• Ingersoll Rand 47704432001 47690563001 Temperature Control Valve Repair Kit
  • Ingersoll Rand 47704432001 47690563001 Temperature Control Valve Repair Kit
  • Ingersoll Rand 47704432001 47690563001 Temperature Control Valve Repair Kit
  • Ingersoll Rand 47704432001 47690563001 Temperature Control Valve Repair Kit
Product Overview The Ingersoll Rand 47690563001 Temperature Control Valve Repair Kit is a maintenance component designed for compatible oil-injected rotary screw air compressor systems. Associated with ……
Ingersoll Rand 47704432001 47690563001 Temperature Control Valve Repair Kit
  • Ingersoll Rand
  • 47704432001 47690563001
  • Temperature Control Valve Repair Kit
  • USA
  • 100 x 15 x 80 mm
  • 0.15 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 10

Our advantage

Ingersoll Rand 47704432001 47690563001 Temperature Control Valve Repair Kit

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Ingersoll Rand 47704432001 47690563001 Temperature Control Valve Repair Kit

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Ingersoll Rand 47704432001 47690563001 Temperature Control Valve Repair Kit

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Ingersoll Rand 47704432001 47690563001 Temperature Control Valve Repair Kit

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Ingersoll Rand 47690563001 Temperature Control Valve Repair Kit is a maintenance component designed for compatible oil-injected rotary screw air compressor systems. Associated with the Ingersoll Rand 47704432001 service kit, it is used to restore the operating condition of the compressor’s temperature control valve and maintain appropriate lubricant temperature during normal operation.

Temperature management is essential in an oil-injected screw compressor because the lubricant performs several functions simultaneously. It provides lubrication, removes heat from the compression process, assists with sealing between rotating components, and carries heat toward the compressor cooling system. If the lubricant temperature becomes too low or too high, compressor efficiency, lubrication quality, condensation control, and component life can be affected.

The temperature control valve regulates the flow path of compressor lubricant according to operating temperature. The 47690563001 repair kit provides replacement service components for the valve assembly, helping restore proper temperature-control performance without necessarily replacing the complete valve assembly.

The supplied dimensions are 100 × 15 × 80 mm, with a specified weight of approximately 0.15 kg.


Product Identification

Parameter Specification
Manufacturer Ingersoll Rand
Part Number 47690563001
Associated Service Kit 47704432001
Product Type Temperature Control Valve Repair Kit
Primary Function Temperature Control Valve Maintenance
Application Oil-Injected Rotary Screw Compressor
Installation Position Compressor Lubricant Temperature Control Circuit
Dimensions 100 × 15 × 80 mm
Weight 0.15 kg
Maintenance Type Repair / Component Replacement
System Function Compressor Oil Temperature Regulation

Technical Specifications

Technical Item Specification
Product Category Temperature Control Valve Repair Kit
Manufacturer Ingersoll Rand
Part Number 47690563001
Service Kit 47704432001
Dimensions 100 × 15 × 80 mm
Weight 0.15 kg
Application Industrial Rotary Screw Compressor
Controlled Medium Compressor Lubricant
Primary Function Lubricant Temperature Regulation
Installation Temperature Control Valve Assembly
Maintenance Method Valve Repair
System Role Thermal Management

Function and Working Principle

The temperature control valve manages the flow of lubricant between the compressor’s cooling circuit and the compressor lubrication circuit.

A simplified system can be represented as:

Compressor Air End

Hot Compressor Lubricant

Temperature Control Valve

↙         ↘

Oil Cooler    Bypass Flow

↘         ↙

Controlled-Temperature Lubricant

Compressor Air End

When lubricant temperature is relatively low, the valve can direct lubricant through an appropriate bypass path to help the compressor reach its normal operating temperature.

As lubricant temperature increases, the valve progressively directs more lubricant through the oil cooler. This allows excessive heat to be removed before the lubricant returns to the compressor.

The exact valve behavior depends on the compressor design and applicable control characteristics.


Why Temperature Control Is Important

Correct lubricant temperature contributes to:

  • Proper lubrication
  • Efficient heat removal
  • Stable compression
  • Reduced condensation risk
  • Improved oil separation
  • Reduced component wear
  • Stable compressor operation
  • Longer lubricant service life

A temperature control valve that sticks or responds incorrectly can therefore create several apparently unrelated compressor problems.


Typical Industrial Applications

The 47690563001 Temperature Control Valve Repair Kit is suitable for maintenance of compatible Ingersoll Rand rotary screw compressor systems used in:

  • Manufacturing
  • Automotive production
  • Chemical processing
  • Oil and gas
  • Food and beverage
  • Pharmaceutical production
  • Mining
  • Cement manufacturing
  • Power generation
  • Metalworking
  • Textile production
  • General industrial facilities

Installation and Repair Guide

1. Verify the Repair Kit

Before beginning maintenance, confirm:

Part Number: 47690563001

Associated Service Kit: 47704432001

The repair kit should only be used with a compatible temperature control valve assembly.


