The Bently Nevada 3500/92 133323-01 is a communication gateway module designed to bridge the 3500 Machinery Protection System with external systems such as DCS, SCADA, or PLC-based platforms. It provides robust communication capabilities via Modbus RS-485 and serial interfaces, making it essential for plants that require secure, accurate, and real-time machinery data integration.
Its primary role is to transmit monitored parameters — such as vibration levels, temperature, speed, alarms, and equipment statuses — from the 3500 rack to supervisory control systems. This enables centralized monitoring and rapid diagnostics, reducing unplanned downtime.
| Parameter | Specification |
|---|---|
| Model | 133323-01 |
| Series | 3500 Machinery Protection System |
| Brand | Bently Nevada |
| Function | Modbus RS-485 Communication Gateway Module |
| Communication Protocols | Modbus RTU (RS-485), RS-232, RS-422 |
| Supported Baud Rates | 9600, 19200, 38400, 57600, 115200, 230400 |
| Data Format | Configurable Modbus Register Utility |
| Ethernet Support | No (Modbus RTU Only) |
| Max Communication Distance | Up to 1200 meters via RS-485 |
| Max Slaves Supported | 32 Modbus Slave Devices |
| Modbus Registers | 256 Registers |
| I/O Channels | 64 Input/Output Points |
| Input Voltage | 24 VDC |
| Power Consumption | Approx. 7.7 W |
| Operating Temperature | -30°C to +65°C |
| Storage Temperature | -40°C to +85°C |
| Humidity | 0–95% RH (non-condensing) |
| Mounting | Rear slot of 3500 rack (full-height module) |
| Dimensions (H × W × D) | 241 mm × 24.4 mm × 99.1 mm |
| Weight | 0.44 kg |
| LED Indicators | OK, TX, RX LEDs for status and diagnostics |
Plant Automation: Enables seamless data exchange between the machinery protection system and automation platforms.
Predictive Maintenance: Helps identify early signs of equipment degradation by sharing real-time condition data.
Legacy System Integration: Useful for plants looking to extend the life of older equipment through modern monitoring.
Vibration and Temperature Monitoring Systems: Essential in applications involving turbines, compressors, fans, pumps, and motors.
Centralized Diagnostics: Allows condition monitoring teams to view multiple machines from a single control center.
Reliable Communication: Supports long-distance RS-485 communication up to 1.2 kilometers, ideal for large industrial sites.
Flexible Configuration: Custom Modbus register mapping allows users to export exactly the data needed.
Easy Integration: Designed for compatibility with most industrial automation and SCADA systems.
Rugged Design: Withstands wide temperature ranges and harsh environmental conditions.
Rack Compatibility: Installs directly into the 3500 rack, occupying only one rear slot.
Diagnostic LEDs: Built-in status LEDs simplify troubleshooting and ensure system visibility.
Series: 3500 Machinery Protection System
Brand: Bently Nevada
Module Type: Communication Gateway I/O Module
| Model | Function | Dimensions (mm) | Weight (kg) | Key Features |
|---|---|---|---|---|
| 3500/92 125736-01 | Ethernet + Serial Gateway Module | 241 × 24.4 × 99.1 | 0.44 | Supports both Modbus TCP/IP and serial communication |
| 3500/90-01-00-00 | Legacy Modbus Gateway Module | Standard rack size | 0.45 | Earlier version with fixed Modbus registers |
| 3500/92 136180-01 | Advanced Gateway with Alarm Integration | 241 × 24.4 × 99.1 | 0.45 | Advanced Modbus mapping and signal handling |
| 3500/53 133388-01 | Display/Output Communication Module | Standard module size | 0.50 | Interfaces with local displays and external relays |
| 3500/22M 138607-01 | Transient Data Interface Module | Standard module size | 0.50 | Captures high-speed vibration and fault data |
| Model | Function | Dimensions (mm) | Weight (kg) | Key Features |
|---|---|---|---|---|
| 3500/40M | Proximitor Monitor | Standard 3500 size | 0.50 | Monitors shaft vibration and displacement |
| 3500/42M | Vibration/Position Monitor | Standard 3500 size | 0.55 | Monitors radial and axial position |
| 3500/50 | Tachometer / Keyphasor Module | Standard 3500 size | 0.45 | Provides speed and phase reference |
| 3500/15 | Power Supply Module | Rack-mounted | 0.45 | Powers entire 3500 system |
| 330104-00-05-10-02-00 | Proximity Probe | Probe body + cable | 0.10 | High-accuracy shaft displacement measurement |
Q1: What is the primary function of the 133323-01 module?
A1: It acts as a communication gateway, enabling the 3500 rack to send data such as sensor values and alarms to external systems via Modbus RTU over RS-485.
Q2: Can this module connect to Ethernet networks?
A2: No, this model only supports serial communication (RS-485, RS-232, RS-422). For Ethernet, other models like 125736-01 are recommended.
Q3: What’s the maximum cable length supported over RS-485?
A3: It supports cable lengths up to 1,200 meters for RS-485, making it suitable for wide-area industrial installations.
Q4: How is the Modbus register mapping configured?
A4: It uses a configurable register utility, allowing users to select and map desired data points to Modbus registers.
Q5: How many devices can be connected as Modbus slaves?
A5: The module can communicate with up to 32 Modbus slave devices.
Q6: Is the 133323-01 module hot-swappable?
A6: No, it is not hot-swappable. The rack must be powered down during installation or replacement.
Q7: What are the environmental tolerances?
A7: It operates between -30°C and +65°C, and is rated for 0–95% relative humidity, non-condensing.
Q8: How much space does the module take in the rack?
A8: It occupies one full-height rear slot in the 3500 rack.
Q9: Does the module provide any visual feedback?
A9: Yes, it features LED indicators (OK, TX, RX) to show operational status and communication activity.
Q10: What systems can this module integrate with?
A10: It can integrate with any system that supports Modbus RTU, including DCS, PLCs, and SCADA systems.
Authenticity guarantee
All product specifications are original and authentic imported products. We have an annual sales volume of 300 million yuan, and we only produce original and authentic products. All customers who cooperate with us directly online can enjoy low discounts.
Free warehouse
We have a complete range of product models, 80% of conventional models are in stock, and we have established channels in Asia, Africa, North America, South America, and Europe, effectively shortening the order processing time and satisfying customers in a timely manner.
Technical Team
Fast delivery. Spot goods can be shipped on the same day, and the delivery time transaction is 20% faster than that of peers on average, with a delivery time accuracy rate of 99%.
Thoughtful after-sales service
24-hour after-sales service guarantee team, professional and standardized management service system.