Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Epro PR9670/000-000 Eddy Current Sensor is listed as an industrial sensing component associated with Epro machinery-monitoring equipment. Eddy-current sensing technology is used for non-contact measurement of metallic targets, making it useful in applications involving shaft movement, displacement, vibration, and position monitoring.
Unlike contact-based measurement devices, an eddy-current sensor operates without requiring the probe to physically touch the monitored metal surface. This measurement principle is particularly valuable in rotating machinery, where direct mechanical contact would introduce wear and could interfere with normal equipment operation.
In industrial machinery protection systems, displacement and vibration measurements provide important information about the mechanical condition of rotating equipment. Changes in shaft position, vibration amplitude, or operating behavior can indicate developing mechanical problems. When integrated with a suitable signal-conditioning and monitoring system, sensor measurements can support alarms, condition assessment, and maintenance planning.
The PR9670/000-000 designation requires particular attention during procurement. The PR9670 model family is associated with industrial sensing products, but the exact 000-000 suffix also appears in Emerson documentation for a PR9670 connection-cable configuration. Buyers should therefore confirm the actual product label, probe assembly, cable arrangement, and intended application before treating this item as a complete standalone sensor.
The sensor-head diameter is specified as optional in the supplied product information. This means the actual sensing-head configuration should be confirmed according to the required mounting arrangement and measurement application.
For industrial replacement projects, matching the complete sensor assembly is essential. A sensor probe, extension cable, connection cable, and signal-conditioning unit may be separate components, and they should not be assumed to be interchangeable merely because they share a product-family designation.
| Parameter | Specification |
|---|---|
| Brand | Epro |
| Product Model | PR9670/000-000 |
| Product Type | Eddy Current Sensor / Listed Sensor Assembly |
| Measurement Technology | Eddy-current sensing |
| Measurement Method | Non-contact measurement of metallic targets |
| Sensor Head Diameter | Optional |
| Shipping Weight | 3 kg |
| Bare Sensor Weight | Not specified |
| Physical Dimensions | Not specified |
| Target Material | Suitable conductive metallic target; confirm system requirements |
| Signal Conditioning | Requires a compatible measurement interface where applicable |
| Typical Measurement Applications | Shaft displacement, vibration, and position monitoring |
| Typical Equipment | Rotating machinery and industrial mechanical systems |
| Product Configuration | Verify exact probe, cable, and connector arrangement |
Important identification note: The PR9670/000-000 designation is also documented as a connection-cable part number in an Emerson document. Confirm whether the supplied item is a complete sensor assembly, a cable, or a configured sensing package before ordering.
The operating principle of an eddy-current sensor is based on electromagnetic induction. A sensing coil inside the probe generates an alternating electromagnetic field. When a conductive metal target enters this field, electrical currents known as eddy currents are induced in the target material.
These currents create a secondary electromagnetic field that interacts with the original field produced by the probe. The resulting change in the electrical characteristics of the sensing circuit is related to the distance between the probe and the target.
A suitable signal-conditioning unit processes this change and converts it into a usable measurement signal.
The probe contains a coil driven by an alternating electrical signal. This produces an electromagnetic field around the sensing face.
The field extends toward the monitored metallic surface. The geometry of the probe, its operating frequency, and the target material influence the sensor’s response.
When a conductive target is placed within the electromagnetic field, circulating electrical currents are induced near the target surface.
The strength and distribution of these currents depend on several factors, including:
Because these factors influence the measurement response, the sensor must be calibrated for the intended target material and measurement arrangement.
The induced eddy currents affect the probe’s electrical characteristics. A compatible signal conditioner evaluates the change and converts it into a measurement output.
The output may be used by a machinery-monitoring system, protection module, or other compatible measurement equipment.
The exact output type, sensitivity, linear range, and electrical interface must be confirmed from the documentation for the complete sensor assembly. These values should not be inferred from the model-family name alone.
When the probe is installed facing a suitable metallic target, changes in the gap between the probe and the target can be measured.
