Product Overview The Emerson SE4006P2 KJ3241X1-BK1 + KJ4006X1-BD1 DeltaV S-series Serial Interface Card is a serial communication interface assembly used with DeltaV S-series control systems. The assemb……
Emerson SE4006P2 KJ3241X1-BK1 + KJ4006X1-BD1 DeltaV S-series Serial Interface Card
  • Emerson
  • SE4006P2 KJ3241X1-BK1 + KJ4006X1-BD1
  • Serial Interface Card
  • USA
  • 131 × 41.8 × 130.8 mm
  • 0.29 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 10

Our advantage

Emerson SE4006P2 KJ3241X1-BK1 + KJ4006X1-BD1 DeltaV S-series Serial Interface Card

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Emerson SE4006P2 KJ3241X1-BK1 + KJ4006X1-BD1 DeltaV S-series Serial Interface Card

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Emerson SE4006P2 KJ3241X1-BK1 + KJ4006X1-BD1 DeltaV S-series Serial Interface Card

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Emerson SE4006P2 KJ3241X1-BK1 + KJ4006X1-BD1 DeltaV S-series Serial Interface Card

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Emerson SE4006P2 KJ3241X1-BK1 + KJ4006X1-BD1 DeltaV S-series Serial Interface Card is a serial communication interface assembly used with DeltaV S-series control systems. The assembly combines the SE4006P2 interface card with its associated hardware components to establish serial communication between the DeltaV system and compatible external equipment.

In a plant environment, this type of interface is useful when intelligent instruments, packaged equipment, controllers, or other subsystem devices exchange operational data through serial communication. Instead of bringing every device into the control system through individual analog and discrete signals, serial communication can carry equipment information through an established communication interface.

The KJ3241X1-BK1 and KJ4006X1-BD1 designations identify associated DeltaV hardware within the complete assembly. For replacement work, technicians should therefore verify the complete combination rather than checking only the SE4006P2 card number.

The assembly is particularly relevant to existing DeltaV installations where maintaining the original communication architecture is important. Troubleshooting should cover the card, associated hardware, serial connection, external device, and DeltaV configuration as one communication path.


Technical Specifications

Parameter Specification
Model SE4006P2
Associated Part Numbers KJ3241X1-BK1 + KJ4006X1-BD1
Product Family Emerson DeltaV S-series
Product Type Serial Interface Card
Primary Function Serial communication interface
System Role Control system communication interface
Application Industrial automation and process control
Dimensions 131 × 41.8 × 130.8 mm
Weight 0.29 kg

Product Features

  • Serial communication interface for DeltaV S-series systems
  • Complete assembly identified by SE4006P2, KJ3241X1-BK1, and KJ4006X1-BD1
  • Supports integration of compatible serial equipment
  • Suitable for intelligent instruments and packaged control systems
  • Provides a dedicated communication path between external equipment and DeltaV
  • Useful for equipment data exchange and supervisory functions
  • Fits existing DeltaV S-series control architectures
  • Suitable for maintenance and replacement of installed DeltaV communication hardware

Working Principle

The SE4006P2 KJ3241X1-BK1 + KJ4006X1-BD1 assembly establishes the physical interface between the DeltaV S-series architecture and compatible serial equipment. Data from the external device travels through the serial connection into the interface assembly and is then made available to the DeltaV control system.

External Serial Equipment → Serial Connection → SE4006P2 Assembly → DeltaV S-series I/O → DeltaV Controller

Communication can also operate in the opposite direction when the application requires commands, requests, or configuration-related data to be transferred from DeltaV toward the connected equipment.

For troubleshooting, the communication path should be treated as a complete circuit. A communication failure can result from the external device, wiring, interface assembly, configuration, or communication parameters, even when the SE4006P2 itself has no visible physical fault.


Role in a DeltaV S-series Control Architecture

The assembly serves as the serial communication layer between external intelligent equipment and the DeltaV control system. It differs from analog and digital I/O cards because its primary task is exchanging structured device data rather than handling individual continuous or discrete field signals.

