ʻO ko mākou pono
Hoʻonohonoho honua
Loaʻa iā mākou he 10 mau makahiki logistic a hōʻike i ka ʻaelike hui, no laila hiki ke hoʻouna ʻia kā mākou huahana i nā wahi āpau o ka honua.
Mea hou a kumu
Hoʻokomo ʻia kā mākou huahana i ka nui mai kahi i kumu. Ma muli o ka pilina pili, ʻo kā mākou huahana nā mea a pau a 100% hou.
24-hola lawelawe
Hāʻawi mākou i nā hola 7 * 24 i kā mākou mea kūʻai. Aia mākou ma laila i kēlā me kēia manawa āu e pono ai iā mākou.
ʻO ke kumu kūʻai
Kūʻai maikaʻi ʻia kā mākou huahana āpau no ka mea aia kā mākou hale kūʻai ponoʻī a me ka lako.
Company Information | |||
sales@xm-automation.com | |||
Mobile | 8613620394314 + | ||
8613620394314 + | |||
KuAi | 13620394314 |
aiao | hoakaka |
---|---|
Brand | Emerson |
Series | DeltaV |
Model Number | KJ3225X1-BA1 12P4174X042 |
ʻAno hoʻokomo | RTD/Ke kū'ē |
Ka helu o nā kaha | 16 |
Laulā komo | Kākoʻo i nā ʻano RTD he nui |
pololei | ʻO ke ana pololei kiʻekiʻe |
hooholo | 16-bit |
kamaʻilio | ʻO ka ʻōnaehana DeltaV kūpono |
Lako ikehu | 24V DC |
pae'ōnaehana Mahana | -40 ° C a 70 ° C |
Ana | X m 150 120 50 mm o |
Weight | 0.2 kg |
ka Emerson KJ3225X1-BA1 12P4174X042 he hana kiʻekiʻe RTD/resistance input card designed for accurate temperature measurement in industrial automation environments. This module is part of the DeltaV moʻo and provides superior precision and reliability for monitoring temperature-sensitive processes. It is equipped with 16 input channels, allowing users to connect multiple RTD sensors and obtain real-time, high-resolution data.
Engineered for compatibility with the DeltaV distributed control system (DCS), this module ensures seamless integration into existing automation infrastructures. Its robust design enables operation in harsh industrial conditions, maintaining high accuracy and stability across a wide range of temperatures.
✔ Pono Kiʻekiʻe & Hoʻoholo – Provides precise and high-resolution temperature measurements for critical process control.
✔ Hoʻohui ʻole ʻia ʻo DeltaV – Designed specifically for compatibility with DeltaV DCS, ensuring easy system configuration and operation.
✔ Multiple RTD Compatibility – Supports a variety of RTD sensor types, offering flexibility in different applications.
✔ Paʻa a Paʻa – Built to withstand industrial environments with a wide operating temperature range and robust design.
✔ Hoʻokomo ʻia ma nā ʻano he nui – With 16 channels, this module efficiently collects data from multiple temperature sensors, reducing hardware requirements.
✔ Kāleʻa Kaʻikaʻi – Operates on low power consumption, making it a cost-effective solution for industrial automation.
Model Number | Description |
---|---|
KJ3222X1-BA1 | Analog Input Card, 16-channel |
KJ3223X1-BA1 | Analog Output Card, 16-channel |
KJ3204X1-BA1 | Digital Input Card, 16-channel |
KJ3205X1-BA1 | Digital Output Card, 16-channel |
KJ3241X1-BA1 | HART Interface Card |
Model Number | Description |
---|---|
KJ2005X1-BA1 | Controller module for DeltaV DCS |
KJ4001X1-BA2 | Module lako mana |
KJ1501X1-BA1 | Module hoʻopili pili |
KJ2101X1-BA1 | Module hoʻoponopono ʻokoʻa |
KJ3224X1-BA1 | Temperature input card |
Q1: What types of RTD sensors are compatible with the KJ3225X1-BA1 module?
A1: This module supports a variety of RTD sensors, including PT100, PT500, and PT1000, among others.
Q2: Is this module compatible with non-Emerson control systems?
A2: Ka KJ3225X1-BA1 is specifically designed for seamless integration with Emerson’s DeltaV DCS. Compatibility with other control systems may require additional interfaces.
Q3: ʻEhia mau ala e kākoʻo ai kēia module?
A3: It supports 16 channels for RTD/resistance input measurement.
Q4: Hiki i kēia module ke hana i nā mahana wela?
A4: Yes, it operates reliably in temperatures ranging from -40°C to 70°C.
Q5: Does this module require external power?
A5: Yes, it operates on a 24V DC power supply.
Q6: How is the data resolution of this module?
A6: It provides high-resolution, 16-bit measurement for precise data collection.
Q7: Is it possible to use this module for hazardous environments?
A7: Yes, it is designed to withstand industrial environments, but users should verify certifications for hazardous locations.
Q8: Does it support remote monitoring?
A8: Yes, when integrated with the DeltaV system, it allows for remote data monitoring and control.
Q9: He aha ke ʻano o ka mālama ʻana i kēia module?
A9: Minimal maintenance is needed, but regular calibration and system checks are recommended for optimal performance.
Q10: How do I install the module in a DeltaV system?
A10: Installation is straightforward—simply slot the module into the designated DeltaV I/O rack and configure it via the system interface.
Hōʻoiaʻiʻo maoli
ʻO nā kikoʻī huahana a pau he huahana maoli a i lawe ʻia mai. Loaʻa iā mākou ka nui kūʻai makahiki o 300 miliona yuan, a hoʻopuka wale mākou i nā huahana kumu a me ka ʻoiaʻiʻo. Hiki i nā mea kūʻai a pau e hui pū me mākou ma ka pūnaewele ke hauʻoli i nā uku haʻahaʻa.
Hale kūʻai manuahi
Loaʻa iā mākou nā hiʻohiʻona huahana holoʻokoʻa, 80% o nā hiʻohiʻona maʻamau i loko o ka waihona, a ua hoʻokumu mākou i nā kahawai ma Asia, ʻApelika, ʻAmelika ʻAmelika, ʻAmelika Hema, a me ʻEulopa, e hoʻopōkole pono i ka manawa hoʻoponopono kauoha a hoʻomāʻona i nā mea kūʻai aku i ka manawa kūpono.
Hui Kūkākūkā
Hoʻouna wikiwiki. Hiki ke hoʻouna ʻia nā huahana Spot i ka lā hoʻokahi, a ʻo ka manawa hoʻouna ʻana he 20% ʻoi aku ka wikiwiki ma mua o nā hoa ma ka awelika, me ka helu pololei o ka manawa hāʻawi o 99%.
Manaʻo ma hope o-kūʻai aku lawelawe
24-hola ma hope o ke kūʻai aku i ka hui hōʻoiaʻiʻo, ʻoihana a me ka ʻōnaehana hoʻokele maʻamau.