In rotating machinery, the target may be a shaft surface. The resulting measurement can help identify changes in shaft position or dynamic movement.
With appropriate monitoring equipment, the measurement can be evaluated continuously and compared against established operating limits.
A properly configured displacement-measurement system can provide dynamic shaft movement information. Monitoring this information over time can help maintenance teams identify unusual vibration patterns, mechanical instability, or changes in operating conditions.
The sensor itself provides the measurement input. Detailed vibration analysis, alarm processing, and machinery protection functions depend on the connected monitoring system.
Eddy-current sensors are important components in machinery condition-monitoring installations. They provide measurement information that can be processed by dedicated monitoring hardware.
A non-contact probe can monitor the distance between its sensing face and a metallic shaft surface. Changes in this distance may indicate shaft movement or displacement.
This measurement is particularly useful in equipment where shaft position must be observed during operation.
When installed in an appropriate orientation, displacement probes can measure radial movement of a rotating shaft.
Two measurement channels arranged at suitable angles may provide additional information about shaft movement. The exact installation arrangement depends on the machine design and monitoring requirements.
In suitable installations, an eddy-current measurement system can monitor axial shaft movement. This is important in machinery where excessive axial displacement may affect bearings, seals, thrust components, or internal clearances.
The sensor arrangement must be designed around the machine’s actual measurement points and allowable movement.
The sensor must be paired with a compatible signal-conditioning and monitoring interface. The interface supplies the appropriate excitation, processes the probe response, and provides measurement information to the monitoring system.
Before integrating the PR9670/000-000, confirm the exact electrical characteristics and cable requirements. A cable-only component cannot perform the complete sensing function without the appropriate probe and electronic interface.
Eddy-current measurement technology is widely used in industrial machinery where non-contact monitoring of metallic targets is required.
Steam turbines operate at high rotational speeds and require continuous monitoring of important mechanical parameters.
Suitable displacement probes can provide shaft movement information that helps operators identify abnormal vibration or changes in shaft position. This information can be incorporated into machinery protection and condition-monitoring systems.
Gas turbines contain rotating assemblies that operate under demanding mechanical and thermal conditions.
Non-contact displacement measurement can support monitoring of shaft behavior and help maintenance teams evaluate changes in machine condition.
Sensor selection must consider the installation environment, target material, operating temperature, and measurement-system requirements.
Large compressors are used in chemical processing, petrochemical facilities, gas transportation, and manufacturing plants.
Monitoring shaft movement and vibration can help identify developing mechanical problems, including rotor imbalance, misalignment, and bearing-related abnormalities.
An appropriately installed eddy-current sensor can provide measurement information for these monitoring tasks.
Industrial pumps often operate continuously and may experience changes in load, pressure, or mechanical condition.
Where the pump design and monitoring arrangement require shaft displacement measurements, non-contact sensing can provide information about rotor movement.
The probe must be installed with the correct clearance and orientation for the intended measurement point.
Large motors and generators contain rotating shafts and bearings that may require continuous condition monitoring.
Displacement measurements can help engineers observe shaft movement and identify changes in mechanical behavior.
The monitoring system should be configured according to the machine’s operating speed, shaft material, and mechanical design.
Gearboxes and industrial drive assemblies may experience vibration, shaft movement, and mechanical loading changes.
Suitable non-contact measurement systems can provide additional information for machinery diagnostics and maintenance planning.
The installation must account for target accessibility, shaft geometry, and the required measurement range.
Correct installation is essential for measurement stability and reliable machinery monitoring.
Before installation, confirm whether the PR9670/000-000 supplied is a sensor probe, connection cable, or complete configured assembly.
Check the product label, connector type, cable length, probe construction, and associated electronic interface. This step is particularly important because the exact part-number suffix appears in documentation associated with a connection cable.
Do not connect an unidentified component to a monitoring system until its electrical function has been established.
Eddy-current sensors operate with conductive targets. Target material influences the sensor response and calibration.
