• GE IC695PNS001CA PACSystems RX3i PROFINET Scanner Module
  • GE IC695PNS001CA PACSystems RX3i PROFINET Scanner Module
  • GE IC695PNS001CA PACSystems RX3i PROFINET Scanner Module
  • GE IC695PNS001CA PACSystems RX3i PROFINET Scanner Module
Product Overview The GE IC695PNS001CA PACSystems RX3i PROFINET Scanner Module is a network communication module used in GE PACSystems RX3i PLC platforms to provide PROFINET connectivity between the cont……
GE IC695PNS001CA PACSystems RX3i PROFINET Scanner Module
  • GE
  • IC695PNS001CA
  • PROFINET Scanner Module
  • USA
  • 150 × 35.6 × 125 mm
  • 0.513 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 16

Our advantage

GE IC695PNS001CA PACSystems RX3i PROFINET Scanner Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE IC695PNS001CA PACSystems RX3i PROFINET Scanner Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE IC695PNS001CA PACSystems RX3i PROFINET Scanner Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE IC695PNS001CA PACSystems RX3i PROFINET Scanner Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE IC695PNS001CA PACSystems RX3i PROFINET Scanner Module is a network communication module used in GE PACSystems RX3i PLC platforms to provide PROFINET connectivity between the control system and distributed field devices.

As a PROFINET Scanner Module, the IC695PNS001CA enables the RX3i controller system to communicate with PROFINET-based I/O devices, remote stations, and industrial network components. It extends the PLC architecture by adding high-speed Ethernet-based communication capability for modern automation applications.

Unlike traditional I/O modules that directly process field signals, the PROFINET Scanner Module focuses on network-level data exchange. It manages communication between the RX3i controller and connected PROFINET devices, allowing distributed automation equipment to exchange process data with the main control system.

The module is commonly used in machine automation, manufacturing systems, and industrial production lines where reliable PROFINET communication and distributed I/O integration are required.


Technical Specifications

Parameter Specification
Manufacturer GE
Model IC695PNS001CA
Product Family PACSystems RX3i
Product Type PROFINET Scanner Module
Communication Interface PROFINET / Industrial Ethernet
Primary Function PROFINET Network Communication
System Application PLC Distributed I/O Control
Installation PACSystems RX3i Rack System
Dimensions 150 × 35.6 × 125 mm
Weight 0.513 kg

Product Features

The GE IC695PNS001CA PACSystems RX3i PROFINET Scanner Module provides network integration capability for industrial automation systems.

Key characteristics include:

  • GE PACSystems RX3i PROFINET Scanner Module
  • Model IC695PNS001CA
  • Supports PROFINET-based device communication
  • Integrates distributed I/O into RX3i control systems
  • Provides Ethernet-based industrial networking capability
  • Supports modular automation system expansion
  • Connects PLC controllers with remote field devices
  • Suitable for modern industrial communication architectures
  • Supports replacement and expansion of existing RX3i systems
  • Designed for industrial automation environments

The module selection should consider network topology, connected PROFINET devices, controller configuration, and application requirements.


Working Principle

The IC695PNS001CA operates as a communication bridge between the PACSystems RX3i controller platform and PROFINET field devices.

A simplified communication path is:

RX3i Controller → PROFINET Scanner Module → Industrial Ethernet Network → Remote I/O Devices

During operation, the module exchanges process data between the PLC control system and connected PROFINET devices. It manages network communication, transfers input data from remote devices to the controller, and sends output information from the PLC program back to field equipment.

The scanner module allows distributed devices to operate as part of a unified automation system, reducing the need for extensive point-to-point wiring and supporting flexible system layouts.


Role in PACSystems RX3i Control Architecture

The IC695PNS001CA operates within the communication layer of the GE PACSystems RX3i automation architecture.

