• Allen Bradley 1746-FIO4I SLC 500 Fast Analog I/O Module
  • Allen Bradley 1746-FIO4I SLC 500 Fast Analog I/O Module
  • Allen Bradley 1746-FIO4I SLC 500 Fast Analog I/O Module
  • Allen Bradley 1746-FIO4I SLC 500 Fast Analog I/O Module
Product Overview The Allen-Bradley 1746-FIO4I SLC 500 Fast Analog I/O Module is a combination analog input and output module designed for industrial automation systems using the Allen-Bradley SLC 500 pr……
Allen Bradley 1746-FIO4I SLC 500 Fast Analog I/O Module
  • Allen Bradley
  • 1746-FIO4I
  • SLC 500 Fast Analog I/O Module
  • USA
  • 144.5 × 34.6 × 130.18 mm
  • 0.36 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 4

Our advantage

Allen Bradley 1746-FIO4I SLC 500 Fast Analog I/O Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Allen Bradley 1746-FIO4I SLC 500 Fast Analog I/O Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Allen Bradley 1746-FIO4I SLC 500 Fast Analog I/O Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Allen Bradley 1746-FIO4I SLC 500 Fast Analog I/O Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Allen-Bradley 1746-FIO4I SLC 500 Fast Analog I/O Module is a combination analog input and output module designed for industrial automation systems using the Allen-Bradley SLC 500 programmable logic controller platform. Manufactured by Rockwell Automation, this module provides fast-response analog signal processing for applications that require continuous measurement and control of industrial variables.

Unlike digital I/O modules, which process discrete ON/OFF signals, analog I/O modules handle continuously varying signals from instruments and control devices. These signals can represent process variables such as temperature, pressure, flow, level, speed, and other measurable conditions.

The 1746-FIO4I provides two differential analog input channels and two analog current output channels. Each input channel can be configured independently for voltage or current operation. This flexibility allows the module to receive different types of industrial instrument signals while providing current outputs for connected control devices.

The input channels support signals such as 0–10 V DC and 0–20 mA, while the two output channels provide 0–20 mA current signals. The module is designed for applications where relatively fast analog response is important, including process monitoring, pressure regulation, flow control, and machine automation.

Installed in a compatible 1746 SLC 500 I/O chassis, the 1746-FIO4I exchanges analog data with the controller through the backplane. The PLC can process incoming measurements and generate output commands according to the control logic programmed by the system engineer.

For industrial maintenance and replacement projects, this module remains relevant to facilities operating legacy SLC 500 systems. Its channel configuration, signal ranges, and fast-response characteristics make accurate model identification essential when replacing existing analog I/O equipment.

Technical Specifications

Parameter Specification
Brand Allen-Bradley
Manufacturer Rockwell Automation
Model 1746-FIO4I
Product Series SLC 500
Product Type Fast Analog Input/Output Module
Module Configuration 2 Analog Inputs + 2 Current Outputs
Number of Input Channels 2 differential inputs
Number of Output Channels 2 current outputs
Input Signal Type Voltage or current, selectable per channel
Voltage Input Range 0–10 V DC
Current Input Range 0–20 mA nominal
Current Output Range 0–20 mA
Input Resolution 12-bit
Output Resolution 14-bit
Input Bandwidth 7 kHz
Backplane Current at 5 V DC 55 mA
Backplane Current at 24 V DC 150 mA
Installation One slot in a 1746 I/O chassis
Terminal Block Removable
Recommended Cable Shielded cable
Dimensions Provided 144.5 × 34.6 × 130.18 mm
Weight Provided 0.36 kg
Platform Compatibility Allen-Bradley SLC 500
Product Lifecycle Discontinued

Note: Specifications are based on the 1746-FIO4I module configuration. Confirm the actual module series, terminal block, and installation requirements before replacement.

Function and Working Principle

The 1746-FIO4I performs two main functions within an industrial control system: converting analog input signals into digital data for PLC processing and converting digital controller commands into analog current output signals.

These functions allow a SLC 500 controller to monitor real-world process conditions and regulate connected equipment.

1. Fast Analog Signal Acquisition

The module receives analog signals from field instruments such as pressure transmitters, flow meters, and other measurement devices.

Each input channel is differential and can be configured for voltage or current operation. This allows engineers to select the appropriate input mode according to the connected instrument.

For example, a pressure transmitter may provide a 4–20 mA signal representing the pressure inside a pipeline. The 1746-FIO4I receives the current signal, converts it into digital data, and transfers the resulting value to the SLC 500 processor.

The controller can then compare the measured pressure with a target value and determine whether an adjustment is required.

2. Analog-to-Digital Conversion

The input circuitry converts incoming electrical signals into digital values that the PLC can process.

The 1746-FIO4I uses 12-bit input conversion. The resulting data is transferred through the SLC 500 backplane and made available in the controller’s input image.