Use the target material specified for the complete measurement system. If the target material changes, the original calibration may no longer provide the intended measurement accuracy.
The sensor-head diameter is optional according to the supplied listing information.
The selected diameter should be appropriate for the available mounting space, target dimensions, required measurement range, and mechanical clearances.
A larger sensing head is not automatically suitable for every application. Probe geometry and the measurement system must be considered together.
The distance between the probe face and the target must remain within the specified linear measurement range of the complete sensing system.
The correct gap should be established using the manufacturer’s installation and calibration instructions.
Incorrect probe spacing can result in an unstable output, reduced measurement range, or an inability to measure the expected shaft movement accurately.
The probe should be mounted securely to prevent unwanted movement during machine operation.
Cable routing should minimize mechanical stress, vibration-related damage, and interference from nearby power conductors. Follow the manufacturer’s minimum bending radius and connector-handling instructions.
Where the installation uses a separate extension or connection cable, confirm the total permitted cable length and the correct cable type.
The probe must be connected to a compatible signal-conditioning interface where required by the sensing system.
Verify the connector arrangement, electrical characteristics, and system compatibility before applying power.
Do not assume that all Epro probes and signal conditioners use identical electrical interfaces.
After installation, verify the probe gap, target material, signal response, and measurement direction.
Check the measurement output across the expected operating range. Compare the results with the system’s calibration data and confirm that the connected monitoring equipment displays stable readings.
Record the installation details and calibration information for future maintenance.
An eddy-current sensor normally operates as part of a complete measurement chain.
| Component | Function | Compatibility Considerations |
|---|---|---|
| Eddy-current probe | Detects changes in distance to a conductive target | Confirm probe type, diameter, and electrical characteristics |
| Extension cable | Connects the probe to the signal-conditioning equipment | Verify cable type, connector, and permitted length |
| Connection cable | Provides the required electrical connection | Confirm whether PR9670/000-000 is supplied as a cable component |
| Signal conditioner | Processes the probe response into a usable measurement signal | Must match the probe and cable configuration |
| Machinery-monitoring module | Processes measurement data and supports monitoring functions | Verify input characteristics and system compatibility |
| Vibration monitoring rack | Receives and evaluates machinery measurement signals | Confirm supported sensor and signal-conditioner combinations |
| Mounting bracket | Holds the probe in the required position | Must provide stable positioning and correct alignment |
| Metallic measurement target | Provides the surface being monitored | Confirm material properties and target geometry |
| Monitoring software | Displays trends, alarms, and measurement information | Configure according to the connected monitoring hardware |
These are functional categories rather than a declaration that every listed component is included with the PR9670/000-000. The complete measurement-system configuration should be checked before procurement.
When replacing an Epro sensor or related cable, the correct substitute must be selected according to the complete measurement-system configuration.
| Alternative Model or Component | Description | Replacement Considerations |
|---|---|---|
| Epro PR9670/001-000 | Related PR9670 family designation | Confirm whether it is a probe or another configured component |
| Epro PR9670/002-000 | Related PR9670 family designation | Verify connector and electrical configuration |
| Epro PR9670/003-000 | Related PR9670 family designation | Compare the complete part number and assembly details |
| Epro PR9670/110-100 | PR9670 family sensor listing | Confirm probe dimensions and measurement characteristics |
| Epro PR9670/113-100 | PR9670 family sensor listing | Verify sensing range, probe diameter, and system compatibility |
| Epro PR6423 Series | Eddy-current displacement sensor family | Requires a complete comparison of probe and signal-conditioning specifications |
| Epro PR6424 Series | Eddy-current displacement sensor family | Not automatically interchangeable with PR9670 components |
Before selecting a replacement, compare:
A sensor from another product family should not be treated as a direct substitute without checking the complete measurement chain.
Eddy-current technology measures the distance to a conductive target without physical contact. This avoids direct mechanical wear between the sensing probe and the monitored surface.
