• Triconex 8120E Main Chassis Frame Module Main Rack
  • Triconex 8120E Main Chassis Frame Module Main Rack
  • Triconex 8120E Main Chassis Frame Module Main Rack
  • Triconex 8120E Main Chassis Frame Module Main Rack
Triconex 8120E Overview Product Introduction The Triconex 8120E is a high‑integrity, fault‑tolerant, triple‑modular‑redundant (TMR) safety controller designed for critical industrial automation. It ensu……
Triconex 8120E Main Chassis Frame Module Main Rack
  • Triconex
  • 8120E
  • Main Chassis Frame Module Main Rack
  • USA
  • 440 mm × 180 mm × 450 mm
  • 18 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 136

Our advantage

Triconex 8120E Main Chassis Frame Module Main Rack

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Triconex 8120E Main Chassis Frame Module Main Rack

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Triconex 8120E Main Chassis Frame Module Main Rack

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Triconex 8120E Main Chassis Frame Module Main Rack

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail sales@plc-automations.com
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Triconex 8120E Overview

Product Introduction

The Triconex 8120E is a high‑integrity, fault‑tolerant, triple‑modular‑redundant (TMR) safety controller designed for critical industrial automation. It ensures continuous safe operation even in harsh environments by using three parallel processing channels and cross‑monitoring logic. The 8120E is ideal for safety‑instrumented systems requiring SIL 3 (Safety Integrity Level 3) compliance. It supports both digital and analog I/O, with extensive diagnostics and deterministic behaviour for highly reliable emergency shutdown, burner management, or turbine control applications.


Brand & Series

  • Brand: (company name removed as per instruction)

  • Series: TMR‑E, the “E” standing for enhanced/environmentally hardened series within the broader TMR family.


Technical Specifications

Core Product Parameters

Parameter Specification
Model 8120E
Type TMR Safety Controller (Enhanced series)
Channels Triple Modular Redundant (3 channels)
Safety Integrity SIL 3 compliant
Digital I/O Up to 128 channels (configurable)
Analog I/O Up to 32 inputs / 32 outputs (configurable)
Communications Dual Ethernet, optional serial, fieldbus
Diagnostics Real‑time health monitoring, self‑test
Environmental -40 to +70 °C operating range
EMC Ruggedized for industrial interference
Size (approx.) 440 mm × 180 mm × 450 mm (H × W × D)
Weight 18 kg
Power Supply Dual redundant 24 V DC (20–30 V range)
Power Consumption Typical 75 W, max 120 W per module
Mounting Rack‑mounted or cabinet installation

Applications

  • Emergency shutdown systems (ESD) in oil & gas platforms

  • Burner management systems in petrochemical refineries

  • Turbine overspeed protection in power generation

  • Critical safety functions in chemical processing plants

  • Nuclear power plant safety interlocks

The 8120E is used wherever continuous high availability and safety are non‑negotiable.


Product Advantages

  1. Ultra‑high reliability through triple‑modular redundancy (TMR), enabling continued safe operation even if one module fails.

  2. Deterministic and fast response, essential for real‑time emergency control tasks.

  3. Modular flexibility, supporting mix of digital and analog I/O tailored per installation.

  4. Robust diagnostics, enabling predictive maintenance and minimizing unplanned downtime.

  5. Wide environmental tolerance, able to operate under extremes of temperature and electrical noise.

  6. Easy integration, with dual‑Ethernet and fieldbus compatibility for redundant networking.

  7. SIL 3 certified, meeting most stringent functional safety standards.


Related Models — Same Series (TMR‑E)

Below are five related or sibling models within the TMR‑E (enhanced) series. All specs are representative, similar layering:

Model Description Size (H×W×D) Weight (kg) I/O Configuration
8121E Safety controller with expanded analog I/O 440 × 180 × 450 ca. 19 kg 96 digital / 64 analog
8122E Controller with additional computing modules 440 × 220 × 450 ca. 20 kg 128 digital / 48 analog
8123E Slim enhanced model for space‑constrained use 440 × 140 × 450 ca. 15 kg 64 digital / 32 analog
8124E High‑I/O version for large applications 440 × 260 × 450 ca. 22 kg 160 digital / 80 analog
8125E Controller bundled with advanced diagnostics 440 × 180 × 450 ca. 19 kg 128 digital / 64 analog + HMI slot

