The GE IC697ACC702 Bus Terminal Plug is a compact industrial connection component designed for use within compatible GE programmable controller and automation system bus architectures. Its primary purpose is to provide a secure termination or connection point for a controller communication bus, helping maintain proper electrical continuity and network integrity.
In industrial control systems, bus termination components are essential for maintaining reliable communication, particularly on networks where signal reflections, impedance mismatch, loose connections, or incorrect termination can result in intermittent communication errors.
The IC697ACC702 has supplied dimensions of 50 × 20 × 15 mm and a listed weight of 0.04 kg, making it a compact component suitable for installation in space-constrained control cabinets.
| Parameter | Specification |
|---|---|
| Manufacturer | GE |
| Model | IC697ACC702 |
| Product Type | Bus Terminal Plug |
| Product Category | Industrial Bus Connection Component |
| Primary Function | Bus Termination / Connection |
| Dimensions | 50 × 20 × 15 mm |
| Weight | 0.04 kg |
| Installation | Compatible GE Bus Interface |
| Application | PLC / Industrial Automation |
| Maintenance | Connection and Termination Inspection |
| Technical Item | Specification |
|---|---|
| Brand | GE |
| Model Number | IC697ACC702 |
| Product Type | Bus Terminal Plug |
| Function | Bus Connection / Termination |
| Application | Industrial Controller Network |
| Dimensions | 50 × 20 × 15 mm |
| Weight | 0.04 kg |
| Installation Method | Plug-In Connection |
| Environment | Industrial Control Cabinet |
| Maintenance | Periodic Inspection |
A bus terminal plug is a connection component used to establish or terminate an industrial communication bus according to the architecture of the control system.
A typical control-system arrangement can be represented as:
PLC / Controller
↓
Bus Interface
↓
Bus Cable
↓
Bus Terminal Plug
↓
Remote Controller / Bus Device
The terminal component helps maintain the intended electrical characteristics of the bus.
Incorrect termination can lead to:
For this reason, the physical condition and correct placement of the terminal plug should be checked during commissioning and maintenance.
Provides a physical interface for connecting the compatible bus wiring or network segment.
Where required by the applicable bus architecture, provides the termination needed to maintain proper signal behavior.
A correctly installed terminal plug helps prevent communication problems caused by incorrect bus configuration or termination.
The compact plug-in design allows technicians to inspect, remove, and replace the component efficiently.
The GE IC697ACC702 may be incorporated into compatible GE industrial control systems used in:
Before installation, confirm:
Do not install a bus terminal plug based solely on its physical appearance.
Before handling the bus connection:
Before installing the plug, inspect the mating interface for:
A contaminated interface can cause intermittent communication.
Check the terminal plug for:
Do not install a damaged plug.
The terminal plug must be installed at the correct point in the bus architecture.
Incorrect placement can cause communication problems.
Before installation, verify whether the plug is required at:
Align the IC697ACC702 with the compatible bus interface.
Insert it carefully until fully seated.
Verify:
Do not force the connector.
The supplied dimensions are:
50 × 20 × 15 mm
The supplied weight is:
0.04 kg
After installation confirm:
After completing the installation:
Confirm:
| Item | Verification |
|---|---|
| Correct IC697ACC702 Verified | Confirmed |
| Bus Architecture Checked | Confirmed |
| Power Isolation Completed | Confirmed |
| Connector Inspected | Confirmed |
| Correct Installation Location Verified | Confirmed |
| Terminal Plug Installed | Confirmed |
| Mechanical Connection Secure | Confirmed |
| Bus Communication Tested | Confirmed |
| Diagnostics Normal | Confirmed |
Possible causes include:
Start by inspecting the physical bus connection and termination points.
Possible causes:
Inspect the plug and the complete bus wiring.
Possible causes include:
Check the physical network first, then review controller diagnostics.
If several devices disappear from the network simultaneously, investigate:
A common physical bus problem is more likely than multiple independent device failures.
Possible causes include:
Inspect cable routing and termination before replacing communication modules.
Possible causes include:
Review the system topology and verify that termination is implemented exactly as required.
