• Ingersoll Rand 47552954001 23332588 Thermal Actuator
  • Ingersoll Rand 47552954001 23332588 Thermal Actuator
  • Ingersoll Rand 47552954001 23332588 Thermal Actuator
  • Ingersoll Rand 47552954001 23332588 Thermal Actuator
Product Overview The Ingersoll Rand 47552954001 23332588 Thermal Actuator is a temperature-responsive mechanical component used in the thermal control circuit of compatible Ingersoll Rand compressor sys……
Ingersoll Rand 47552954001 23332588 Thermal Actuator
  • Ingersoll Rand
  • 47552954001 23332588
  • Thermal Actuator
  • USA
  • 100 × 70 × 70 mm
  • 2.29 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 10

Our advantage

Ingersoll Rand 47552954001 23332588 Thermal Actuator

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Ingersoll Rand 47552954001 23332588 Thermal Actuator

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Ingersoll Rand 47552954001 23332588 Thermal Actuator

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Ingersoll Rand 47552954001 23332588 Thermal Actuator

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Ingersoll Rand 47552954001 23332588 Thermal Actuator is a temperature-responsive mechanical component used in the thermal control circuit of compatible Ingersoll Rand compressor systems. It works with the compressor’s temperature control valve to regulate the flow of lubricating oil according to temperature conditions.

In an oil-injected screw compressor, lubricating oil continuously circulates through the compression and cooling system. The oil needs to remain within a suitable temperature range to maintain effective cooling, sealing, and lubrication. The thermal actuator responds to temperature changes and influences the position of the associated temperature control valve.

This component is particularly relevant during compressor maintenance when the temperature regulation assembly requires inspection or repair. A properly functioning thermal actuator helps the oil circuit respond correctly as compressor operating conditions change.


Technical Specifications

Parameter Specification
Manufacturer Ingersoll Rand
Part Number 47552954001
Component Number 23332588
Product Type Thermal Actuator
Application Compressor Temperature Control
Main Function Temperature-Responsive Valve Actuation
System Lubricating Oil Cooling Circuit
Dimensions 100 × 70 × 70 mm
Weight 2.29 kg

Main Features

The 23332588 Thermal Actuator is a functional element within the compressor temperature control assembly.

Key features include:

  • Intended for compatible Ingersoll Rand compressor systems
  • Temperature-responsive actuation
  • Works with the compressor oil temperature control circuit
  • Supports automatic regulation of oil flow
  • Helps maintain appropriate lubricant operating temperature
  • Suitable for temperature control valve maintenance
  • Supports preventive and corrective compressor service
  • Compact mechanical actuator construction
  • Designed for continuous-duty compressor applications

The actuator works as part of the valve assembly rather than independently controlling compressor temperature.


Working Principle

The thermal actuator responds mechanically to changes in temperature and transfers this response to the temperature control valve.

Typical control path:

Compressor Oil → Temperature Change → Thermal Actuator → Temperature Control Valve → Oil Cooler / Bypass

During operation:

  1. Lubricating oil absorbs heat generated during compression.
  2. The oil temperature changes according to compressor load and cooling conditions.
  3. The thermal actuator responds to the temperature change.
  4. Its movement changes the position of the associated temperature control mechanism.
  5. The oil flow is directed through the appropriate cooling or bypass path.
  6. Conditioned oil returns to the compressor lubrication circuit.

This temperature-responsive mechanism allows the compressor’s oil circuit to adapt to changing operating conditions without requiring constant manual adjustment.


Role in the Compressor Temperature Control System

The thermal actuator works together with several components in the compressor oil circuit.

Component Function
Thermal Actuator Responds to oil temperature
Temperature Control Valve Regulates oil flow path
Oil Cooler Removes heat from lubricant
Oil Filter Removes contaminants from oil
Compressor Element Generates compressed air and heat
Oil Circuit Circulates lubricant through the system

The actuator and temperature control valve form an important part of the compressor’s thermal management arrangement.


Industrial Applications

Industry Typical Application
Manufacturing Screw compressor maintenance
Automotive Factory compressed-air systems
Chemical Processing Process compressor systems
Food & Beverage Plant air compressors
Textile Continuous-duty compressors
General Industry Compressor thermal control
Process Automation Utility air equipment

The 23332588 is most relevant to maintenance of compressor systems where accurate oil temperature regulation is required.


Maintenance Considerations

A thermal actuator should be inspected when compressor oil temperature does not respond normally to changes in operating conditions.

Maintenance checks may include:

  • Inspecting the actuator for mechanical damage
  • Checking actuator movement
  • Inspecting the associated temperature control valve
  • Checking oil flow through the cooler
  • Examining sealing surfaces for leakage
  • Checking compressor operating temperature
  • Verifying temperature regulation after installation

If the actuator is replaced, the associated valve assembly should also be inspected to ensure that mechanical movement is not restricted.


Compatible System Components

The 47552954001 23332588 Thermal Actuator can be used in conjunction with:

Component Function
Ingersoll Rand Temperature Control Valve Regulates oil flow
47552954001 Maintenance Components Supports valve servicing
Oil Cooler Removes heat from compressor oil
Oil Filter Maintains lubricant cleanliness
Air-Oil Separator Separates oil from compressed air
Compressor Control System Monitors operating conditions

Recommended Related Models

Model Product Type Application
Ingersoll Rand 47552954001 23332588 Thermal Actuator Compressor temperature regulation
Ingersoll Rand 47588564001 47552954001 Temperature Control Valve Maintenance Kit Valve servicing
Ingersoll Rand 47588564001 23708423 Air-Oil Separator Oil/air separation
Ingersoll Rand 47588564001 38034914 Motor Bearing Grease Motor bearing lubrication
Ingersoll Rand 47588564001 47553880001 Inlet Valve Repair Kit Compressor inlet valve service

The actuator should be selected according to the specific temperature control valve and compressor configuration.


Key Advantages

  • Responds automatically to temperature changes
  • Supports compressor oil temperature regulation
  • Helps control oil flow through cooling and bypass paths
  • Works with the temperature control valve assembly
  • Supports stable compressor lubrication conditions
  • Suitable for compressor maintenance and repair
  • Helps maintain consistent thermal management
  • Compact mechanical design for valve assembly installation

Technical FAQs

What is the Ingersoll Rand 23332588 Thermal Actuator used for?

The 23332588 is a thermal actuator used in the compressor temperature control system to respond to temperature changes and regulate the associated oil-flow control mechanism.

How does the thermal actuator affect compressor oil temperature?

It does not cool the oil directly. Instead, it responds to temperature changes and influences the temperature control valve, which determines whether oil follows the cooling or bypass path.

What symptoms may indicate a faulty thermal actuator?

Abnormal oil temperature, poor temperature regulation, or a temperature control valve that does not respond correctly may indicate a problem with the thermal actuator or related valve components.

Is the thermal actuator part of the temperature control valve assembly?

Yes. The actuator functions as part of the temperature regulation mechanism and works with the associated temperature control valve to manage lubricant flow.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501