te Honeywell FS-TSAI-0410 is a high-performance safety analog input module designed for use in safety instrumented systems. Built on fault-tolerant architecture (FTA), it provides reliable and precise analog input signal processing for critical applications requiring SIL (Safety Integrity Level) certification. The module supports various sensor inputs, including 4–20 mA signals, ensuring compatibility with a wide range of industrial transmitters and sensors. Compact in size, it offers easy integration into safety racks, delivering enhanced diagnostics and fault detection capabilities essential for maintaining system integrity.
tawhā | Whakapūtātanga |
---|---|
Tau tauira | FS-TSAI-0410 |
Momo Module | Safety Analog Input Module (FTA) |
Channels whakauru | 4 |
Momo Tohu Whakauru | 4–20 mA, 0–20 mA |
Rangi Whakauru | 0–20 mA nominal |
tika | ±0.1% o te whanganga |
Resolution | 14-bit ADC |
Wā urupare | ≤ 50 ms |
Hangahanga Whakaaetanga Hapa | Dual-redundant channel design |
Taumata o te Haumaru Haumaru | SIL 3 whaimana |
Mahinga (W × H × D) | 60 × 70 × 58 mm |
Taumaha | 0.6 kg |
ekeeke | Rino tereina |
Temperature Whakahaere | –25 ° C ki te +70 ° C |
Certifications | IEC 61508 SIL 3, CE, UL |
Designed for critical industrial process control, this module is widely used in safety instrumented functions such as pressure and temperature transmitter input monitoring, flow control systems, level detection in tanks, and other safety-related analog signal monitoring in oil & gas, chemical plants, pharmaceuticals, and power generation industries.
High precision 14-bit ADC provides accurate and stable readings, fault-tolerant dual-channel architecture guarantees uninterrupted safety operation, certified for SIL 3 ensuring compliance with stringent safety standards, compact form factor for efficient use of rack space, and comprehensive diagnostics enhance preventive maintenance and reduce downtime.
Honeywell is a globally respected leader in industrial automation and safety systems, providing robust and certified safety modules tailored for critical process control environments worldwide.
tauira | momo | hongere | Mahinga (mm) | Taumaha (kg) |
---|---|---|---|---|
FS-TSAI-0810 | Safety Analog Input Module (FTA) | 8 | 120 × 70 × 58 | 1.2 |
FS-TSAO-0410 | Safety Analog Output Module (FTA) | 4 | 60 × 70 × 58 | 0.6 |
FS-TADI-0410 | Analog Input Dual Redundant Module | 4 | 60 × 70 × 58 | 0.6 |
FS-TSDI-1648 | Haumaru Mamati Whakauru Kōwae | 16 | 90 × 70 × 58 | 0.3 |
FS-TADO-0410 | Whakataurite Putanga FTA Kōwae | 4 | 60 × 70 × 58 | 0.6 |
tauira | momo | taumahi | Mahinga (mm) | Taumaha (kg) |
---|---|---|---|---|
FC-TSDI-1648 | Haumaru Mamati Whakauru Kōwae | 16 whakauru | 90 × 70 × 58 | 0.3 |
FC-TSDO-1648 | Haumaru Mamati Whakaputa Kōwae | 16 putanga | 90 × 70 × 58 | 0.3 |
FS-TSDO-0810 | Haumaru Mamati Whakaputa Kōwae | 8 putanga | 120 × 70 × 58 | 0.7 |
FC-TSRO-0808 | Kore Whakaputa Relay Haumaru | 8 putanga rei | 90 × 70 × 58 | 0.3 |
FS-TALS-1008 | Kōwae Rere Haumaru | 8 putanga | 90 × 70 × 58 | 0.28 |
Q1: He aha nga momo tohu ka mahia e te FS-TSAI-0410 whakaae?
A1: It accepts 4–20 mA and 0–20 mA analog current signals from field transmitters.
Q2: E hia nga waahana whakauru e tautokohia ana e te kōwae?
A2: The module supports 4 analog input channels.
Q3: Is this module suitable for safety applications?
A3: Yes, it is certified to SIL 3 for safety-critical applications.
Q4: What kind of fault tolerance does it have?
A4: It uses a dual-redundant channel architecture to ensure fault tolerance.
Q5: Ka taea e te kōwae te kite i nga hapa waea?
A5: Yes, it provides diagnostic features including open and short circuit detection.
Q6: What is the typical response time for inputs?
A6: The input response time is typically less than or equal to 50 milliseconds.
Q7: What operating temperature range does it support?
A7: It supports operating temperatures from –25 °C to +70 °C.
Q8: Me pehea te whakauru o te kōwae?
A8: Kua hangaia mo te DIN rail whakapuru.
Q9: He aha te tika o te kōwae?
A9: The module provides ±0.1% of span accuracy.
Q10: He aha nga ahumahi e whakamahi ana i tenei waahanga?
A10: It is used in oil & gas, chemical processing, pharmaceuticals, power generation, and other process industries requiring safety instrumentation.
Taurangi motuhēhē
Ko nga korero katoa he hua taketake me nga hua kawemai. He 300 miriona yuan te rahinga hoko a-tau, a ka whakaputahia e matou nga hua taketake me te pono. Ka taea e nga kaihoko katoa e mahi tahi ana ki a maatau i runga ipurangi ka parekareka ki nga utu iti.
Whare putunga kore utu
Kei a matou he momo tauira hua katoa, 80% o nga tauira tikanga kei roto i nga taonga, a kua whakaturia e matou nga waahana i Ahia, Awherika, Amerika Te Tai Tokerau, Amerika ki te Tonga, me Uropi, me te whakaiti i te wa tukatuka ota me te makona i nga kaihoko i te wa tika.
Roopu Hangarau
Te tuku tere. Ka taea te tukuna nga taonga waahi i te ra kotahi, a ko te whakawhitinga wa tuku he 20% tere atu i nga hoa i te toharite, me te tere o te wa tuku o te 99%.
Ratonga whai muri-hoko
24-haora i muri i-hoko te roopu taurangi ratonga, te punaha ratonga whakahaere ngaio me te paerewa.