The Ingersoll Rand 47588445001 24509184 Valve Repair Kit is a service component for the temperature control valve used in compatible rotary screw air compressors. The kit is associated with the compressor’s thermal management and lubricant circulation system, where valve operation influences how oil moves through the cooling circuit as operating conditions change.
In an oil-injected screw compressor, lubricant performs several functions at once: it lubricates moving components, helps seal the compression chamber, and carries heat away from the air end. The temperature control valve regulates the oil flow path according to temperature conditions, helping the compressor reach and maintain its intended operating range.
Internal valve components can deteriorate through repeated thermal cycling, contamination, seal wear, and extended service. When the valve no longer responds correctly, the compressor may experience abnormal oil temperature behavior or inconsistent routing of lubricant through the cooling circuit. A repair kit provides replacement components for servicing the valve assembly without automatically replacing the entire valve.
Part number 24509184 is identified in Ingersoll Rand parts listings as a temperature control valve service kit. The associated reference 47588445001 identifies the kit in replacement-parts catalogs. It is distinct from a minimum pressure valve repair kit, an oil filter, or an air/oil separator, each of which serves a different function in the compressor.
During maintenance, the condition of the valve body, sealing surfaces, and internal moving components determines whether a repair is appropriate. Replacing serviceable internal parts can restore the intended valve operation when wear is responsible for the fault. Problems caused by a damaged housing, a restricted oil passage, or another cooling-system component require separate attention.
For compressor maintenance teams, the 24509184 kit is relevant to planned servicing and troubleshooting of the temperature control valve. Correct valve operation helps maintain the intended lubricant flow path and supports thermal management during changing compressor loads.
| Parameter | Specification |
|---|---|
| Manufacturer | Ingersoll Rand |
| Model Reference | 47588445001 |
| Part Number | 24509184 |
| Product Name | Valve Repair Kit |
| Product Type | Temperature Control Valve Service Kit |
| Product Category | Rotary Screw Air Compressor Spare Part |
| Primary Function | Servicing the temperature control valve assembly |
| System Application | Compressor lubricant temperature regulation |
| Valve Function | Regulates lubricant flow according to operating temperature |
| Installation Location | Compressor oil temperature control circuit |
| Maintenance Type | Valve repair and component replacement |
| Dimensions | 100 × 15 × 80 mm |
| Weight | 0.15 kg |
The 24509184 Valve Repair Kit is used to service the temperature control valve that manages lubricant flow in the compressor’s thermal management circuit. The valve responds to oil temperature and directs lubricant through the applicable flow paths.
Compressor Air End → Temperature Control Valve → Oil Cooling Circuit → Lubricant Return Path
When the compressor starts from a relatively cool condition, the temperature control valve regulates the oil flow path to help the system reach its required operating temperature. As the lubricant warms, the valve changes its position according to its internal temperature-responsive mechanism, directing oil through the cooling circuit as required.
This regulation helps prevent the lubricant from remaining excessively cool or becoming too hot under normal operating conditions. Maintaining the intended temperature range supports lubrication, moisture management, and the overall operating condition of the compressor.
Wear or damage to internal seals and moving components can affect the valve’s response. A valve that sticks, leaks internally, or fails to route oil correctly may contribute to abnormal temperature behavior. The repair kit provides service components for the applicable valve assembly, allowing worn parts to be replaced where the housing and other components remain serviceable.
After servicing, the valve’s operation should be evaluated as part of the compressor’s approved commissioning procedure. Oil temperature, cooling performance, and available operating indications can help establish whether the original problem has been corrected.
The temperature control valve is part of the compressor’s lubricant circulation and thermal management arrangement. The 24509184 repair kit supports maintenance of this valve, while the oil cooler, oil filter, and air/oil separator perform separate functions within the wider compressor system.
