To tatou painga
Nga Raraunga o te Ao
He 10 tau te roa o a maatau ki te whakaputa i te whakaaetanga mahi tahi, na reira ka tukuna a maatau hua ki nga waahi katoa o te ao.
He hou me te taketake
Ko o tatou hua he mea kawemai i te nuinga o te waahi mai i te waahi takenga mai. Na te hononga mahi tahi, he mea taketake katoa a maatau hua me te 100% hou.
24-haora ratonga
Ka whakaratohia e matou he ratonga 7 * 24 haora ki o taatau kaihoko. Ka noho matou ki reira i nga wa e hiahia ana koe.
Te painga utu
He tino pai te utu o a maatau hua katoa na te mea kei a maatau ake te whare putunga me te tuku.
Mōhiohio Company | |||
īmēra | sales@xm-automation.com | ||
Mobile | + 8613620394314 | ||
+ 8613620394314 | |||
13620394314 |
te Yokogawa AAT141-S00 is an isolated TC/mV input module designed to accurately convert thermocouple and millivolt signals into digital data for distributed control systems. Built for high signal integrity, this module features galvanic isolation between input channels and the bus, minimizing ground-loop interference. Its robust design ensures stable performance even in electrically noisy environments, making it a reliable choice for precise temperature and low-level voltage measurements in industrial processes.
te AAT141-S00 is deployed across a variety of industries and scenarios, including:
Nga Tipu matū me te matū: Temperature monitoring in reactors, distillation columns, and heat exchangers.
Mana Whakahaere: Boiler and turbine temperature control for efficient power production.
Oil & Gas: Pipeline temperature measurement and safety monitoring in remote installations.
Kai me te Inu: Precise thermal control during cooking, pasteurization, and sterilization processes.
Hanga Taputai: Validation of temperature profiles in critical production steps.
Wehenga Galvanic: Provides up to 2 kV isolation between input channels and bus, preventing ground-loop errors and enhancing safety.
Teitei Tika: Typical accuracy better than ±0.1 % of span ensures reliable data for tight control loops.
Awhe Tāuru Whānui: Supports most common thermocouple types (K, J, T, E, N, R, S, B) and ±50 mV DC signals.
Fast Conversion: Update rate of 100 ms per channel allows responsive control and monitoring.
Tapuwae Kiato: Slim module profile saves rack space while maintaining full functionality.
Brand: Yokogawa
tawhā | taipitopito |
---|---|
tauira | AAT141-S00 |
Momo Whakauru | Thermocouple (K, J, T, E, N, R, S, B) / ±50 mV DC |
hongere | 8 nga hongere whakauru motuhake |
Ngaohiko Motuhake | 2 kV AC (input-to-bus) |
tika | ±0.1 % o te whanganga |
Te Wae Hurihuri | 100 ms mo ia hongere |
Awhe Temperature | –40 ° C ki te +85 ° C |
Whakaoranga Mana | 1.8 W |
ekeeke | DIN-rail or rack-mounted |
ahu | 107.5 × 32.8 × 130 mm |
Taumaha | 0.2 kg |
Tau tauira | Whakaahuatanga | hongere | Momo Whakauru | Mahinga (mm) | Taumaha (kg) |
---|---|---|---|---|---|
AAT141-S01 | TC/mV Input Module, high-speed | 8 | Thermocouple / ±50 mV DC | 107.5 × 32.8 × 130 | 0.2 |
AAT142-S00 | Universal Input (TC, RTD, mA, V) | 8 | TC, RTD, ±50 mV, 0–20 mA | 107.5 × 32.8 × 130 | 0.2 |
AAT143-S00 | RTD/mV Input Module | 8 | RTD (Pt100/PT1000) / ±50 mV | 107.5 × 32.8 × 130 | 0.2 |
AAT144-S00 | Thermocouple Input with Cold-Junction | 4 | K, J, T, E, N | 107.5 × 32.8 × 130 | 0.2 |
AAT131-S00 | Isolated Voltage Input Module | 8 | ±10 V DC | 107.5 × 32.8 × 130 | 0.2 |
Tau tauira | Whakaahuatanga | hongere | Momo Whakauru | Mahinga (mm) | Taumaha (kg) |
---|---|---|---|---|---|
AAI132-S00 | Kōwae Whakauru RTD | 8 | Pt100/Pt1000 RTD | 107.5 × 32.8 × 130 | 0.2 |
AAI141-S00 | 4–20 mA Kōwae Whakauru | 8 | 0–20 mA DC | 107.5 × 32.8 × 130 | 0.2 |
AAB142-S00 | Ngaohiko Putanga Kōwae | 8 | 0–10 V DC | 107.5 × 32.8 × 130 | 0.2 |
AAF141-S00 | Kōwae Putanga o nāianei | 8 | 4–20 mA DC | 107.5 × 32.8 × 130 | 0.2 |
AAD321-S00 | Waehere Ranu Whakauru/Putanga o te Ao | 4 IN / 4 WAHO | TC, RTD, mA, V | 107.5 × 65.6 × 130 | 0.35 |
Q: What thermocouple types does AAT141-S00 tautoko?
A: It supports types K, J, T, E, N, R, S, and B.
Q: How many isolated channels are available?
A: There are 8 galvanically isolated input channels.
Q: What is the maximum input voltage for mV signals?
A: Up to ±50 mV DC per channel.
Q: What level of isolation does the module provide?
A: 2 kV AC isolation between each input channel and the bus.
Q: What is the conversion speed per channel?
A: 100 ms per channel.
Q: Can this module operate in harsh environments?
A: Yes, it operates reliably from –40 °C to +85 °C.
Q: Me pehea te whakauru o te kōwae?
A: It can be DIN-rail or rack-mounted.
Q: What is the typical accuracy?
A: Better than ±0.1 % of span.
Q: He aha nga rahinga tinana o te kōwae?
A: 107.5 × 32.8 × 130 mm.
Q: How much power does it consume?
A: Tata ki te 1.8 W.
Taurangi motuhēhē
Ko nga korero katoa he hua taketake me nga hua kawemai. He 300 miriona yuan te rahinga hoko a-tau, a ka whakaputahia e matou nga hua taketake me te pono. Ka taea e nga kaihoko katoa e mahi tahi ana ki a maatau i runga ipurangi ka parekareka ki nga utu iti.
Whare putunga kore utu
Kei a matou he momo tauira hua katoa, 80% o nga tauira tikanga kei roto i nga taonga, a kua whakaturia e matou nga waahana i Ahia, Awherika, Amerika Te Tai Tokerau, Amerika ki te Tonga, me Uropi, me te whakaiti i te wa tukatuka ota me te makona i nga kaihoko i te wa tika.
Roopu Hangarau
Te tuku tere. Ka taea te tukuna nga taonga waahi i te ra kotahi, a ko te whakawhitinga wa tuku he 20% tere atu i nga hoa i te toharite, me te tere o te wa tuku o te 99%.
Ratonga whai muri-hoko
24-haora i muri i-hoko te roopu taurangi ratonga, te punaha ratonga whakahaere ngaio me te paerewa.