2. Shut Down the Compressor

Before servicing the temperature control valve:

  • Stop the compressor.
  • Disconnect electrical power.
  • Isolate the compressor.
  • Release system pressure.
  • Allow the lubricant and components to cool.
  • Apply appropriate lockout/tagout procedures.

Hot compressor oil can cause serious burns.


3. Allow the Lubricant to Cool

The temperature control valve is directly associated with the compressor lubricant circuit.

Do not open the circuit while the oil remains at an unsafe temperature.


4. Locate the Temperature Control Valve

Identify the valve within the compressor lubricant circuit.

Inspect surrounding:

  • Oil lines
  • Fittings
  • Cooler connections
  • Valve housing
  • Sealing surfaces

5. Remove the Valve Assembly

Follow the applicable compressor service procedure.

Carefully disconnect the valve without damaging:

  • Oil pipes
  • Threads
  • Housing surfaces
  • Connections
  • Adjacent components

6. Inspect the Existing Valve

Before installing repair components, inspect for:

  • Valve sticking
  • Contamination
  • Wear
  • Corrosion
  • Damaged sealing surfaces
  • Abnormal oil deposits

Determine whether the valve body itself remains suitable for reuse.


7. Disassemble the Valve

Disassemble the valve carefully and keep components organized.

Pay particular attention to:

  • Component orientation
  • Spring position
  • Sealing elements
  • Valve movement
  • Internal contamination

8. Install Repair Kit Components

Install the components supplied with the 47690563001 Temperature Control Valve Repair Kit.

Verify:

  • Correct component placement
  • Proper seating
  • Clean surfaces
  • Correct orientation
  • Free mechanical movement

Do not force internal components into position.


9. Inspect Sealing Surfaces

Before reassembly, verify that sealing surfaces are:

  • Clean
  • Smooth
  • Free from scratches
  • Free from foreign material

Damaged sealing surfaces can cause lubricant leakage.


10. Reassemble the Valve

Reassemble the valve carefully according to the compressor service procedure.

Ensure all components move correctly before installation.


11. Reinstall the Valve

Install the repaired valve into the compressor lubricant circuit.

Reconnect:

  • Oil lines
  • Fittings
  • Mounting hardware
  • Associated components

12. Restore the System

After completing the repair:

  1. Verify all connections.
  2. Confirm correct oil level.
  3. Restore electrical power.
  4. Start the compressor.
  5. Allow it to warm up.
  6. Monitor lubricant temperature.
  7. Inspect for oil leakage.
  8. Confirm stable operating conditions.

Commissioning Procedure

After repairing the temperature control valve, monitor the compressor during warm-up.

Initial Startup

Check:

  • Oil pressure
  • Oil temperature
  • Compressor loading
  • Abnormal noise
  • Oil leakage

Warm-Up

Observe whether lubricant temperature increases normally.

Normal Operation

Verify:

  • Stable operating temperature
  • Normal cooler operation
  • No excessive temperature fluctuations
  • No abnormal oil consumption

Troubleshooting Guide

Problem 1 — Compressor Oil Temperature Too High

Possible causes:

  • Temperature control valve stuck in the wrong position
  • Oil cooler restriction
  • Poor cooling airflow
  • High ambient temperature
  • Dirty cooler
  • Insufficient lubricant flow

Check the temperature control valve together with the cooling system.


Problem 2 — Compressor Oil Temperature Too Low

Possible causes:

  • Valve stuck in cooler flow position
  • Low ambient temperature
  • Excessive cooling
  • Incorrect valve operation

Low oil temperature can increase condensation risk in certain operating conditions.


Problem 3 — Oil Temperature Fluctuates

Possible causes:

  • Valve sticking
  • Contaminated valve
  • Worn internal components
  • Unstable compressor load
  • Cooling-system problems

Inspect valve movement and operating conditions.


Problem 4 — Compressor Runs Hot

Possible causes:

  • Valve malfunction
  • Restricted oil cooler
  • Insufficient cooling airflow
  • Low lubricant level
  • Incorrect lubricant

The temperature control valve should be inspected as part of the complete thermal-management system.


Problem 5 — Oil Leakage Around Valve

Possible causes:

  • Damaged seal
  • Improper reassembly
  • Scratched sealing surface
  • Loose connection
  • Incorrect installation

Inspect the repaired valve and all associated connections.


Problem 6 — Valve Sticks

Possible causes:

  • Contaminated lubricant
  • Foreign particles
  • Internal corrosion
  • Component wear
  • Incorrect assembly

Disassemble and inspect the valve if sticking is confirmed.


Problem 7 — Compressor Temperature Takes Too Long to Stabilize

Possible causes:

  • Incorrect valve operation
  • Excessive cooling
  • Low load condition
  • Environmental temperature
  • Valve response problem

Check the temperature control system before replacing unrelated components.


