• Schneider BMXNOE0100H Modicon M340 Ethernet TCP/IP Network Module
  • Schneider BMXNOE0100H Modicon M340 Ethernet TCP/IP Network Module
  • Schneider BMXNOE0100H Modicon M340 Ethernet TCP/IP Network Module
  • Schneider BMXNOE0100H Modicon M340 Ethernet TCP/IP Network Module
Product Overview The Schneider BMXNOE0100H Modicon M340 Ethernet TCP/IP Network Module is a communication module for integrating a Modicon M340 automation system with Ethernet TCP/IP networks. It provid……
Schneider BMXNOE0100H Modicon M340 Ethernet TCP/IP Network Module
  • Schneider
  • BMXNOE0100H
  • Ethernet TCP/IP Network Module
  • France
  • 55 × 110 × 120 mm
  • 0.2 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 10

Our advantage

Schneider BMXNOE0100H Modicon M340 Ethernet TCP/IP Network Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider BMXNOE0100H Modicon M340 Ethernet TCP/IP Network Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider BMXNOE0100H Modicon M340 Ethernet TCP/IP Network Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider BMXNOE0100H Modicon M340 Ethernet TCP/IP Network Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider BMXNOE0100H Modicon M340 Ethernet TCP/IP Network Module is a communication module for integrating a Modicon M340 automation system with Ethernet TCP/IP networks. It provides the network interface needed for exchanging application and diagnostic information between the M340 platform and connected Ethernet devices.

The module is used at the network communication layer of an M340 installation. The PLC processor continues to execute the control application, while the BMXNOE0100H handles communication with external Ethernet equipment such as supervisory computers, operator interfaces, networked controllers, and other automation devices.

In a production or process-control installation, the module can provide an Ethernet communication path between the M340 controller and higher-level or distributed systems. This allows PLC information to be exchanged without placing network communication responsibilities directly on the controller’s local I/O interfaces.

For commissioning and maintenance, the Ethernet network module provides a useful point for checking communication status independently from the PLC’s field I/O. Network connectivity, module status, addressing, cabling, and remote-device availability can be examined when communication problems occur.


Technical Specifications

Parameter Specification
Manufacturer Schneider Electric
Model BMXNOE0100H
Product Family Modicon M340
Product Type Ethernet TCP/IP Network Module
Primary Function Ethernet TCP/IP network communication
System Role PLC network communication interface
Typical Application Industrial automation and Ethernet networking
Dimensions 55 × 110 × 120 mm
Weight 0.2 kg

Product Features

  • Ethernet TCP/IP network interface for Modicon M340 systems
  • Provides communication between the M340 platform and Ethernet devices
  • Supports network connectivity at the PLC communication layer
  • Suitable for distributed industrial automation architectures
  • Can exchange control-system information with networked equipment
  • Useful for supervisory and operator-system integration
  • Provides a dedicated Ethernet communication point within the M340 architecture
  • Suitable for commissioning and troubleshooting Ethernet-connected systems

Working Principle

The BMXNOE0100H provides the communication path between the Modicon M340 system and connected Ethernet TCP/IP devices. Information generated by the PLC application can be transferred through the network module to external equipment, while incoming network information can be delivered to the M340 environment for use by the control application.

The module handles the network communication interface rather than replacing the processor’s control functions. The M340 CPU remains responsible for executing the application program, while the BMXNOE0100H manages the Ethernet connection used for communication with external systems.

Modicon M340 CPU → BMXNOE0100H → Ethernet TCP/IP Network → HMI / SCADA / Remote Device

Communication performance depends on the complete network path. A fault may originate from the module, Ethernet cabling, network equipment, addressing, configuration, or the remote device. Checking these elements separately helps identify the actual source of a communication problem.


Role in a Modicon M340 Ethernet TCP/IP Control Architecture

The BMXNOE0100H occupies the network communication layer of a Modicon M340 control system. It connects the PLC environment with external Ethernet TCP/IP equipment while the M340 processor continues to execute machine or process-control logic.

