• Epro PR9670/001-000 Eddy Current Sensor
  • Epro PR9670/001-000 Eddy Current Sensor
  • Epro PR9670/001-000 Eddy Current Sensor
  • Epro PR9670/001-000 Eddy Current Sensor
Product Overview The Epro PR9670/001-000 is associated with Epro’s PR9670 series of connection cables used in industrial machinery monitoring installations. It is intended for signal connection be……
Epro PR9670/001-000 Eddy Current Sensor
  • Epro
  • PR9670/001-000
  • Eddy Current Sensor
  • Germany
  • Optional
  • 3 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 8

Our advantage

Epro PR9670/001-000 Eddy Current Sensor

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Epro PR9670/001-000 Eddy Current Sensor

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Epro PR9670/001-000 Eddy Current Sensor

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Epro PR9670/001-000 Eddy Current Sensor

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Epro PR9670/001-000 is associated with Epro’s PR9670 series of connection cables used in industrial machinery monitoring installations. It is intended for signal connection between a compatible sensor and its monitoring or signal-conditioning equipment.

An important distinction should be made when identifying this part: the PR9670/001-000 designation is documented in an Emerson ordering reference as a 10-meter, two-core shielded connection cable with an open cable end. It is not, by itself, sufficient to identify a complete eddy current probe or establish the probe’s sensing range, sensitivity, or head diameter.

In an industrial eddy current measurement system, the sensor probe detects the position or movement of a conductive target without physical contact. The connecting cable carries the sensor signal to compatible signal-conditioning or monitoring equipment. The quality and correct configuration of this connection are important for maintaining signal integrity in machinery monitoring applications.

The PR9670/001-000 cable configuration is listed with shielding on the electronics side, without protective hose, and with an open cable end. These characteristics should be checked against the existing installation before ordering, particularly where cable routing, connector type, shielding arrangement, or hazardous-area requirements are involved.

For procurement purposes, the supplied listing information identifies the product as an Epro Eddy Current Sensor, with an optional sensor-head diameter and a shipping weight of 3 kg. Because the manufacturer ordering information identifies this particular code as a cable configuration, buyers should confirm whether the offered item is the cable alone or a complete sensor assembly.

Technical Specifications

Parameter Specification
Brand Epro
Manufacturer Emerson / Epro
Model PR9670/001-000
Product Family PR9670 Series
Product Type Eddy Current Sensor System Connection Cable
Cable Length 10 m
Core Configuration Two-core
Shielding Electronics-side shielding
Protective Hose Not included in the documented cable configuration
Cable Termination Open cable end
Application Sensor signal connection in machinery monitoring systems
Sensor Head Diameter Optional, according to supplied listing; confirm the separate probe configuration
Shipping Weight 3 kg
Product Configuration Verify whether cable only or complete sensor assembly is being supplied

The 10 m cable length and cable configuration are based on the manufacturer’s ordering reference. The 3 kg shipping weight and optional sensor-head diameter are supplied listing details, not confirmed physical specifications of the cable alone.

Function and Working Principle

The PR9670/001-000 cable is part of the signal connection arrangement used in machinery monitoring systems. Its role should be understood in the context of the complete sensor installation.

1. Signal Connection

A sensor system requires a reliable electrical connection between its sensing element and the associated signal-conditioning equipment. The cable provides this connection and carries the measurement signal through the installed wiring route.

The cable configuration must match the sensor and monitoring equipment. An incorrect cable type, length, or termination may prevent proper signal transmission.

2. Shielding and Electrical Interference

Industrial environments often contain motors, drives, contactors, transformers, and other equipment that can generate electrical interference.

Shielding helps reduce the influence of unwanted electrical noise on sensitive measurement signals. The PR9670/001-000 configuration is documented with electronics-side shielding.

Shield termination and grounding should follow the applicable installation instructions. Incorrect shield connections can reduce interference protection or introduce unwanted ground-current paths.

3. Open-End Termination

The documented cable configuration has an open cable end rather than a factory-installed connector at that end. This allows connection to the designated terminal or interface arrangement when the installation is designed for that termination.

The installer must verify conductor identification, terminal assignments, shielding treatment, and connection requirements before wiring.

4. Connection to Monitoring Equipment

The cable connects the sensor-side installation to compatible monitoring or signal-conditioning equipment. The exact equipment depends on the sensor type and system architecture.

A cable should not be assumed compatible with every Epro sensor merely because it belongs to the PR9670 family. Confirm the complete sensor model and connection requirements before replacement.

Role in Industrial Machinery Monitoring Systems

The PR9670/001-000 can form part of a machinery monitoring installation where sensor signals are transferred to monitoring equipment for evaluation.