Problem 8 — High Lubricant Consumption

Possible causes:

  • Excessive operating temperature
  • Oil separation problems
  • Incorrect oil level
  • Oil leakage
  • Temperature-control malfunction

Inspect the temperature control valve together with the air-oil separator and oil system.


Diagnostic Workflow

Use a systematic troubleshooting sequence:

Compressor Air End

Hot Lubricant

47690563001 Temperature Control Valve

Oil Cooler / Bypass Circuit

Controlled-Temperature Lubricant

Compressor Air End

Temperature Monitoring

This sequence helps distinguish valve-related problems from cooling-system or lubrication-system faults.


Preventive Maintenance

Regular inspection of the temperature control system helps prevent unexpected compressor shutdowns.

Valve Inspection

Check:

  • Mechanical movement
  • Internal contamination
  • Wear
  • Corrosion
  • Sealing condition

Lubricant Inspection

Monitor:

  • Oil level
  • Oil cleanliness
  • Oil condition
  • Operating temperature
  • Lubricant consumption

Oil Cooler Inspection

Check:

  • Cooler cleanliness
  • Airflow
  • Oil passages
  • External contamination
  • Cooling performance

Operating Condition Inspection

Monitor:

  • Ambient temperature
  • Compressor load
  • Discharge pressure
  • Oil temperature
  • Operating hours

Preventive Maintenance Checklist

Inspection Item Recommended Action
Temperature Control Valve Inspect movement
Valve Seals Check for leakage
Internal Components Inspect for wear
Lubricant Check condition
Oil Level Maintain correct level
Oil Cooler Clean and inspect
Cooling Airflow Verify adequate flow
Oil Temperature Monitor trends
Valve Connections Check for leaks
Compressor Load Monitor operating conditions

Common Repair Errors

Installing Incorrect Components

Only compatible repair components should be installed in the valve assembly.

Incorrect Component Orientation

Internal valve components must be installed in their proper positions.

Reusing Damaged Seals

Damaged sealing elements can cause oil leakage after repair.

Contaminated Assembly

Dirt or foreign material can cause the repaired valve to stick.

Ignoring the Oil Cooler

A high oil temperature does not necessarily indicate a valve fault. Cooler blockage and inadequate airflow must also be considered.

Restarting Without Inspection

Always check the complete oil circuit before returning the compressor to service.


Key Advantages

  • Restores temperature control valve performance
  • Supports proper compressor lubricant temperature
  • Helps maintain lubrication reliability
  • Supports oil cooler and bypass operation
  • Can reduce the need for complete valve replacement
  • Helps reduce unplanned compressor downtime
  • Compact repair-kit format
  • 0.15 kg lightweight design
  • Suitable for scheduled compressor maintenance
  • Supports long-term compressor reliability

Frequently Asked Questions

What is the Ingersoll Rand 47690563001?

The 47690563001 is a temperature control valve repair kit used to service the temperature control valve in compatible Ingersoll Rand rotary screw compressors.

Which service kit is associated with this part?

It is associated with Ingersoll Rand 47704432001.

What are the dimensions?

The specified dimensions are 100 × 15 × 80 mm.

What is the weight?

Approximately 0.15 kg.

What does the temperature control valve do?

It regulates the flow path of compressor lubricant between the cooling circuit and bypass circuit to help maintain an appropriate operating temperature.

Why is oil temperature important?

Correct oil temperature supports lubrication, heat removal, stable compression, and reliable compressor operation.

What causes high compressor oil temperature?

Possible causes include a malfunctioning temperature control valve, restricted oil cooler, poor cooling airflow, insufficient lubricant, high ambient temperature, or other cooling-system problems.

What causes low oil temperature?

Possible causes include excessive cooling, incorrect valve operation, low ambient temperature, or a valve stuck in an inappropriate position.

Should the complete valve be replaced if it malfunctions?

Not necessarily. Where the valve body remains serviceable, a suitable repair kit can restore worn or damaged service components.

What should be checked after repairing the valve?

Monitor oil temperature, oil level, cooling performance, compressor loading, leakage, and overall operating stability after startup.


Conclusion

The Ingersoll Rand 47690563001 Temperature Control Valve Repair Kit is an important maintenance solution for compatible oil-injected rotary screw compressors. With specified dimensions of 100 × 15 × 80 mm and a weight of approximately 0.15 kg, the kit is designed to restore the performance of the compressor’s temperature control valve and help maintain proper lubricant temperature.

Because compressor lubricant performs critical lubrication and cooling functions, reliable temperature regulation is essential for long-term equipment performance. A properly functioning temperature control valve helps balance cooler and bypass flow, preventing excessive lubricant temperatures while also reducing the risk of operating with oil that is too cold.

Correct repair procedures, clean assembly, proper sealing, and post-maintenance temperature monitoring are essential. Regular inspection of the valve, lubricant, oil cooler, and cooling circuit can further reduce unexpected failures and help maintain efficient, stable compressor operation.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501