M340 CPU → BMXNOE0100H Ethernet Network Module → Ethernet Switch / Network → HMI / SCADA / Remote Automation Equipment

System Element Function
Modicon M340 CPU Executes the PLC application and control logic
BMXNOE0100H Provides Ethernet TCP/IP network communication
Ethernet Switch Connects multiple networked automation devices
HMI Provides operator visualization and machine interaction
SCADA System Provides supervisory monitoring and data collection
Remote Automation Equipment Exchanges process and control information over Ethernet
Engineering Station Supports configuration, diagnostics, and maintenance

Industrial Applications

Application Typical Use
Machine Automation Ethernet communication between M340 controllers and equipment
Process Automation Exchange of process data with networked systems
Production Lines Communication between PLCs, HMIs, and auxiliary equipment
Packaging Machinery Network connection for machine supervision
Material Handling Communication with distributed automation equipment
HMI / SCADA Integration Transfer of PLC information to supervisory systems
Manufacturing Networks Integration of M340 systems into Ethernet infrastructure
Distributed Control Panels Ethernet communication between separated control stations

Installation and Maintenance

  1. Confirm that the BMXNOE0100H matches the intended Modicon M340 Ethernet communication architecture.
  2. Install the module in the appropriate M340 rack position according to the system configuration.
  3. Verify that the module is correctly seated and mechanically secured.
  4. Inspect the Ethernet cable and connectors before establishing the network connection.
  5. Confirm that the network equipment connected to the module is powered and operational.
  6. Check the Ethernet network configuration and addressing used by the application.
  7. Verify communication indicators and module status during commissioning.
  8. Test communication between the M340 system and each required network device.
  9. Check Ethernet switches and intermediate network connections if communication is unavailable.
  10. Investigate intermittent communication by checking connectors, cabling, network configuration, and remote-device status.
  11. Record the existing network configuration before replacing the module where applicable.
  12. After replacement, verify both network connectivity and application-level data exchange before returning the control system to normal operation.

Compatible System Components

Component Function
Modicon M340 CPU Executes PLC application and machine-control logic
BMXNOE0100H Provides Ethernet TCP/IP network communication
Modicon M340 Rack Provides the module installation platform
Ethernet Switch Connects multiple network devices
HMI Terminal Provides operator visualization and control
SCADA System Provides supervisory monitoring and process data collection
Engineering PC Supports configuration and diagnostics
Ethernet Network Cable Provides the physical communication path

Recommended Related Models

Model / Product Family Product Type Typical Application
Schneider Modicon M340 PLC Platform Machine and process automation
Schneider BMXP34 Series M340 Processor PLC control and application execution
Schneider BMXNOE Series Ethernet Communication Module M340 Ethernet networking
Schneider BMXNOC Series Ethernet Communication Module M340 network communication
Schneider Modicon X80 I/O and Communication Platform Distributed automation infrastructure
Schneider Ethernet Switches Industrial Network Equipment Ethernet network connectivity

Key Advantages

  • Provides Ethernet TCP/IP connectivity for Modicon M340 systems
  • Connects M340 controllers with networked automation equipment
  • Separates network communication from PLC application execution
  • Supports integration with HMI, SCADA, and distributed control equipment
  • Provides a dedicated point for Ethernet communication diagnostics
  • Suitable for machine and process automation networks

Technical FAQs

What is the difference between the BMXNOE0100H and an M340 CPU?

The BMXNOE0100H is a network communication module, while the M340 CPU executes the PLC application and control logic. The two components work together to connect the controller to Ethernet-based systems.

What should be checked if the BMXNOE0100H cannot communicate with a remote device?

Check the module status, Ethernet connection, network equipment, addressing, communication configuration, and remote-device availability. If the physical network is operational, the application-level communication settings should also be reviewed.

Can the BMXNOE0100H be connected directly to an HMI?

It can participate in an Ethernet communication path between the M340 system and an HMI, provided that the network architecture and communication configuration support the intended connection.

Why is the BMXNOE0100H useful in a distributed automation system?

It gives the M340 control system a dedicated Ethernet TCP/IP communication interface, allowing controller information to be exchanged with HMIs, supervisory systems, and other networked automation equipment without using the module as a replacement for the PLC processor.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501