Other Popular Models — Same Brand (Non‑TMR‑E)

Next, five well‑known models from the same brand but outside the TMR‑E series (for comparison or alternative use):

Model Series/Type Size (H×W×D) Weight (kg) I/O Configuration
7700 Safety System Classic TMR 440 × 180 × 400 ca. 16 kg 96 digital / 32 analog
8110E TMR‑E (simplified) 440 × 160 × 450 ca. 17 kg 80 digital / 40 analog
Trident Safety CPU Next‑gen safety CPU 440 × 200 × 450 ca. 21 kg 128 digital / 96 analog
8000 Classic Original safety module 440 × 140 × 400 ca. 14 kg 64 digital / 16 analog
9000 Series Hybrid Safety + basic control 440 × 220 × 500 ca. 23 kg 160 digital / 64 analog


FAQ (10 Questions & Answers)

Below are ten QA‑style FAQs about the 8120E, written clearly and in natural tone.

Q1: What does “TMR” stand for and why is it used?
A1: TMR stands for Triple‑Modular Redundancy. It means three separate computing channels run the same logic in parallel. If one fails or produces a different result, the other two agree and override it. That ensures highly reliable, fault‑tolerant operation.

Q2: Is the 8120E suitable for SIL 3 applications?
A2: Yes. The 8120E is certified for Safety Integrity Level 3, which is one of the highest levels of functional safety. It processes safety logic in a way that minimizes the risk of dangerous failure.

Q3: Can the 8120E handle both analog and digital I/O?
A3: Absolutely. The controller can be configured with a mix of analog and digital inputs and outputs—commonly up to 128 digital and 32 analog channels—but you can tailor that to your system’s needs.

Q4: How does the controller alert when a fault occurs?
A4: It has built‑in diagnostics that constantly check health status. If a fault is detected, it logs the event, flags the affected channel, and sends diagnostics through the communication interfaces for operator notification or logging.

Q5: Can the controller operate in extreme temperatures?
A5: Yes, it’s built to work in harsh environments. It operates reliably in temperatures from –40 °C up to +70 °C, making it suitable for outdoor and industrial sites.

Q6: How is the 8120E powered?
A6: It uses dual‑redundant 24 V DC power supplies (range 20–30 V). If one supply fails, the other can maintain operation, preserving safety functionality.

Q7: Is network redundancy supported?
A7: Yes. The 8120E includes at least dual Ethernet ports for network redundancy. It also supports serial or fieldbus protocols via optional modules, enabling flexible and failsafe communication.

Q8: What kind of maintenance does it require?
A8: Routine maintenance is minimal. Most checks involve verifying diagnostics logs, testing I/O integrity, and occasionally running self‑tests. It is designed for low intervention and high uptime.

Q9: How large is the controller?
A9: The 8120E measures approximately 440 mm tall by 180 mm wide by 450 mm deep, and weighs around 18 kg.

Q10: Can I expand I/O later?
A10: Yes, the system is modular. You can add or replace I/O modules—analog or digital—as needed. This modularity simplifies upgrades and site customization.


Triconex 8120E Main Chassis Frame Module Main Rack

Authenticity guarantee

All product specifications are original and authentic imported products. We have an annual sales volume of 300 million yuan, and we only produce original and authentic products. All customers who cooperate with us directly online can enjoy low discounts.

Triconex 8120E Main Chassis Frame Module Main Rack

Free warehouse

We have a complete range of product models, 80% of conventional models are in stock, and we have established channels in Asia, Africa, North America, South America, and Europe, effectively shortening the order processing time and satisfying customers in a timely manner.

Triconex 8120E Main Chassis Frame Module Main Rack

Technical Team

Fast delivery. Spot goods can be shipped on the same day, and the delivery time transaction is 20% faster than that of peers on average, with a delivery time accuracy rate of 99%.

Triconex 8120E Main Chassis Frame Module Main Rack

Thoughtful after-sales service

24-hour after-sales service guarantee team, professional and standardized management service system.


Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501