Sensor Signal Transmission

In a typical installation, the sensing element is mounted near a conductive machine target, such as a rotating shaft. The sensor produces a signal related to the target’s position or movement, and the associated cable carries that signal to compatible electronics.

The cable itself does not perform the measurement. Measurement characteristics are determined by the selected sensor, target material, sensor gap, signal conditioner, and system configuration.

Integration with Signal Conditioning Equipment

Eddy current measurement systems generally require compatible electronics to power or condition the probe signal and provide a usable output for monitoring equipment.

The cable must match the sensor and signal-conditioning arrangement. Check the connection diagram and approved cable configuration before connecting it to an existing monitoring rack.

Machinery Protection and Condition Monitoring

Once the sensor signal reaches the monitoring equipment, the system can evaluate machine conditions such as shaft movement, displacement, or vibration, depending on the sensor type and configuration.

Monitoring systems may use configured alarm and trip thresholds to alert operators when measured values exceed established limits. These functions depend on the complete monitoring system, not on the cable alone.

Industrial Applications

The PR9670/001-000 cable configuration may be used in suitable Epro sensor installations for industrial machinery monitoring.

1. Steam and Gas Turbines

Turbine monitoring systems use displacement and vibration measurements to evaluate rotating machinery condition. Sensor cables provide the electrical connection between installed probes and monitoring equipment.

Cable routing must account for machinery temperature, vibration, maintenance access, and the installation’s electrical requirements.

2. Industrial Compressors

Large compressors may use non-contact probes to monitor shaft movement and other mechanical conditions. A correctly specified connection cable helps maintain the signal path between the sensor and the monitoring electronics.

3. Pumps and Motor Assemblies

Industrial pumps and motor-driven systems may incorporate shaft monitoring where mechanical reliability is important. The cable can be part of the associated sensor installation.

4. Generators

Generator monitoring systems may use sensor measurements to evaluate shaft movement and machine vibration. Correct cable configuration and shielding are important for maintaining reliable signal transmission.

5. Petrochemical and Refining Facilities

Continuous machinery monitoring is important in many process plants. Sensor connection cables are installed as part of the instrumentation infrastructure, where cable protection, routing, grounding, and hazardous-area requirements must be considered.

6. General Rotating Machinery

The cable may also be used in suitable monitoring installations for industrial drives, turbines, compressors, and other rotating equipment. Its suitability depends on the connected sensor and the electrical requirements of the complete system.

Installation and System Integration

Correct cable installation is essential for signal integrity and long-term reliability.

1. Verify the Complete Part Number

Before installation, compare the cable label and part number with the existing equipment documentation. Confirm that PR9670/001-000 is the required cable configuration.

Do not substitute a different PR9670 cable solely because the part numbers appear similar. Cable length, shielding side, protective hose, termination, and environmental designation can differ.

2. Confirm Cable Length and Routing

The documented PR9670/001-000 configuration has a nominal length of 10 m. Check the distance between the sensor and the monitoring equipment before installation.

Avoid excessive cable tension, sharp bends, crushing, and routing near sources of strong electrical interference unless the installation instructions permit it.

3. Inspect the Cable Before Installation

Check the cable jacket, conductors, and termination for visible damage. Do not install a cable with cuts, crushed sections, exposed conductors, or damaged shielding.

For replacement work, compare the existing cable’s physical configuration and connection arrangement with the replacement before removing the original.

4. Follow Shielding and Grounding Requirements

The documented cable has electronics-side shielding. Follow the manufacturer’s connection instructions for shield termination and grounding.

Do not assume that both ends should be grounded or that the shield should be connected to an arbitrary cabinet terminal. The correct arrangement depends on the complete measurement system.

5. Verify Terminal Connections

Because the documented cable has an open cable end, installers must identify the conductors and connect them to the correct terminals.

Follow the wiring diagram for the specific sensor and signal-conditioning equipment. Incorrect wiring may result in unstable measurements, signal loss, or damage to connected electronics.

6. Perform a Functional Check

After installation, inspect the connection and verify that the monitoring equipment receives a stable sensor signal. Check the measurement response against the expected operating conditions and confirm that alarm and monitoring functions behave correctly.

Record the cable part number and installation route in the maintenance documentation.

Compatible System Components

The PR9670/001-000 should be evaluated as part of a complete measurement system.

Component Function Compatibility Considerations
Epro eddy current probe Detects displacement or movement of a conductive target Confirm the exact probe model and cable interface
Signal conditioner / Proximitor Conditions the sensor signal for monitoring equipment Verify electrical and cable compatibility
Machinery monitoring rack Receives and evaluates measurement signals Confirm supported sensor type and input configuration
Monitoring software Displays trends, measurements, and alarms Depends on the monitoring platform and configured channels
Sensor mounting hardware Holds the probe in the required position Match the probe thread, dimensions, and mounting arrangement
Cable termination terminals Provide the electrical connection Follow the designated wiring diagram
Cable protection accessories Protect the installed cable from mechanical damage Select according to the installation environment

These are system-level components and are not necessarily included with the PR9670/001-000 cable.