External Intelligent Device → Serial Interface Assembly → DeltaV S-series I/O → DeltaV Controller → HMI / SCADA

System Element Function
External Intelligent Device Generates or receives serial equipment data
KJ4006X1-BD1 Associated hardware within the serial interface assembly
KJ3241X1-BK1 Associated DeltaV hardware for the complete interface arrangement
SE4006P2 Provides the serial communication interface
DeltaV Controller Processes received data and executes control strategies
HMI / Operator Station Displays equipment information and communication status

Industrial Applications

Application Typical Use
Process Automation Integration of serial intelligent equipment
Packaged Equipment Connecting vendor control systems to DeltaV
Oil and Gas Equipment data exchange and supervisory monitoring
Power Generation Communication with auxiliary control equipment
Chemical Processing Integration of intelligent process devices
Industrial Utilities Serial communication with utility equipment

Installation and Maintenance

  1. Verify the complete SE4006P2, KJ3241X1-BK1, and KJ4006X1-BD1 combination before installation.
  2. Confirm compatibility with the existing DeltaV S-series architecture.
  3. Check the serial interface requirements of the connected external device.
  4. Verify communication wiring and terminal assignments before commissioning.
  5. Confirm that the external device is powered and operating normally.
  6. Check communication parameters and addressing at both ends of the serial connection.
  7. Inspect connectors and terminals for looseness, contamination, or physical damage.
  8. Check the interface assembly when communication is unavailable or unstable.
  9. Determine whether the fault affects one external device or several devices using the same communication architecture.
  10. Compare DeltaV communication status with the operating status of the connected equipment.
  11. Record the existing hardware combination and wiring before removing the assembly for replacement.
  12. After replacement, verify stable communication and confirm that valid device data is available to the DeltaV system.

Related Components

Component Function
DeltaV Controller Processes communication data and executes control strategies
SE4006P2 Provides the serial communication interface
KJ3241X1-BK1 Associated hardware in the interface assembly
KJ4006X1-BD1 Associated hardware in the interface assembly
Serial Communication Cable Transfers data between the interface and external equipment
External Serial Device Exchanges operational data with DeltaV
DeltaV S-series I/O Carrier Provides the physical I/O platform
DeltaV Engineering Station Used for configuration and maintenance

Recommended Related Models

Model / Product Family Product Type Typical Application
Emerson SE4006P2 DeltaV S-series Serial Interface Card Serial device integration
Emerson SE4006P2 KJ3241X1-BK1 + KJ4006X1-BD1 Serial Interface Assembly DeltaV serial communication
Emerson DeltaV S-series Serial Interface Cards Serial Communication Intelligent equipment integration
Emerson DeltaV S-series Analog Input Cards Analog Input Process measurement acquisition
Emerson DeltaV S-series Analog Output Cards Analog Output Continuous process control
Emerson DeltaV S-series Digital Input Cards Digital Input Discrete signal acquisition
Emerson DeltaV S-series Digital Output Cards Digital Output Discrete equipment control
Emerson DeltaV S-series I/O Carriers I/O Carrier S-series I/O installation

Key Advantages

  • Complete serial interface assembly for compatible DeltaV S-series systems
  • Combines the SE4006P2 interface with associated DeltaV hardware
  • Suitable for intelligent equipment and packaged-system integration
  • Supports serial data exchange within the control architecture
  • Useful for maintaining established DeltaV communication installations
  • Practical for replacement and field-service applications

Technical FAQs

Why should the three part numbers be checked together when replacing this assembly?

The complete identification includes SE4006P2, KJ3241X1-BK1, and KJ4006X1-BD1. Checking only the main card number may not be sufficient when the installed system depends on the associated hardware arrangement.

What is the difference between this assembly and a DeltaV analog I/O card?

An analog I/O card handles continuous electrical signals, while the SE4006P2 assembly is used for serial data communication with compatible external equipment. The communication architecture and configuration requirements are therefore different.

What can cause communication loss after replacing the assembly?

Incorrect hardware selection, wiring problems, connector issues, communication parameters, device addressing, or DeltaV configuration can all prevent successful communication. The complete communication path should be checked rather than assuming the replacement card is defective.

What should be documented before removing the existing SE4006P2 assembly?

Record the complete part-number combination, wiring arrangement, connected equipment, communication configuration, and relevant channel or system settings. This information makes it easier to reproduce the original communication arrangement after replacement.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501