| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Schneider Electric ATS48D17Q Altistart 48 Soft Starter is an industrial motor-control device designed to provide controlled starting and stopping for three-phase asynchronous motors. It is intended for fixed-speed motor applications where direct-on-line starting may result in high starting current, mechanical shock, excessive torque, or undesirable process disturbances.
As part of the Altistart 48 family, the ATS48D17Q is installed within the motor power circuit and manages the motor during acceleration and, where required, deceleration. Unlike a variable frequency drive, its primary purpose is not continuous speed regulation. Instead, it provides a controlled transition between stopped and running conditions.
The supplied dimensions of the ATS48D17Q are 275 × 160 × 190 mm, with a supplied weight of 4.9 kg. Its relatively compact form makes it suitable for integration into industrial control cabinets where controlled motor starting is required without the larger footprint of high-power soft-starter assemblies.
Typical applications include pumps, fans, conveyors, compressors, blowers, mixers, and other industrial machines using appropriately sized three-phase motors.
Correct application requires more than simply matching the starter to motor horsepower. Motor rated voltage, current, starting duty, load inertia, acceleration time, number of starts, ambient temperature, cabinet cooling, and control architecture should all be considered during selection and commissioning.
| Parameter | Specification |
|---|---|
| Manufacturer | Schneider Electric |
| Product Family | Altistart 48 |
| Model | ATS48D17Q |
| Product Type | Soft Starter |
| Motor Type | Three-Phase Asynchronous Motor |
| Main Function | Controlled Motor Starting and Stopping |
| Starting Method | Electronic Soft Start |
| Stopping Method | Controlled Soft Stop |
| Dimensions | 275 × 160 × 190 mm |
| Weight | 4.9 kg |
| Installation | Industrial Electrical Cabinet |
| Typical Applications | Pumps, Fans, Conveyors, Compressors, Blowers, Mixers |
| Control Integration | PLC / HMI / Hardwired Control |
| Thermal Management | Required |
| Technical Item | Specification |
|---|---|
| Brand | Schneider Electric |
| Series | Altistart 48 |
| Catalog Number | ATS48D17Q |
| Product Category | Electronic Soft Starter |
| Application | Three-Phase AC Motor Control |
| Starting Function | Controlled Acceleration |
| Stopping Function | Controlled Deceleration |
| Dimensions | 275 × 160 × 190 mm |
| Weight | 4.9 kg |
| Installation Environment | Industrial Control Cabinet |
| Typical Load Types | Pumps, Fans, Conveyors, Compressors, Blowers, Mixers |
| Control System | PLC / HMI / Hardwired |
| Cooling | Adequate Cabinet Ventilation Required |
| Maintenance | Electrical, Thermal, and Mechanical Inspection |
The ATS48D17Q is an electronic soft starter installed between the three-phase power supply and an appropriately selected motor.
A simplified motor-control arrangement is:
Three-Phase Supply
↓
Protection / Disconnect
↓
ATS48D17Q
↓
Three-Phase Motor
↓
Mechanical Load
When the motor receives a start command, the soft starter controls its acceleration instead of applying the full starting condition immediately.
During stopping, the starter can provide controlled deceleration when required by the application.
This operating method is particularly useful when the machine needs a smoother transition into and out of operation.
A three-phase induction motor normally draws significantly more current during startup than during steady-state operation. Direct-on-line starting can therefore place substantial demand on the electrical supply and mechanical system.
The soft starter manages the motor-starting process using power electronic control.
The simplified sequence is:
Motor Stopped
↓
Start Command
↓
Controlled Starting Condition
↓
Progressive Acceleration
↓
Motor Reaches Operating Condition
↓
Normal Running
For controlled stopping:
Stop Command
↓
Controlled Deceleration
↓
Motor Stops
The appropriate configuration depends on the motor and driven load.
The ATS48D17Q can provide a more gradual acceleration process than direct-on-line starting.
This is valuable for machinery with:
Where required, controlled stopping can reduce abrupt transitions when the motor is switched off.
A controlled starting profile can reduce sudden forces applied to:
The ATS48D17Q can be integrated into conventional hardwired control systems as well as PLC-based automation architectures.
The ATS48D17Q should not be confused with a variable frequency drive.
| Feature | ATS48D17Q Soft Starter | Variable Frequency Drive |
|---|---|---|
| Controlled Starting | Yes | Yes |
| Controlled Stopping | Yes | Yes |
| Continuous Speed Regulation | No | Yes |
| Variable Frequency | No | Yes |
| Fixed-Speed Motor | Well Suited | Suitable |
| Variable-Speed Process | Not Primary | Well Suited |
| Starting Current Control | Yes | Yes |
| Primary Function | Start / Stop Control | Speed / Torque Control |
For a machine that normally runs at one fixed speed and only requires controlled starting and stopping, a soft starter can be an efficient control solution.
