Honeywell FC‑IO‑0002 Product Introduction The Honeywell FC‑IO‑0002 is a robust I/O Extender Module tailored for Honeywell’s Safety Manager A.R.T. systems. It occupies key chassis slots (typically 20 and……
Honeywell FC-IO-0002 I/O Extender Module
  • Honeywell
  • FC-IO-0002
  • I/O Extender Module
  • USA
  • 132.5 x 81 x 180 mm
  • 0.3kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 96

Our advantage

Honeywell FC-IO-0002 I/O Extender Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Honeywell FC-IO-0002 I/O Extender Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Honeywell FC-IO-0002 I/O Extender Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Honeywell FC-IO-0002 I/O Extender Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Honeywell FC‑IO‑0002

Product Introduction

The Honeywell FC‑IO‑0002 is a robust I/O Extender Module tailored for Honeywell’s Safety Manager A.R.T. systems. It occupies key chassis slots (typically 20 and 21), providing foundational support for communication relay, watchdog signal distribution, 5 V power routing, and operational status indication across I/O modules.


Technical Specifications

Parameter Specification
Model FC‑IO‑0002
Brand Honeywell
Function I/O Extender for Safety Manager A.R.T. chassis
Communication Transfer Bridges control processor to I/O modules
Watchdog Distribution Routes watchdog pulses and isolates failing slots
5 V Distribution Supplies 5 V to two module groups in chassis
Status Indication LED status (Off / Green / Red)
Slots Used Slot 20 (primary) with Slot 21 as standby
Power Input Dual 5 V DC inputs via OR-ing, up to 100 mA
Power Output Groups Two groups, each delivering >1.25 A with 0.2–0.8 V drop
Dimensions 4 TE (HP) width, 3 HE (height) rack module
Weight ≈ 300 g
Operating Temps –40 °C to +70 °C (typical range)
Certifications CE, TÜV, UL, CSA compliant
Series Safety Manager I/O Support Modules

Applications

This extender module enables critical system functions such as:

  • Stable data transfer from control processors to I/O modules

  • Watchdog signal management to detect and isolate failing modules

  • Distributing clean 5 V power across module slots

  • Providing visual status feedback via LEDs

  • Supporting redundancy for high-availability safety systems


Advantages

  • Critical redundancy support: Automatic failover between primary and standby module slots

  • Power and signal goodness: Ensures uniform power and communication delivery

  • Fault isolation: Quickly disables troubled I/O via watchdog control

  • Clear diagnostics: LED indicators offer instant health status view

  • Compact, modular design: Efficiently fits standard I/O racks with minimal footprint

  • Certified for safety systems: Meets major industrial standards


Related Models (Same or Relevant Series)

Model Description
FC‑IO‑0002 I/O Extender module (this unit)
FC‑USI‑0002 Universal Safety Interface Module
FC‑IOCHAS‑0002R Redundant I/O Chassis housing multiple modules
FC‑TERM‑0002 Bus terminator for redundant I/O communications
FC‑IOCHAS‑0002S Standard I/O chassis (single config)

Popular Honeywell Modules (Same Brand)

Model Description
FC‑IO‑0002 I/O extender (this model)
FC‑USI‑0002 Universal Safety Interface
FC‑DCOM‑234/485 Serial communication adapter
FC‑FANWR‑24R Cabinet cooling fan module
FC‑IODI16 16-point digital input expansion


Frequently Asked Questions (QA Format)

Q1: What is the role of FC‑IO‑0002 in the system?
A1: It extends control functions—communication, power, watchdog—to I/O modules.


Q2: How is redundancy achieved?
A2: Installed in primary and standby slots; standby module takes over if primary fails.


Q3: What voltage does it distribute?
A3: Supplies 5 V to two distinct groups of I/O positions, each capable of >1.25 A.


Q4: What does the status LED indicate?
A4: Off means no power, green means healthy operation, red indicates fault.


Q5: Can it isolate faulty modules?
A5: Yes, through watchdog signal control it can disable failing I/O slots.


Q6: What are the module’s power input specs?
A6: Dual 5 V DC inputs via OR-ing circuits, supporting up to about 100 mA.


Q7: What are its physical dimensions?
A7: Occupies 4 TE (HP) width and 3 HE height in a rack enclosure.


Q8: How much does one weigh?
A8: Approximately 300 g.


Q9: What temperature range can it operate in?
A9: Typically –40 °C to +70 °C.


Q10: Is it safety-certified?
A10: Yes, holds CE, TÜV, UL, and CSA approvals.