Product Name: FSC 10024/H/I
Brand: Honeywell
Series / Family: FSC (Fail‑Safe / Safety Control / Communication Modules)
The FSC 10024/H/I is a communication / interface module within the FSC family, intended to provide data link connectivity between the FSC safety / control system and external devices or subsystems.
Its primary role is to handle multiple communication protocols (e.g. RS‑232, RS‑422, RS‑485), support configurable baud rates, and bridge internal backplane communications with external network / bus devices. It is designed for industrial environments and plays a critical role in enabling integrated automation and safety systems to exchange data reliably.
Because it lies at the boundary between safety logic and external networks, the 10024/H/I module must provide robust diagnostics, data integrity checks, and fault tolerance as part of an overall fail-safe architecture.
| Parameter | Value / Description |
|---|---|
| Model | FSC 10024/H/I |
| Module Type | Communication / Interface Module |
| Supported Protocols | RS‑232, RS‑422, RS‑485 |
| Baud Rate / Data Rate | Up to 19,200 bps (some sources) |
| Power Supply Voltage | 5 VDC via system backplane |
| Current Consumption | ~650 mA (typical) |
| Dimensions (L × W × H) | 15.2 cm × 20.3 cm × 5.1 cm (i.e. 152 mm × 203 mm × 51 mm) |
| Weight | ~0.3 kg |
| Operating Temperature Range | –40 °C to +85 °C |
| Mounting | Rack / slot mountable in FSC enclosure |
| Diagnostic Capabilities | Error detection, status LEDs, configurable fallback modes |
| Node / Channel Support | Up to 8 communication channels (depending on configuration) |
| Default Mode / State Memory | Retains last state / configuration |
Notes / caveats:
Some listings report the dimension as “6.0″ x 8.0″ x 2.0″” which corresponds to ~15.2 cm × 20.3 cm × 5.1 cm, matching the above.
The ~0.3 kg weight is consistent across multiple sources for this module.
The power consumption and current figures (650 mA at 5VDC) are approximate and may vary based on active channels, termination loads, or internal hardware.
Environmental limits (humidity, shock, vibration) are typical industrial ranges but not always publicly documented.
The FSC 10024/H/I is typically used in:
Safety Instrumented Systems (SIS) or control systems requiring external communication links
Connecting FSC control racks / safety systems to external devices (e.g. remote I/O, field instrument networks, HMIs, SCADA systems)
Integrating RS‑232 / RS‑422 / RS‑485 device networks into a safety control architecture
Systems where diagnostic feedback from field devices must be fed into the safety logic
Bridging internal modules to broader automation communications protocols
Essentially, any scenario where your safety or controller core must communicate with external instrumentation or networks benefits from this module.
Multiprotocol support: RS‑232, RS‑422, RS‑485 on a single module makes it versatile for many field devices.
Robustness in extreme temperature: –40 °C to +85 °C rating suits harsh environments.
Compact weight and form factor: At ~0.3 kg and modest packaging, it fits well in modular racks.
Diagnostic capabilities: Provides status LED and fallback to last state to maintain stability during faults.
Seamless integration into FSC ecosystem: Designed to operate with the internal backplane and coordinate with other FSC modules.
Configurable communication channels: Ability to handle multiple external nodes / devices improves flexibility.
Data integrity & fault detection: Ensures reliable data exchange with built‑in error checks and fallback mechanisms.
State retention: Maintains last-mode configuration to preserve continuity after transient faults.
| Model | Description / Role | Key Variation or Feature |
|---|---|---|
| FSC 10024/H/I | Communication / interface module (subject) | Multi-protocol interface to external networks |
| FSC 10024/I/F | Enhanced communication interface variant | Alternate variant with protocol or feature changes |
| FSC 10024/H/F | Enhanced communication module | Possibly higher performance or extended features |
| FSC 10024/F/F | Communication module (other variant) | Varying internal hardware or diagnostics |
| FSC 10024/H/Other | Alternate variant in FSC 10024 family | Slightly different protocol or mounting or capacity |
These variants reflect different protocol support, speed, or hardware capabilities within the same module family.
| Model | Function / Domain | Use / Significance |
|---|---|---|
| FS‑BSDOL‑04UNI | Range‑setting module for output diagnostics | Calibrates output thresholds in safety loops |
| SDOL‑0424 | Digital output monitoring module | Works along with range‑setting modules |
| FS‑TSDO‑04UNI | Safety digital output module | Provides fail-safe outputs under control logic |
| FS24X | Multi‑spectrum flame detector | Fire / flame detection in hazardous sites |
| FS10‑R | Flame detector / controller module | Rapid flame sensing and control |
Q1: What is the primary use of FSC 10024/H/I?
A1: It serves as a communication interface module in the FSC system, enabling RS‑232/422/485 connectivity between the safety/control core and external devices.
Q2: How many external communication channels does it support?
A2: Up to eight channels, though actual supported count depends on configuration and hardware variant.
Q3: What power supply does it require?
A3: It operates at 5 VDC, usually supplied via the system backplane.
Q4: What is its approximate weight and size?
A4: It weighs about 0.3 kg and measures ~152 × 203 × 51 mm (L × W × H).
Q5: Can it operate in very cold or hot environments?
A5: Yes. Its operating temperature range is –40 °C to +85 °C, making it suitable for harsh industrial settings.
Q6: Does it preserve its configuration after power loss?
A6: Yes, it retains its last state or configured parameters to allow recovery after transient faults.
Q7: What diagnostics does it offer?
A7: It provides status LEDs, error checking, fallback to last known state, and internal error detection.
Q8: If a communication channel fails, what happens?
A8: The module’s diagnostics detect the failure and isolate it without crashing the entire module—other channels remain operative.
Q9: Can I hot-swap this module?
A9: No. To ensure system safety, the module should only be swapped when the system is in a safe, powered-down state or maintenance mode.
Q10: Which variant should I choose: H/I, I/F, or H/F?
A10: Choose based on your required protocol support, speed, hardware robustness, or diagnostic features. The H/I variant is balanced for general use; other variants may offer enhanced features or different protocol support.
Authenticity guarantee
All product specifications are original and authentic imported products. We have an annual sales volume of 300 million yuan, and we only produce original and authentic products. All customers who cooperate with us directly online can enjoy low discounts.
Free warehouse
We have a complete range of product models, 80% of conventional models are in stock, and we have established channels in Asia, Africa, North America, South America, and Europe, effectively shortening the order processing time and satisfying customers in a timely manner.
Technical Team
Fast delivery. Spot goods can be shipped on the same day, and the delivery time transaction is 20% faster than that of peers on average, with a delivery time accuracy rate of 99%.
Thoughtful after-sales service
24-hour after-sales service guarantee team, professional and standardized management service system.