• Ingersoll Rand 47572168001 99289894 Minimum Pressure Check Valve Repair Kit
  • Ingersoll Rand 47572168001 99289894 Minimum Pressure Check Valve Repair Kit
  • Ingersoll Rand 47572168001 99289894 Minimum Pressure Check Valve Repair Kit
  • Ingersoll Rand 47572168001 99289894 Minimum Pressure Check Valve Repair Kit
1. Product Overview The Ingersoll Rand 47572168001 / 99289894 Minimum Pressure Check Valve Repair Kit is an industrial compressor maintenance component intended for servicing a compatible minimum pressu……
Ingersoll Rand 47572168001 99289894 Minimum Pressure Check Valve Repair Kit
  • Ingersoll Rand
  • 47572168001 99289894
  • Minimum Pressure Check Valve Repair Kit
  • USA
  • 84 × 84 × 202 mm
  • 1.41 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

Ingersoll Rand 47572168001 99289894 Minimum Pressure Check Valve Repair Kit

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Ingersoll Rand 47572168001 99289894 Minimum Pressure Check Valve Repair Kit

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Ingersoll Rand 47572168001 99289894 Minimum Pressure Check Valve Repair Kit

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Ingersoll Rand 47572168001 99289894 Minimum Pressure Check Valve Repair Kit

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

1. Product Overview

The Ingersoll Rand 47572168001 / 99289894 Minimum Pressure Check Valve Repair Kit is an industrial compressor maintenance component intended for servicing a compatible minimum pressure check valve assembly. This type of valve plays an important role in many oil-injected screw compressor systems by helping maintain the required internal pressure and controlling compressed-air flow from the compressor.

A minimum pressure check valve typically combines minimum-pressure regulation with a non-return function. It helps the compressor establish an appropriate internal pressure during operation while allowing compressed air to flow toward the downstream system under the designed conditions. Its check-valve function also helps prevent downstream pressure from flowing backward into the compressor when operating conditions change.

Over time, internal valve components and sealing elements may wear, become contaminated, or lose their ability to operate correctly. These conditions can contribute to pressure instability, air leakage, abnormal loading behavior, or other compressor performance issues. A suitable repair kit allows maintenance personnel to service the valve using the specified replacement components instead of automatically replacing the complete valve assembly.

The Ingersoll Rand 47572168001 / 99289894 Minimum Pressure Check Valve Repair Kit has supplied dimensions of 84 × 84 × 202 mm and a listed weight of 1.41 kg. These specifications are useful for product identification, spare-parts planning, and inventory management. Before ordering or installing the kit, confirm its compatibility with the exact compressor model and valve assembly.

2. Technical Specifications

Parameter Specification
Brand Ingersoll Rand
Part Number 47572168001
Additional Part Number 99289894
Product Type Minimum Pressure Check Valve Repair Kit
Product Category Industrial Air Compressor Maintenance Parts
Dimensions 84 × 84 × 202 mm
Weight 1.41 kg
Primary Function Servicing a compatible minimum pressure check valve assembly
Application Industrial compressor maintenance, subject to model verification
Valve Function Minimum-pressure regulation and check-valve operation, depending on the installed design
Installation Method Follow the compressor-specific service instructions
Kit Contents Confirm the included components against the product documentation
Compatibility Verify the compressor model and original valve part number
Maintenance Requirements Inspect and service according to the manufacturer’s recommendations

Specification note: The part numbers, dimensions, and weight are provided as supplied. The exact compatible compressor models, included repair components, pressure settings, sealing materials, and valve performance limits should be verified against the applicable equipment documentation.

3. Function and Working Principle

A minimum pressure check valve is commonly used in oil-injected screw compressors to support internal pressure regulation and control the direction of compressed-air flow. Its exact construction and operating sequence depend on the compressor design.

The valve generally helps maintain a minimum pressure within the compressor’s internal system before allowing air to flow normally into the downstream compressed-air network. The required internal pressure can be important to the operation of the compressor’s oil circulation and separation processes.

The check-valve function helps limit reverse airflow from the downstream system when the compressor stops or when pressure conditions change. The minimum-pressure and non-return functions work together to support the intended operating behavior of the compressor.

3.1 Minimum Pressure Regulation

During startup and operation, the compressor may need to establish a specified internal pressure before supplying air to the downstream system. The minimum pressure valve helps regulate this transition according to its design.

Maintaining the intended internal pressure can support the operation of associated compressor systems, including oil circulation and air-oil separation in applicable oil-injected designs.

3.2 Non-Return Function

The check-valve mechanism helps prevent compressed air from flowing backward into the compressor when downstream pressure is higher than the pressure available at the valve inlet.

Reverse-flow control can help limit unwanted pressure changes when the compressor unloads or stops. The precise behavior depends on the valve configuration and the overall compressed-air system.

3.3 Relationship with Oil Separation

In many oil-injected screw compressors, the minimum pressure valve works alongside the air-oil separator and oil circulation system. Maintaining the intended internal pressure helps support the operating conditions required by these components.

A valve fault may therefore affect more than the outlet pressure alone. Troubleshooting should consider the compressor’s complete operating system and not just the valve body.

3.4 Purpose of the Repair Kit

A repair kit is intended to provide specified replacement components for servicing the relevant valve assembly. Depending on the kit design, these may include sealing elements or other internal service parts.

The exact contents of the Ingersoll Rand 99289894 kit should be checked before work begins. Do not assume that every internal valve component is included or that the kit is suitable for every minimum pressure valve.

4. Role in Industrial Compressor Systems

The minimum pressure check valve contributes to the operating stability of compatible compressor systems by helping regulate pressure and control airflow.

