ka Bently Nevada 3500 / 60-03-00 133835-01 TC Isolation I/O Module he mea hoohui o ka Bently Nevada 3500 moʻo machinery monitoring system, designed specifically to provide accurate temperature measurements via thermocouple (TC) sensors. The module is built to offer isolation for the input signals, ensuring that the machinery protection system remains unaffected by any electrical noise or interference. The module can be seamlessly integrated into the 3500 moʻo, enhancing the overall monitoring capabilities of critical rotating equipment in industries like power generation, oil and gas, and manufacturing.
ka 3500 / 60-03-00 offers precise, isolated input handling of thermocouple signals, ensuring high reliability and system integrity. This is crucial for industries where temperature management plays a key role in preventing equipment failures and improving system uptime.
ka 3500 / 60-03-00 133835-01 TC Isolation I/O Module is ideal for applications requiring accurate temperature readings from thermocouple sensors in harsh environments. Key applications include:
Ka mana hana: Monitoring the temperature of turbines, boilers, and other critical equipment to ensure optimal performance and prevent overheating.
Oil, a me Ke Kinoea: Providing temperature monitoring in compressors, pumps, and other rotating equipment to safeguard against thermal damage.
Manufacturing: Ensuring that machinery in production lines operates within specified temperature ranges to maintain efficiency and avoid malfunctions.
Nāu hou: Used for monitoring process temperatures in refineries, where thermocouple sensors are widely applied for accurate and continuous temperature measurements.
Hoʻokaʻawale hōʻailona: This module isolates the thermocouple inputs from the main system, effectively protecting sensitive electronics from voltage spikes and interference.
Ke Kula kiʻekiʻe: Ensures highly accurate temperature measurements through thermocouple sensors, providing real-time data for optimal decision-making.
Hoʻohālikelike laulā: It is fully compatible with the Bently Nevada 3500 system, allowing for easy integration and seamless operation within the monitoring infrastructure.
Durability: Designed to withstand harsh industrial environments, ensuring reliable performance in demanding conditions.
Prevention of Equipment Failures: With accurate temperature monitoring, the module helps detect potential issues early, preventing costly damage to critical machinery.
oluolu mea hoʻonoho: Quick and simple to install with minimal downtime, reducing operational disruptions during setup.
Bently Nevada, a subsidiary of Baker Hughes, is renowned for its expertise in machinery condition monitoring and protection systems. The 3500 Series is one of the company’s flagship product lines, trusted by industries worldwide for its reliability and ability to provide early warnings of equipment failure. Bently Nevada’s products are recognized for their durability, advanced monitoring capabilities, and ease of integration into existing infrastructure.
ka 3500 Series is a comprehensive suite of machinery protection and monitoring modules developed by Bently Nevada. The series includes a variety of solutions for monitoring parameters such as vibration, temperature, pressure, speed, and other critical variables in rotating machinery. The 3500 / 60-03-00 module is part of this versatile series, designed specifically for thermocouple input handling with isolation for optimal performance in high-noise environments.
aiao | Value |
---|---|
ʻEnsionslelo (W x H x D) | X m 241.3 24.4 99.1 mm o |
Weight | 0.45 kg |
ʻAno hoʻokomo | Thermocouple (TC) |
Hoʻokaʻawale hōʻailona | ʻAe |
Lako ikehu | 24 VDC (Nā inoa) |
Kākoʻo ʻia nā Kanal | 8 TC Inputs |
ia auoiaea | Integrated with 3500 Series System |
pae'ōnaehana Mahana | -40 ° C a 85 ° C |
Certifications | CE, UL, CSA, ATEX (depending on model) |
kükohu | Description | hoakaka |
---|---|---|
3500 / 60-02-00 | TC Isolation I/O Module | 241.3 x 24.4 x 99.1 mm, 0.45 kg |
3500 / 60-01-00 | RTD Isolation I/O Module | 241.3 x 24.4 x 99.1 mm, 0.45 kg |
3500 / 60-03-01 | Thermocouple Isolation I/O Module | 241.3 x 24.4 x 99.1 mm, 0.45 kg |
3500 / 60-01-01 | RTD/TC Isolation I/O Module | 241.3 x 24.4 x 99.1 mm, 0.45 kg |
3500 / 42-01-00 | Analog Input Isolation Module | 241.3 x 24.4 x 99.1 mm, 0.45 kg |
kükohu | Description | hoakaka |
---|---|---|
3500 / 20-01-00 | Module kiaʻi haʻalulu | 241.3 x 24.4 x 241.8 mm, 0.91 kg |
3500 / 72-01-00 | Shaft Speed Monitoring Module | 241.3 x 24.4 x 241.8 mm, 0.91 kg |
3500 / 44-01-00 | Mana Pāna hana | 241.3 x 24.4 x 241.8 mm, 0.91 kg |
3500 / 53-01-00 | Pressure/Temperature Monitoring Module | 241.3 x 24.4 x 241.8 mm, 0.91 kg |
3500 / 72-02-00 | Speed Sensor Interface Module | 241.3 x 24.4 x 241.8 mm, 0.91 kg |
Q1: He aha ka hana o ka 3500 / 60-03-00 module?