A typical system structure can be represented as:

Engineering Software → RX3i CPU → PROFINET Scanner Module → Remote I/O → Field Devices

System Layer Typical Function
RX3i CPU Executes PLC control logic
PROFINET Scanner Module Manages network communication
PROFINET Remote I/O Collects and outputs field signals
Ethernet Network Transfers automation data
Field Devices Provide process information and receive commands
Engineering Tools Configure and maintain the control system

The module does not replace the PLC CPU or execute application programs. Its main role is providing communication access between the controller and distributed network devices.


Industrial Applications

The GE IC695PNS001CA PACSystems RX3i PROFINET Scanner Module is suitable for industrial systems requiring distributed PROFINET communication.

Application Typical Use
Factory Automation Connecting distributed I/O stations
Machine Manufacturing Integrating remote control devices
Packaging Systems Supporting network-based automation
Production Lines Expanding PLC communication capability
Material Handling Connecting distributed field equipment
Process Equipment Data exchange between control stations
Industrial Ethernet Systems PROFINET network integration
Legacy PLC Upgrades Expanding RX3i communication functions

The actual application depends on the PLC configuration, network design, and connected PROFINET devices.


Installation and Maintenance

Correct network configuration and installation are important for maintaining stable communication performance.

Recommended maintenance checks include:

  • Confirm the correct IC695PNS001CA model.
  • Verify compatibility with the PACSystems RX3i platform.
  • Check rack installation position.
  • Confirm PROFINET network configuration.
  • Verify device names and network parameters.
  • Inspect Ethernet cable connections.
  • Check connector conditions.
  • Monitor communication diagnostics.
  • Verify connected remote I/O status.
  • Check controller configuration.
  • Record network topology information.
  • Test communication after replacement.

If communication faults occur, troubleshooting should include the scanner module, Ethernet cables, network switches, device configuration, remote I/O status, and PLC program settings.


Related Components

The IC695PNS001CA works together with various PACSystems RX3i automation components.

Component Function
GE PACSystems RX3i CPU Executes PLC application logic
PROFINET Scanner Module Provides network communication
Remote I/O Modules Acquire and output field signals
Ethernet Switches Support industrial network connections
Communication Modules Expand system connectivity
Power Supply Modules Provide rack power
Engineering Software Configure PLC hardware and programs
Field Devices Exchange process information

These components form a complete distributed industrial automation network.


Recommended Related Models

Model / Product Family Product Type Typical Application
GE IC695PNS001CA PACSystems RX3i PROFINET Scanner Module PROFINET device integration
GE IC695PNC001 PACSystems RX3i PROFINET Controller Module PROFINET network control
GE IC695ETM001 Ethernet Interface Module Industrial Ethernet communication
GE PACSystems RX3i Communication Modules Network Expansion Modules PLC system networking
GE RX3i I/O Modules Modular I/O Hardware Field signal processing
GE RX3i CPU Modules PLC Controller Modules Automation program execution

Selection should be based on network requirements, controller type, communication protocol, and existing PACSystems RX3i architecture.


Key Advantages

  • GE PACSystems RX3i communication component
  • Provides PROFINET network integration capability
  • Supports distributed I/O architectures
  • Connects PLC systems with Ethernet-based devices
  • Enables flexible automation system layouts
  • Integrates with existing RX3i platforms
  • Supports industrial communication expansion
  • Simplifies connection of remote field equipment
  • Suitable for machine and process automation
  • Supports long-term PLC system maintenance

Technical FAQs

How does the IC695PNS001CA improve an RX3i automation system?

The module adds PROFINET scanner capability to the RX3i platform, allowing the controller to exchange process data with distributed PROFINET devices and remote I/O stations.

What type of network devices can be integrated through this module?

The module is typically used with compatible PROFINET devices, including distributed I/O stations and industrial Ethernet-based automation components.

What factors affect communication stability when using the IC695PNS001CA?

Network configuration, Ethernet cable quality, device parameters, topology design, and correct PLC hardware configuration all influence communication performance.

When is a PROFINET Scanner Module preferred over traditional point-to-point wiring?

A scanner module is useful when an automation system requires distributed device connections, flexible network expansion, and reduced field wiring complexity.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501