Compressor Air End → Temperature Control Valve → Oil Cooler and Circulation Circuit → Compressor Lubrication System
| System Component | Function |
|---|---|
| Ingersoll Rand 24509184 Valve Repair Kit | Provides service components for the compatible temperature control valve |
| Temperature Control Valve | Regulates lubricant flow according to operating temperature |
| Compressor Lubricant | Provides lubrication, sealing, and heat transfer |
| Oil Cooler | Removes heat from circulating lubricant |
| Oil Filter | Removes particulate contaminants from the oil circuit |
| Oil Separator Element | Separates entrained oil from compressed air |
| Oil Return Circuit | Returns recovered oil to the lubrication system |
| Temperature Monitoring Device | Measures oil or system temperature where fitted |
| Compressor Controller | Coordinates operation and monitors available operating signals |
| Rotary Screw Air End | Compresses air and transfers heat to the lubricant |
| Application | Typical Use |
|---|---|
| Industrial Manufacturing | Maintaining temperature control valve operation in compressor systems supplying production machinery |
| Automotive Production | Supporting lubricant temperature regulation in compressed-air installations |
| Metalworking Facilities | Servicing temperature control valves on compressors supplying machine tools |
| Packaging Plants | Maintaining compressor cooling performance for automated production equipment |
| Process Manufacturing | Supporting lubricant circulation and temperature management |
| Central Compressor Rooms | Maintaining valve operation in shared compressed-air systems |
| Continuous-Operation Facilities | Servicing temperature control components during planned maintenance |
| Industrial Utility Rooms | Repairing compatible compressor oil temperature control assemblies |
| Compressor Maintenance Workshops | Replacing worn valve components during troubleshooting |
| Rotary Screw Compressor Installations | Maintaining the thermal management circuit in compatible oil-injected machines |
| Component | Function |
|---|---|
| Ingersoll Rand 24509184 Valve Repair Kit | Services the compatible temperature control valve assembly |
| Temperature Control Valve | Regulates lubricant flow according to temperature conditions |
| Oil Cooler | Removes heat from circulating compressor lubricant |
| Ingersoll Rand 24900433 Oil Filter | Filters particulate contaminants from circulating lubricant |
| Ingersoll Rand 24900342 Air Oil Separator | Separates oil from compressed air |
| Ingersoll Rand 48958201 Air Filter | Filters incoming air before compression |
| Ingersoll Rand 49007941 Pre-Filter Pad | Provides preliminary intake filtration in compatible configurations |
| Compressor Lubricant | Supports lubrication, sealing, and heat transfer |
| Oil Return Line | Returns recovered oil to the lubrication circuit |
| Temperature Monitoring Device | Provides operating temperature information where fitted |
| Model / Product Family | Product Type | Typical Application |
|---|---|---|
| Ingersoll Rand 24509184 | Temperature Control Valve Service Kit | Repairing the compatible compressor temperature control valve |
| Ingersoll Rand 22832885 | Thermostatic Valve Kit | Related temperature-control maintenance reference |
| Ingersoll Rand 24900433 | Oil Filter | Filtration of circulating compressor lubricant |
| Ingersoll Rand 24900342 | Air Oil Separator | Separation of oil from compressed air |
| Ingersoll Rand 48958201 | Air Filter Element | Intake filtration in compatible compressor systems |
| Ingersoll Rand 49007941 | Pre-Filter Pad | Preliminary intake air filtration |
| Ingersoll Rand RS-Series | Rotary Screw Air Compressors | Industrial compressed-air generation |
The 24509184 kit is identified as a temperature control valve service kit. It is intended for maintenance of the valve that regulates lubricant flow according to operating temperature in compatible compressor systems.
A valve that sticks or fails to route lubricant correctly can interfere with temperature regulation. This may contribute to abnormal oil temperature behavior and affect the compressor’s thermal operating conditions.
Not necessarily. The kit is intended to service the applicable valve assembly. Whether the existing valve can be repaired depends on the condition of its housing, seating surfaces, and other serviceable components.
Inspect the valve installation and operation, oil cooler condition, lubricant level, and available temperature readings. Restricted oil passages or problems elsewhere in the cooling circuit can also contribute to abnormal temperature behavior.