Pump motors can produce hydraulic disturbances when started or stopped abruptly.
Controlled starting can help create a smoother transition.
Suitable applications may include:
Stopping behavior should also be evaluated because certain hydraulic systems are sensitive to rapid motor shutdown.
Conveyors can contain substantial mechanical inertia, especially when carrying heavy materials.
Direct starting can produce:
A controlled acceleration process can help reduce these effects.
Fans and blowers can require considerable starting effort because of rotating inertia.
Potential applications include:
The starter should be selected according to the motor and actual operating duty.
Compressors may present demanding starting conditions.
Before commissioning, evaluate:
The complete application must be considered when determining suitability.
Mixers and agitators can require substantial starting torque, especially when material is already present.
Controlled starting can reduce stress on:
Verify:
Schneider Electric ATS48D17Q
Compare the product with:
Do not assume another Altistart model is interchangeable simply because it has similar dimensions.
Inspect the ATS48D17Q for:
The starter should be inspected before connection to the electrical system.
The supplied dimensions are:
275 × 160 × 190 mm
These dimensions should be used as the equipment envelope when planning the cabinet.
Additional space should be provided for:
Do not design the enclosure with zero clearance around the equipment.
The supplied weight is:
4.9 kg
The mounting structure should safely support the starter.
Verify:
Avoid placing mechanical strain on the electrical terminals.
The soft starter generates heat during operation.
Cabinet design should consider:
Insufficient cooling can result in thermal protection or reduced equipment service life.
Evaluate the installation environment for:
Clean and adequately ventilated cabinet conditions help maintain reliable operation.
Connect the starter to the appropriate protective grounding system.
Verify:
Grounding should be checked before energizing the equipment.
Connect the incoming three-phase supply according to the approved electrical schematic.
Before energization, verify:
Connect the motor according to its actual nameplate and approved wiring diagram.
Verify:
A typical control circuit may contain:
Control wiring must correspond to the machine’s electrical design.
The ATS48D17Q can be incorporated into a PLC-controlled motor system.
A simplified architecture is:
PLC
↓
Start / Stop Logic
↓
ATS48D17Q
↓
Three-Phase Motor
↓
Machine
The PLC can control the operating sequence while the soft starter handles the motor-starting process.
Typical signals may include:
Check:
Check:
Record and confirm:
The actual motor nameplate should be used rather than assumed values.
Starting characteristics should correspond to the mechanical application.
Consider:
Start the motor under controlled conditions.
Monitor:
If acceleration is abnormal, stop the test and investigate before repeated starts.
Confirm that the motor rotates in the correct direction.
This is particularly important for:
Verify:
Gradually apply the normal operating load.
Monitor:
Check:
A control interlock can prevent operation even when the starter itself is functional.
Possible causes include:
Trace the power circuit systematically.
Potential causes:
Inspect both electrical and mechanical conditions.
Check:
A slow acceleration problem may originate from the driven machine rather than the starter.
Possible causes include:
Measure actual current during starting whenever possible.
If the expected soft-start behavior is not present, inspect:
Check:
Determine whether the abrupt stop originates from the starter or an external switching device.
Potential causes:
Possible causes include:
Potential symptoms:
Inspect:
If a pump system experiences pressure fluctuations:
If mechanical shock remains excessive:
The soft starter cannot correct mechanical defects.
Check:
Trace the command from the PLC to the starter.
Record:
Comparing these values can help identify thermal, electrical, mechanical, or process-related causes.
Inspect:
Look for:
Inspect:
Restricted airflow can gradually create thermal problems.
Inspect:
Inspect the driven machine for:
Increasing mechanical resistance can increase motor current and starter thermal loading.
After commissioning, document the final configuration.
Recommended information includes:
Keeping accurate records simplifies future troubleshooting and replacement.
When replacing an ATS48D17Q, verify the complete application.
| Selection Factor | Verification |
|---|---|
| Motor Voltage | Required |
| Motor Current | Required |
| Motor Power | Required |
| Starting Duty | Required |
| Number of Starts | Required |
| Acceleration Time | Required |
| Load Inertia | Required |
| Control Voltage | Required |
| I/O Requirements | Required |
| Communication | Required |
| Cabinet Dimensions | Required |
| Cooling | Required |
| Environmental Conditions | Required |
| Mounting | Required |
Physical dimensions alone do not establish electrical compatibility.
| Component | Typical Function |
|---|---|
| Schneider PLC | Machine control |
| HMI | Operator interface |
| Circuit Breaker | Power protection |
| Disconnect Switch | Electrical isolation |
| Contactor | Switching / bypass |
| Three-Phase Motor | Mechanical power |
| Motor Protection Device | Motor protection |
| Sensors | Process feedback |
| Control Relay | Interlocking |
| Industrial Cabinet | Equipment enclosure |
| Cooling Fan | Thermal management |
The exact components depend on the machine’s electrical architecture.