Possible causes:
Never force the component into the interface.
Check:
Inspect:
Perform:
| Inspection Item | Status |
|---|---|
| Terminal Plug Housing Inspected | ✓ |
| Contacts Checked | ✓ |
| Bus Interface Inspected | ✓ |
| Plug Fully Seated | ✓ |
| Cable Connection Verified | ✓ |
| Termination Location Verified | ✓ |
| Network Communication Tested | ✓ |
| Diagnostics Checked | ✓ |
When replacing an IC697ACC702, technicians should verify the complete bus configuration.
| Check Item | Purpose |
|---|---|
| Model Number | Confirms component identity |
| Bus Type | Ensures correct application |
| Installation Location | Prevents incorrect termination |
| Connector Type | Ensures physical compatibility |
| Bus Cable | Confirms network integrity |
| Network Topology | Prevents termination errors |
| Controller Configuration | Ensures system compatibility |
| Environmental Conditions | Supports long-term reliability |
The bus terminal plug normally operates as part of a larger industrial automation network.
| Component | Function |
|---|---|
| GE PLC / Controller | Executes Control Program |
| Bus Interface | Provides Network Connection |
| Bus Cable | Carries Communication Signals |
| Terminal Plug | Provides Bus Connection / Termination |
| Remote I/O | Distributed Field Interface |
| I/O Modules | Process Field Signals |
| Power Supply | Provides Electrical Power |
| Engineering Workstation | Configuration and Diagnostics |
Exact compatibility depends on the installed GE controller and bus architecture.
The supplied dimensions of 50 × 20 × 15 mm allow convenient installation in compact control cabinets.
With a listed weight of 0.04 kg, the component is easy to handle during maintenance.
A properly installed terminal plug helps maintain stable bus communication.
The plug-in design allows technicians to inspect or replace the component without extensive mechanical work.
Correct bus termination helps reduce communication problems associated with improper signal termination.
The GE IC697ACC702 is a Bus Terminal Plug used as part of compatible GE industrial controller bus networks.
The supplied dimensions are:
50 × 20 × 15 mm
The supplied weight is:
0.04 kg
Depending on the applicable bus architecture, it provides a physical bus connection and/or termination point required for reliable network operation.
It should be installed at the location specified by the particular bus architecture, commonly at a designated bus endpoint or termination position.
Incorrect termination can cause signal reflections, communication errors, intermittent device dropouts, and controller bus alarms.
A shared bus connection, cable, termination component, or power source can affect multiple devices simultaneously.
No. If the component does not seat correctly, verify the model, orientation, connector condition, and installation location.
| Item | Status |
|---|---|
| Correct IC697ACC702 Identified | ✓ |
| Controller Compatibility Verified | ✓ |
| Bus Architecture Confirmed | ✓ |
| Power Isolated | ✓ |
| Existing Connection Inspected | ✓ |
| Correct Installation Location Verified | ✓ |
| Terminal Plug Installed | ✓ |
| Connector Secure | ✓ |
| Bus Wiring Verified | ✓ |
| Controller Powered | ✓ |
| Network Communication Tested | ✓ |
| Diagnostics Normal | ✓ |
The GE IC697ACC702 Bus Terminal Plug is a compact but important component in compatible GE industrial automation bus networks. Its primary role is to provide the required bus connection and, where applicable, termination function that helps maintain reliable communication between controller and distributed devices.
With supplied dimensions of 50 × 20 × 15 mm and a weight of 0.04 kg, the IC697ACC702 is easy to handle and suitable for compact industrial control installations. However, its relatively small size does not reduce its importance: an incorrectly installed or missing terminal component can affect the communication performance of an entire bus segment.
For reliable operation, technicians should verify the bus architecture, installation location, connector condition, cable integrity, and termination arrangement before commissioning. During troubleshooting, physical inspection of the terminal plug and associated bus wiring should be one of the first diagnostic steps when multiple devices experience communication problems.
When correctly installed and maintained, the GE IC697ACC702 helps maintain a stable and organized bus communication network for compatible GE PLC and industrial automation systems.