The measurement principle is appropriate for monitoring shaft movement and displacement in rotating machinery when the correct probe and monitoring interface are used.
When connected to a compatible monitoring system, the sensor can provide measurement information during normal machine operation.
Displacement and vibration measurements can contribute to machinery protection strategies by providing data for alarm and shutdown logic.
The supplied listing identifies the sensor-head diameter as optional. This allows the required sensing-head configuration to be specified according to the intended installation, subject to the manufacturer’s available options.
Eddy-current sensors can be incorporated into broader machinery-monitoring arrangements using compatible signal conditioners, monitoring modules, and display systems.
Measurement trends can help maintenance teams identify changes in machine behavior and investigate developing mechanical issues before they cause serious equipment problems.
It is listed as an Epro Eddy Current Sensor product. However, the exact 000-000 designation also appears in Emerson documentation for a PR9670 connection cable. Confirm the supplied item’s actual configuration before purchase.
The sensor generates an alternating electromagnetic field. When a conductive metallic target enters this field, eddy currents are induced in the target. Changes in the electromagnetic interaction are processed by suitable electronics to determine the distance between the probe and target.
No. Eddy-current sensing is a non-contact measurement method. The probe measures the distance to a suitable conductive target without touching it.
The supplied product information identifies the sensor-head diameter as optional. The actual diameter should be confirmed according to the required installation and sensor configuration.
The supplied shipping weight is 3 kg. This should not automatically be interpreted as the weight of the bare probe, since packaging and accessories may contribute to the shipment weight.
An appropriately configured eddy-current displacement system can measure dynamic shaft movement. The resulting signal can be processed by compatible monitoring equipment for vibration assessment.
The complete measurement arrangement depends on the specific product configuration. Many eddy-current measurement systems require compatible signal-conditioning electronics to excite the probe and convert its response into a usable output.
Typical applications include steam and gas turbines, compressors, pumps, generators, motors, gearboxes, and other rotating industrial machinery.
This must be confirmed from the supplied product label and documentation. The exact designation also appears in Emerson documentation as a PR9670 connection cable, so buyers should not assume it represents a complete probe assembly.
Verify the complete model number, product type, probe diameter, cable configuration, connector, signal-conditioning interface, and monitoring-system compatibility. For critical machinery, compare the replacement with the original installed component.
When purchasing the Epro PR9670/000-000, begin by identifying the exact component being supplied. Request a clear photograph of the product label, connectors, probe head, and cable arrangement where applicable.
This is especially important for the 000-000 suffix because it appears in connection-cable documentation. A cable component and a complete eddy-current probe assembly perform different functions and should not be listed as interchangeable products.
For replacement orders, compare the original installation records with the supplier’s product description. Confirm the sensor-head diameter, cable length, connector, target material, and compatible signal-conditioning equipment.
For storage and handling, protect connectors and cable ends from contamination, moisture, and mechanical damage. Avoid pulling or sharply bending cables. Keep the sensing face clean and protect it from impact.
During maintenance, inspect the mounting arrangement, cable condition, connector contacts, and signal stability. If the measurement output changes unexpectedly, check the target surface, probe gap, cable connection, signal conditioner, and monitoring-system configuration before replacing the sensor.
Keep calibration information and installation records with the machinery maintenance documentation. These records help ensure that future replacement components match the original measurement arrangement.
The Epro PR9670/000-000 is listed as an Eddy Current Sensor associated with industrial machinery monitoring applications. Eddy-current technology provides non-contact measurement of conductive targets and can support shaft displacement, vibration, and position monitoring when used with a compatible signal-conditioning and monitoring system.
The supplied product information identifies an optional sensor-head diameter and a shipping weight of 3 kg. However, the exact PR9670/000-000 designation also appears in connection-cable documentation. Verifying whether the supplied item is a complete sensor assembly or a cable component is therefore essential before procurement.
For industrial maintenance and machinery-protection applications, correct identification, cable matching, probe configuration, and system compatibility are key to achieving reliable measurement performance.