The PLC program can use these values for calculations, alarm thresholds, process monitoring, and automatic control sequences.

Fast signal acquisition is particularly useful in applications where process conditions change quickly and the control system must respond without unnecessary delay.

3. Analog Current Output

The module also provides two analog current output channels. These outputs allow the SLC 500 controller to send continuous control signals to compatible field devices.

For example, a PLC may calculate the required pump speed or valve position based on the difference between a measured process variable and its target value. The controller then writes an output value that the 1746-FIO4I converts into a corresponding current signal.

The available current output range is 0–20 mA. Connected equipment must be configured for the correct signal range.

4. Independent Input Configuration

Each input channel can be selected for voltage or current operation. This allows two different signal types to be connected to the same module when the application requires it.

The input selection is configured through the module’s switch assembly. Correct switch settings are essential because the electrical input configuration must match the connected instrument.

5. Fast Response for Process Control

The 1746-FIO4I is designed for faster analog response than many standard analog modules.

Its fast-response characteristics make it suitable for applications where pressure, flow, or other process measurements change over relatively short periods.

However, fast analog response also requires careful attention to electrical noise. Proper shielding, grounding, cable routing, and signal wiring help maintain measurement stability.

Role in Industrial Control Systems

The 1746-FIO4I serves as an interface between field instruments, control equipment, and the SLC 500 processor. It allows the controller to receive continuous measurement signals and issue analog control commands.

PLC Integration

The module communicates with the SLC 500 processor through the 1746 chassis backplane.

The controller reads input values from connected instruments and uses its programmed logic to determine the appropriate output response. This creates a continuous control sequence between measurement devices and final control elements.

Typical PLC operations include:

  • Reading analog process measurements.
  • Comparing actual values with target values.
  • Calculating control adjustments.
  • Sending analog output commands.
  • Monitoring operating conditions.
  • Activating alarms when configured limits are exceeded.

Process Instrument Integration

The two differential input channels can connect to compatible voltage or current transmitters.

Common examples include:

  • Pressure transmitters.
  • Flow measurement instruments.
  • Level transmitters.
  • Temperature transmitters with compatible signal conditioners.
  • Industrial monitoring devices.

The two current output channels can connect to compatible control devices, including current-controlled valves, actuators, and other equipment that accepts the module’s output range.

The module does not provide loop power for analog input transmitters. Field instruments requiring external loop power must be supplied by an appropriate power source.

HMI and Operator Monitoring

In a typical SLC 500 installation, an HMI communicates with the PLC and displays process values, alarms, and equipment status.

The HMI can present analog measurements received through the 1746-FIO4I and allow operators to modify process targets or operating commands through the controller program.

This arrangement helps operators monitor process conditions without directly interacting with the analog module.

Integration with Existing SLC 500 Systems

The 1746-FIO4I is designed for the SLC 500 platform and occupies one slot in a compatible 1746 I/O chassis.

When adding or replacing the module, engineers should verify the chassis configuration, available slot, power supply capacity, controller compatibility, and program addressing.

The module requires backplane current of 55 mA at 5 V DC and 150 mA at 24 V DC. The power supply must have sufficient capacity for the complete rack configuration.

Industrial Applications

The 1746-FIO4I can support a range of industrial applications involving fast analog measurement and current-based control signals.

1. Pressure Monitoring and Regulation

Industrial pressure systems often use transmitters to provide continuous pressure measurements.

The module receives the transmitter signal and transfers the corresponding digital value to the SLC 500 processor. The controller can compare this value with a configured pressure target and adjust a connected control device through an analog output.

This arrangement is useful in pumping systems, hydraulic equipment, and industrial process lines.

2. Flow Control Systems

Flow measurement instruments can provide analog signals representing the volume or rate of fluid moving through a pipeline.

The 1746-FIO4I allows the PLC to monitor these signals and generate current outputs for compatible control valves or other regulating equipment.

This type of control can be used in water treatment, chemical processing, and industrial fluid-handling systems.

3. Temperature Monitoring

Temperature transmitters and signal conditioners can provide voltage or current signals representing measured temperatures.

The module receives these signals and transfers the values to the PLC for monitoring and control.

In suitable systems, the controller can use the measurements to adjust heating or cooling equipment through connected analog output devices.

4. Pump and Motor Process Control

Industrial pumps and other motor-driven systems often require coordination between process measurements and motor operation.

The module can provide analog measurements to the PLC and deliver current output commands to compatible control equipment.

For variable-speed motor control, the connected drive must support the selected analog reference signal and be configured for the correct input range.

5. Manufacturing and Production Equipment

Manufacturing machinery may require continuous monitoring of pressure, position-related signals, temperature, or other process variables.

The 1746-FIO4I provides a compact combination of analog input and output channels for suitable SLC 500 applications.