The ATS48D17Q can provide progressive motor acceleration, helping reduce abrupt electrical and mechanical loading.
Controlled starting can reduce stress on:
Controlled deceleration can reduce abrupt transitions in appropriate applications.
The supplied 275 × 160 × 190 mm dimensions and 4.9 kg weight make the ATS48D17Q suitable for compact industrial cabinet integration when its electrical rating matches the application.
The soft starter is particularly useful where the motor normally operates at a fixed speed.
The ATS48D17Q can be incorporated into PLC-controlled motor systems using the appropriate control architecture.
The ATS48D17Q is a Schneider Electric Altistart 48 electronic soft starter designed for three-phase asynchronous motor applications.
It provides controlled motor starting and stopping to reduce abrupt electrical and mechanical transitions.
The supplied dimensions are:
275 × 160 × 190 mm
The supplied weight is:
4.9 kg
No. It is a soft starter designed primarily for controlled acceleration and deceleration rather than continuous speed control.
Yes. Pumps are a common type of application for soft starters when the motor and starter are correctly matched.
Yes. Controlled acceleration can help reduce mechanical shock in suitable conveyor applications.
Check incoming power, control signals, interlocks, motor wiring, starter status, configuration, motor condition, and mechanical load.
Possible causes include excessive load, insufficient starting torque, unsuitable starting parameters, mechanical friction, or incorrect starter selection.
Check motor current, starting frequency, ambient temperature, cabinet ventilation, airflow, filters, and application sizing.
Possible causes include excessive load, frequent starts, long acceleration, mechanical friction, poor cooling, incorrect configuration, or motor faults.
Yes. The starter can be incorporated into a PLC-based industrial motor-control system using the appropriate control interface.
Verify motor voltage, current, power, starting duty, number of starts, acceleration requirements, control architecture, cabinet dimensions, cooling, and environmental conditions.
| Item | Verification |
|---|---|
| Manufacturer | Schneider Electric |
| Product Family | Altistart 48 |
| Model | ATS48D17Q |
| Product Type | Soft Starter |
| Dimensions | 275 × 160 × 190 mm |
| Weight | 4.9 kg |
| Motor Voltage | Verified |
| Motor Current | Verified |
| Motor Power | Verified |
| Cabinet Space | Verified |
| Mechanical Mounting | Verified |
| Ventilation | Verified |
| Grounding | Verified |
| Incoming Power | Verified |
| Motor Wiring | Verified |
| Control Wiring | Verified |
| PLC Interface | Verified |
| Starting Parameters | Configured |
| Stopping Parameters | Configured |
| Motor Rotation | Tested |
| Initial Start | Completed |
| Full Load Test | Completed |
| Configuration Backup | Completed |
Use the following sequence when diagnosing an ATS48D17Q installation:
Incoming Power
↓
Start / Stop Signals
↓
Interlocks
↓
Starter Status
↓
Motor Wiring
↓
Motor Current
↓
Starting Configuration
↓
Mechanical Load
↓
Cabinet Cooling
↓
Motor Condition
↓
Controlled Retest
This process helps determine whether a fault originates from the starter, power supply, PLC, motor, wiring, or driven machinery.
The Schneider Electric ATS48D17Q Altistart 48 Soft Starter is an industrial motor-control solution designed to provide controlled acceleration and stopping for appropriately selected three-phase asynchronous motors. It is particularly useful for fixed-speed machinery where direct-on-line starting can cause excessive current, mechanical shock, vibration, or process disturbances.
With supplied dimensions of 275 × 160 × 190 mm and a supplied weight of 4.9 kg, the ATS48D17Q offers a relatively compact installation footprint for industrial motor-control cabinets. Nevertheless, adequate clearance, ventilation, grounding, electrical protection, and maintenance access remain essential.
Successful installation begins with verifying the actual motor and load requirements. Motor voltage, rated current, starting duty, acceleration requirements, number of starts, environmental conditions, and cabinet thermal characteristics should all be evaluated before commissioning.
For troubleshooting, the ATS48D17Q should be considered as one part of the complete motor-control system. Starting failures, excessive current, overheating, phase-loss conditions, slow acceleration, or intermittent faults may originate from the power supply, control circuit, motor, starter configuration, PLC, or mechanical equipment.
With correct selection, installation, commissioning, thermal management, and preventive maintenance, the ATS48D17Q can provide reliable controlled motor starting and stopping for a wide range of industrial automation and fixed-speed motor applications.