Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Schneider ATS01N232QN Soft Starter for Asynchronous Motor is a compact motor starting device designed to provide a controlled acceleration process for three-phase asynchronous motors. It belongs to the Schneider Altistart 01 family and is intended for machines where the motor normally runs at a fixed speed but requires a smoother starting sequence.
Direct-on-line starting can produce a sharp increase in motor current and a sudden torque response. For equipment connected through belts, couplings, shafts, gearboxes, pumps, or fans, this sudden response can create unnecessary mechanical stress and vibration.
The ATS01N232QN addresses this part of the motor operating cycle by progressively controlling the voltage applied to the motor during startup. Instead of moving immediately from zero speed to a full starting condition, the motor accelerates in a more gradual manner.
This type of soft starter is useful when the application needs controlled motor starting without the continuous speed regulation and frequency control provided by a variable frequency drive.
With dimensions of 154 × 45 × 131 mm and a stated weight of 0.56 kg, the ATS01N232QN maintains a narrow 45 mm width while providing a compact form factor for industrial control cabinet installation.
| Parameter | Details |
|---|---|
| Manufacturer | Schneider Electric |
| Model | ATS01N232QN |
| Product Type | Soft Starter |
| Product Family | Altistart 01 |
| Application | Asynchronous Motor |
| Motor Type | Three-Phase Asynchronous Motor |
| Main Function | Controlled Motor Starting and Stopping |
| Starting Method | Controlled Voltage Ramp |
| Application Type | Fixed-Speed Motor Applications |
| Installation | Industrial Control Cabinet |
| Dimensions | 154 × 45 × 131 mm |
| Weight | 0.56 kg |
| Application Area | Industrial Motor Control |
The ATS01N232QN provides a straightforward approach to controlling motor acceleration and is intended for applications that do not require full variable-speed drive functionality.
Key features include:
The narrow enclosure is useful when several motor control devices, protection components, and terminal blocks need to be arranged within a limited cabinet width.
The ATS01N232QN controls the voltage applied to the asynchronous motor during the starting sequence.
After receiving a start command, the soft starter begins the acceleration process under controlled voltage conditions. The applied voltage is progressively increased, allowing the motor to develop speed in a controlled manner.
The basic process includes:
For applications that require controlled stopping, the voltage can also be reduced progressively during the stopping sequence.
This operating method can be useful where direct-on-line starting causes excessive vibration, belt movement, pressure fluctuations, or mechanical shock.
The ATS01N232QN is normally positioned within the motor starting and switching section of an industrial control system.
| Function | Description |
| Motor Starting | Provides controlled acceleration from standstill |
| Motor Stopping | Supports gradual stopping where applicable |
| Current Response Management | Helps reduce the abrupt electrical response of direct starting |
| Torque Management | Makes torque development more gradual |
| Motor Control | Supports soft starting of fixed-speed motors |
| System Integration | Works with protection and switching components |
The soft starter is not a complete motor protection system. Circuit protection, overload protection, isolation, and switching functions should be provided by appropriately selected external or associated components.
The ATS01N232QN can be used on industrial equipment where controlled acceleration is beneficial and continuous motor speed adjustment is not required.
| Industry | Typical Applications |
| Manufacturing | Production and processing machinery |
| Water Treatment | Pumps and circulation equipment |
| HVAC | Fans and ventilation systems |
| Material Handling | Conveyors and belt-driven equipment |
| Packaging | Packaging machinery |
| Process Industry | Pumps and auxiliary machinery |
| Building Services | Fans and circulation pumps |
| General Industry | Fixed-speed motor-driven machines |
A controlled startup can be particularly useful on conveyor systems, where abrupt acceleration can place additional tension on belts and mechanical couplings.
Before installing the ATS01N232QN, the motor, electrical supply, driven equipment, and protection system should be considered as a complete installation.
Recommended installation steps include:
The acceleration requirements should be evaluated against the mechanical characteristics of the driven load. A high-inertia machine can require a different startup profile from a lightly loaded fan or pump.
The ATS01N232QN is generally integrated with several components to create a complete motor control system.
| Compatible Component | Function |
| Asynchronous Motor | Main motor controlled by the soft starter |
| Circuit Breaker | Provides upstream short-circuit protection |
| Contactor | Provides switching and isolation |
| Overload Relay | Protects the motor against overload conditions |
| Motor Disconnect | Allows safe electrical isolation |
| PLC | Provides automatic start and stop commands |
| Control Relay | Provides control signals |
| Control Power Supply | Supplies the control circuit |
| Motor Protection Device | Provides additional motor protection |
The final configuration should be based on the motor’s electrical data and the requirements of the driven machine.
| Model | Type | Key Feature | Application |
| Schneider ATS01N206QN | Soft Starter | Compact controlled starting | Fixed-speed motor applications |
| Schneider ATS01N209QN | Soft Starter | Controlled motor acceleration | Pumps and conveyors |
| Schneider ATS01N212QN | Soft Starter | Compact motor starting | Industrial equipment |
| Schneider ATS01N222QN | Soft Starter | Higher-capacity soft starting | Industrial machinery |
| Schneider ATS01N232QN | Soft Starter | Controlled starting for larger applications | Motor-driven industrial equipment |
Alternative selection should not be based on model number or enclosure size alone. Motor current, supply voltage, motor power, starting frequency, load inertia, acceleration requirements, protection coordination, and control method all need to be evaluated.
The ATS01N232QN primarily addresses the abrupt electrical and mechanical response that can occur when an asynchronous motor is started directly across the supply. By controlling the voltage ramp, it allows the motor to accelerate more progressively.
Selection should begin with the motor’s rated current and supply voltage, followed by evaluation of the mechanical load, starting frequency, acceleration requirements, and operating conditions. Conveyor inertia and pump characteristics can significantly influence the required starting behavior.
No. A soft starter is primarily intended to control the motor during starting and, where supported by the application, stopping. If the machine requires different operating speeds during normal production, a variable frequency drive is generally the more appropriate technology.
An undersized soft starter may experience excessive electrical or thermal stress during acceleration and may not provide the required starting performance. The selection should therefore be based on the motor’s rated current, duty cycle, starting conditions, and driven load rather than physical dimensions alone.