Its fast-response design can support equipment where analog signals must be acquired and updated quickly.

6. Water and Wastewater Treatment

Water treatment systems use analog instruments to monitor flow, pressure, tank conditions, and other process variables.

A SLC 500 controller equipped with the 1746-FIO4I can process compatible instrument signals and send current output commands to regulating devices.

This arrangement can support automated pumping, chemical dosing, and flow-management processes when the connected instruments and control devices meet the module’s electrical requirements.

Installation and System Integration

Proper installation is essential for reliable signal measurement and stable analog output operation.

1. Verify SLC 500 Chassis Compatibility

Before installation, confirm that the module is being used with a compatible 1746 SLC 500 I/O chassis.

The 1746-FIO4I occupies one slot. Check the available slot, chassis configuration, processor arrangement, and power supply capacity before adding the module.

The rack power supply must support the module’s backplane current requirements in addition to the demands of all other installed modules.

2. Configure the Input Channels

The two input channels can be independently configured for voltage or current operation using the module’s switch assembly.

Before connecting field instruments, verify the selected mode for each channel.

An incorrect configuration can result in inaccurate readings or improper signal interpretation. The input mode must match the electrical output of the connected transmitter or signal conditioner.

3. Use Shielded Analog Cables

Fast analog signals can be more sensitive to electrical interference than heavily filtered signals.

Use suitable shielded cable and follow the manufacturer’s grounding recommendations. The module documentation recommends shielded Belden #8761 cable.

Route analog signal wiring away from high-voltage conductors, motor cables, contactors, and other sources of electrical noise.

4. Connect Field Instruments Correctly

Check transmitter polarity, signal range, terminal assignments, and grounding before wiring the module.

The module does not provide loop power for analog input devices. External power must be provided where required by the connected instrument.

Also verify that connected output devices are compatible with the module’s 0–20 mA current output range.

5. Install the Removable Terminal Block

The 1746-FIO4I uses a removable terminal block, which simplifies wiring and maintenance.

Confirm that the terminal block is correctly matched to the module and securely installed. Inspect terminal connections for loose conductors, damaged insulation, and incorrect wiring.

6. Configure PLC Data Handling

After installation, configure the SLC 500 program to read the module’s input data and write the required output values.

The program should account for the selected signal ranges, scaling factors, engineering units, alarm thresholds, and control limits.

For example, a 4–20 mA pressure transmitter may require scaling from the module’s raw input counts into the corresponding engineering pressure range.

7. Test Analog Inputs and Outputs

Commissioning should include checks of both input and output channels.

Verify that the input values correspond to the actual field signals and that the output current matches the PLC command.

Test the system under normal operating conditions and confirm that alarms, interlocks, and process responses behave as expected.

Compatible System Components

The 1746-FIO4I is intended for integration into an SLC 500 control system. The following components may be used in a typical installation, subject to hardware and electrical compatibility.

Component Function Compatibility Considerations
SLC 500 Processor Executes PLC logic and processes analog data Confirm processor and chassis configuration
1746 I/O Chassis Provides module mounting and backplane communication One slot is required for the 1746-FIO4I
SLC 500 Power Supply Supplies backplane power Must support total rack current requirements
1746-FIO4I Module Processes analog input and current output signals Two differential inputs and two current outputs
1746-RT27 Terminal Block Provides field wiring connections Verify the correct terminal block for the module
Pressure Transmitter Supplies pressure measurement signals Confirm voltage or current output compatibility
Flow Transmitter Supplies flow measurement signals Match the input signal range and wiring
Current-Controlled Valve Receives analog current commands Confirm 0–20 mA compatibility
Variable Frequency Drive Controls motor speed Verify that the drive accepts the selected analog reference
HMI Displays process values and operator commands Typically communicates through the SLC 500 controller
Shielded Instrument Cable Carries analog signals Follow cable and grounding recommendations

The components listed above are examples of equipment used in an industrial analog control system. They are not necessarily supplied with the 1746-FIO4I module.

Alternative Models and Replacement Considerations

The 1746-FIO4I is a specialized fast analog combination module. When selecting an alternative, engineers should consider both the number of channels and the electrical characteristics of the input and output signals.

Alternative Model Product Type Replacement Considerations
1746-FIO4V Fast Analog I/O Module Similar input configuration but provides voltage outputs instead of current outputs
1746-NIO4I Analog Combination Module Provides analog input and current output functions, but response and performance characteristics differ
1746-NIO4V Analog Combination Module Provides analog input and voltage output functions
1746-NI4 Analog Input Module Input-only module; additional hardware is needed for analog output
1746-NO4I Analog Current Output Module Provides current output channels but does not replace the input function
5069 Compact 5000 I/O Modules Modern I/O Platform May be considered as part of a broader migration from SLC 500 to Logix-based systems

A replacement should be evaluated according to the following factors:

  • Number of analog input and output channels.
  • Voltage and current signal ranges.
  • Differential input requirements.
  • Input and output resolution.
  • Response time and bandwidth.
  • Backplane power requirements.
  • Terminal block and wiring arrangement.
  • PLC platform and program compatibility.
  • Field instrument and control-device requirements.