Related Models and Replacement Considerations

The PR9670 series includes different cable configurations. Their differences should be reviewed before selecting a replacement.

Model / Configuration Documented Description
PR9670/000-000 5 m, two-core cable, electronics-side shielding, no protective hose, open cable end
PR9670/001-000 10 m, two-core cable, electronics-side shielding, no protective hose, open cable end
PR9670/003-000 20 m, two-core cable, electronics-side shielding, no protective hose, open cable end

The PR9670 series ordering matrix also identifies configuration differences involving shielding location, protective hose, cable length, connector type, and hazardous-area designation.

Before ordering a replacement, compare:

  • Cable length.
  • Number of cores.
  • Shielding arrangement.
  • Protective hose requirement.
  • Open cable end or connector termination.
  • Sensor-side and electronics-side interfaces.
  • Environmental and hazardous-area requirements.
  • Compatibility with the installed sensor and signal conditioner.

A cable with a different length or termination may require changes to the installation. Do not assume that a longer cable or a different shielding arrangement is automatically acceptable.

Key Advantages

Defined Cable Configuration

The PR9670/001-000 ordering information identifies a 10 m two-core cable configuration, making it easier to compare against an existing installation.

Electronics-Side Shielding

The documented shielding arrangement supports signal connection in industrial environments where electrical interference must be considered.

Open-End Termination

The open cable end allows connection to an installation designed for direct conductor termination, provided the wiring arrangement is compatible.

Integration into Machinery Monitoring Systems

The cable can support sensor signal transmission within suitable industrial machinery monitoring installations.

Replacement for Existing Configurations

Identifying the exact cable configuration can simplify maintenance planning and reduce the risk of selecting a cable with an incompatible length or termination.

Technical FAQs

1. What is the Epro PR9670/001-000?

It is a PR9670-series connection cable configuration associated with Epro machinery monitoring installations. Manufacturer ordering information identifies it as a 10 m, two-core cable with electronics-side shielding and an open cable end.

2. Is the PR9670/001-000 a complete eddy current sensor?

The manufacturer ordering reference identifies this part number as a cable configuration, not a complete eddy current probe. Confirm the supplied item and its included components before purchasing.

3. What is the cable length?

The documented cable length is 10 m.

4. How many cores does the cable have?

The documented configuration is two-core.

5. Does the cable include shielding?

Yes. The documented configuration has shielding on the electronics side. Follow the applicable wiring instructions for shield termination.

6. Does it include a protective hose?

The documented PR9670/001-000 configuration is listed without a protective hose.

7. What type of termination does it have?

The documented configuration has an open cable end rather than a factory-installed connector at that end.

8. Can it be used with any Epro eddy current probe?

No. Compatibility must be confirmed against the exact probe, signal conditioner, and monitoring-system connection requirements.

9. What should be checked before replacing an existing cable?

Check the complete part number, cable length, core count, shielding arrangement, protective hose, termination, and sensor/electronics interfaces.

10. What is the shipping weight?

The supplied product listing specifies a shipping weight of 3 kg. This should be treated as a shipping or listing value, not necessarily the actual weight of the cable alone.

Procurement and Maintenance Recommendations

When purchasing the Epro PR9670/001-000, begin by confirming whether the requirement is for the cable alone or for a complete sensor assembly. This distinction is particularly important because the manufacturer ordering reference identifies the part number as a 10 m cable configuration.

Ask the supplier to confirm the cable length, two-core construction, electronics-side shielding, absence of a protective hose, and open-end termination. If the application requires a sensor probe as well, obtain its separate model number and verify its compatibility with the monitoring electronics.

For replacement work, compare the existing cable with the proposed unit before installation. Check the cable label, conductor arrangement, shield termination, and physical condition. Store spare cables in a clean, dry location and protect them from crushing, excessive bending, and mechanical damage.

For critical machinery monitoring systems, verify the measurement signal after installation and document the cable route and connection details. Correct cable selection and installation help maintain a dependable signal path between the sensor and the monitoring equipment.

Conclusion

The Epro PR9670/001-000 is associated with the PR9670 series of industrial machinery monitoring connections. Its documented configuration is a 10 m, two-core cable with electronics-side shielding, no protective hose, and an open cable end.

Although it may be listed commercially as an Epro Eddy Current Sensor, the manufacturer ordering information identifies this specific designation as a connection cable configuration. Confirm whether the supplied item is cable-only or part of a complete sensor assembly before ordering. Matching the cable to the installed probe and signal-conditioning equipment is essential for reliable integration into industrial machinery monitoring systems.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501