A1: ka 3500 / 60-03-00 he TC Isolation I/O Module designed to handle thermocouple signals with isolation, ensuring precise temperature measurements and protecting the system from electrical noise.
Q2: How many thermocouple channels does the module support?
A2: The module supports up to 8 thermocouple inputs.
Q3: He aha ka mana e pono ai no ka module?
A3: The module requires a 24 VDC nominal power supply.
Q4: What temperature range is the module capable of operating in?
A4: Hoʻohana ka module i nā mahana mai -40°C a 85°C.
Q5: He kūpono anei ka module no nā wahi pōʻino?
A5: Yes, it is certified with CE, UL, CSA, and ATEX for use in hazardous environments, depending on the specific model.
Q6: What type of signals does this module handle?
A6: The module handles thermocouple (TC) signals.
Q7: He aha ke kaumaha o ka module?
A7: ʻO ke kaumaha o ka module he 0.45 kg.
Q8: What is the primary benefit of the isolation feature?
A8: The isolation feature protects the system from voltage spikes and electrical noise, ensuring that the measurements are not affected by external interference.
Q9: Can the module be integrated with other Bently Nevada ʻōnaehana?
A9: ʻAe, ua hui pū me ka Bently Nevada 3500 moʻo ʻōnaehana nānā mīkini.
Q10: What industries are best suited for this module?
A10: The module is ideal for industries like power generation, oil and gas, and manufacturing, where temperature monitoring of critical equipment is essential.
Hōʻoiaʻiʻo maoli
ʻO nā kikoʻī huahana a pau he huahana maoli a i lawe ʻia mai. Loaʻa iā mākou ka nui kūʻai makahiki o 300 miliona yuan, a hoʻopuka wale mākou i nā huahana kumu a me ka ʻoiaʻiʻo. Hiki i nā mea kūʻai a pau e hui pū me mākou ma ka pūnaewele ke hauʻoli i nā uku haʻahaʻa.
Hale kūʻai manuahi
Loaʻa iā mākou nā hiʻohiʻona huahana holoʻokoʻa, 80% o nā hiʻohiʻona maʻamau i loko o ka waihona, a ua hoʻokumu mākou i nā kahawai ma Asia, ʻApelika, ʻAmelika ʻAmelika, ʻAmelika Hema, a me ʻEulopa, e hoʻopōkole pono i ka manawa hoʻoponopono kauoha a hoʻomāʻona i nā mea kūʻai aku i ka manawa kūpono.
Hui Kūkākūkā
Hoʻouna wikiwiki. Hiki ke hoʻouna ʻia nā huahana Spot i ka lā hoʻokahi, a ʻo ka manawa hoʻouna ʻana he 20% ʻoi aku ka wikiwiki ma mua o nā hoa ma ka awelika, me ka helu pololei o ka manawa hāʻawi o 99%.
Manaʻo ma hope o-kūʻai aku lawelawe
24-hola ma hope o ke kūʻai aku i ka hui hōʻoiaʻiʻo, ʻoihana a me ka ʻōnaehana hoʻokele maʻamau.