The 1746-FIO4V is not a direct replacement for the FIO4I when current outputs are required, because the FIO4V provides voltage outputs. Similarly, a standard analog module may not provide the same response characteristics as the fast analog FIO4I.

When migrating to a newer control platform, engineers should also consider I/O conversion hardware, PLC program changes, signal scaling, and commissioning requirements.

Key Advantages

Combined Analog Input and Output

The module provides two differential analog input channels and two current output channels in one compact SLC 500 module.

Selectable Input Signal Types

Each input channel can be configured for voltage or current operation, allowing the module to work with different types of compatible field instruments.

Fast Analog Response

Its fast-response design supports applications where process measurements and control signals need to be updated quickly.

12-Bit Input Resolution

The analog input conversion provides 12-bit resolution for processing incoming measurement signals.

14-Bit Output Resolution

The current output circuitry provides 14-bit resolution, supporting detailed analog command generation.

SLC 500 Backplane Integration

The module installs directly into a compatible 1746 I/O chassis and exchanges data with the SLC 500 processor through the backplane.

Removable Terminal Block

The removable terminal block supports convenient field wiring and maintenance procedures.

Flexible Process Applications

The combination of voltage/current inputs and current outputs makes the module suitable for a range of industrial measurement and control tasks.

Technical FAQs

1. What is the Allen-Bradley 1746-FIO4I?

The 1746-FIO4I is a fast analog input/output module for the Allen-Bradley SLC 500 platform. It provides two differential analog inputs and two analog current outputs.

2. How many input and output channels does it have?

It provides two analog input channels and two current output channels, giving it a four-channel combination configuration.

3. What input signals does the 1746-FIO4I support?

Each input channel can be configured for voltage or current operation. Typical input ranges include 0–10 V DC and 0–20 mA.

4. What is the analog output range?

The module provides two current output channels with a nominal range of 0–20 mA.

5. What is the input resolution?

The analog input conversion uses 12-bit resolution. This allows the module to convert incoming analog measurements into digital values for PLC processing.

6. What is the output resolution?

The analog current output circuitry provides 14-bit resolution.

7. Which PLC platform is compatible with this module?

The 1746-FIO4I is designed for the Allen-Bradley SLC 500 platform and installs in a compatible 1746 I/O chassis.

8. Does the module provide power to analog transmitters?

No. The module does not provide loop power for analog input instruments. External power must be supplied according to the connected transmitter’s requirements.

9. Why is shielded cable recommended?

Fast analog signals can be affected by electrical interference. Shielded cable, suitable grounding, and separation from power wiring help reduce noise and improve measurement stability.

10. Is the 1746-FIO4I still in production?

The 1746 SLC I/O product family has been discontinued. The 1746-FIO4I is therefore generally sourced through existing inventories, surplus stock, or specialist industrial spare-parts suppliers. Check the condition and exact model before purchasing.

Procurement and Maintenance Recommendations

When purchasing the Allen-Bradley 1746-FIO4I, verify the complete catalog number and confirm that the module matches the existing SLC 500 system. Check the number of input and output channels, voltage and current ranges, terminal block arrangement, and module condition.

For used or refurbished units, request clear photographs of the front label, side identification markings, terminal area, and connector contacts. Where the module is intended for a critical process, request functional test information covering both analog input and output channels.

During maintenance, inspect the terminal block, field wiring, shielding, and grounding. Loose connections or electrical interference can affect analog measurement accuracy. Periodically verify channel calibration according to the application requirements and manufacturer documentation.

When replacing a module, record the input channel configuration and relevant PLC scaling parameters before removing the existing unit. After installation, test each channel individually and confirm that the displayed engineering values match the actual field signals.

For long-term system planning, facilities operating SLC 500 equipment should also evaluate spare-part availability and potential migration options. A transition to a newer I/O platform may require changes to hardware, software, wiring, and commissioning procedures.

Conclusion

The Allen-Bradley 1746-FIO4I SLC 500 Fast Analog I/O Module is designed for industrial applications requiring fast analog measurement and current-based control. Its two differential input channels support selectable voltage or current operation, while its two current output channels provide 0–20 mA signals for compatible control devices.

With 12-bit input resolution, 14-bit output resolution, and direct integration into a compatible 1746 SLC 500 chassis, the module provides a practical combination of measurement and control functions for legacy industrial automation systems.

For replacement and maintenance projects, engineers should verify signal ranges, channel configuration, terminal connections, backplane power requirements, and PLC compatibility before installation.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501