting.
  • Suitable for valves, relays, alarms, motor-control circuits, and other discrete loads.
  • Useful for maintenance and replacement of compatible Infi 90 output termination arrangements.

Technical FAQs

What is the difference between the NTDO02 and an Infi 90 digital output module?

The NTDO02 is a field termination unit, while the digital output module performs the active I/O function. The controller and I/O module determine the output state, and the NTDO02 provides the physical interface to the field wiring.

What types of equipment can receive signals through the NTDO02?

It can form part of digital output circuits connected to compatible equipment such as relays, solenoids, valve interfaces, alarms, interlocks, and motor-control circuits. The complete field circuit must be checked for compatibility.

How can an NTDO02 wiring problem appear during commissioning?

A controller may show the expected output state while the external device fails to respond. In that situation, the termination point, field wiring, intermediate relay or interface, and field device should be checked in sequence.

What should be verified after replacing an NTDO02?

Confirm the terminal assignments, channel mapping, connection to the Infi 90 output electronics, and field wiring. Each affected output should then be tested from the controller command through to the actual field-device response.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501