Internal Pressure Management

Maintaining the designed internal pressure helps the compressor operate within its intended conditions. The valve supports this function as part of the wider pressure and airflow arrangement.

Compressed-Air Delivery

The valve controls the transition between the compressor’s internal system and the downstream air network. Correct operation helps support the intended delivery of compressed air.

Reverse-Flow Prevention

The check-valve function helps limit reverse airflow when operating conditions change. This is particularly relevant during unloading, shutdown, or pressure changes in the downstream system.

Support for Oil Circulation and Separation

In applicable oil-injected compressor designs, internal pressure influences oil circulation and separation performance. A malfunctioning valve may contribute to related operating symptoms, although other faults can produce similar problems.

Maintenance and Equipment Reliability

Servicing a valve with the correct repair kit can help restore its intended function when the fault is associated with replaceable internal components. Correct diagnosis and installation are essential to avoid recurring problems.

5. Industrial Applications

The Ingersoll Rand 47572168001 / 99289894 Minimum Pressure Check Valve Repair Kit may be suitable for maintenance of compatible industrial compressors after the exact equipment application has been verified.

5.1 Manufacturing Facilities

Manufacturing plants often rely on compressed air for pneumatic tools, actuators, automated machinery, and material handling systems. Maintaining the compressor’s pressure-control components helps support a stable compressed-air supply.

5.2 Automotive and Assembly Operations

Automotive production and assembly facilities use compressed air for a variety of pneumatic operations. Proper maintenance of compatible compressor valves can help reduce interruptions caused by pressure-control faults.

5.3 Packaging Machinery

Packaging lines use compressed air for actuators, gripping systems, and repetitive machine operations. A properly functioning compressor pressure valve contributes to the intended operating conditions of the air supply system.

5.4 Process and General Industrial Equipment

Industrial processes may depend on compressed air for instrument systems, pneumatic mechanisms, and production equipment. Minimum pressure check valve maintenance can form part of the compressor’s broader preventive maintenance program.

5.5 Centralized Compressed-Air Systems

Large facilities may use multiple compressors connected to a shared air network. Correct valve operation helps each compatible compressor maintain its intended internal pressure and manage airflow to the distribution system.

These are general applications of compatible minimum pressure check valves. They do not confirm that this specific repair kit fits every Ingersoll Rand compressor or every application listed.

6. Installation and System Integration

Repairing a minimum pressure check valve requires careful attention to stored pressure, internal components, sealing, and the manufacturer’s service procedure. The following steps provide a general maintenance framework. The service manual for the exact compressor model takes precedence.

Step 1: Verify the Repair Kit

Confirm that the kit is identified as Ingersoll Rand 47572168001 / 99289894. Compare the part number with the compressor’s approved parts list and the identification information for the installed valve.

Check the kit contents before disassembly to ensure that the required service components are available.

Step 2: Shut Down and Isolate the Compressor

Stop the compressor using the approved shutdown procedure. Isolate the electrical supply and other relevant energy sources in accordance with the site’s lockout/tagout requirements.

Relieve stored pressure from the relevant sections of the system and verify that the equipment is safe to open. Never loosen a pressurized valve housing or connection.

Step 3: Allow the Equipment to Cool

Compressor components and lubricating oil may remain hot after shutdown. Allow the equipment to cool as required by the service instructions before handling the valve assembly.

Use suitable personal protective equipment and follow the site’s procedures for handling oil and other service materials.

Step 4: Identify the Valve Assembly

Locate the minimum pressure check valve using the compressor documentation. Confirm its position, connection arrangement, and relationship with the air-oil separator and downstream piping where applicable.

Record relevant operating symptoms and diagnostic information before removing components.

Step 5: Remove the Valve Assembly as Required

Follow the specified procedure for accessing and removing the valve or its serviceable components. Keep parts organized and note their orientation.

Avoid damaging the valve body, sealing surfaces, threaded connections, or adjacent components during disassembly.

Step 6: Inspect the Internal Components

Inspect the valve and its serviceable parts for contamination, wear, damaged sealing surfaces, deformation, or other defects identified in the service documentation.

Determine whether the valve body remains suitable for repair. A repair kit may not address damage to the main housing or other non-included components.

Step 7: Install the Repair Components

Replace the specified internal components according to the approved service procedure. Ensure that seals and other parts are positioned correctly and that the assembly is free from contamination.

Use only the specified lubricants, sealants, and fastening methods. Do not estimate torque values, alter parts, or change the valve’s pressure setting without authorization.

Step 8: Reassemble the Valve

Reassemble the valve in the prescribed order. Check that all components move or seat as intended according to the manufacturer’s inspection procedure.

Verify that connections and sealing surfaces are clean and that the completed assembly is suitable for reinstallation.

Step 9: Reinstall and Inspect the Assembly

Install the repaired valve according to the equipment documentation. Confirm that connections are secure and that the valve is correctly oriented.

Check the surrounding piping and associated components for visible damage or conditions that may have contributed to the original fault.

Step 10: Restore Operation and Verify Performance

Restore power and return the compressor to service according to the approved commissioning procedure. Observe startup, pressure development, loading and unloading behavior, and available diagnostic indications as applicable.

Check for leakage and abnormal operation. Verify that the compressor operates within its specified pressure and performance limits before returning it to routine service.

7. Common Problems and Troubleshooting

A faulty minimum pressure check valve may produce symptoms that overlap with problems in other compressor components. Troubleshooting should consider the valve, pressure-control arrangement, oil circulation system, and downstream air network.

Symptom Possible Causes Recommended Checks
Internal pressure develops too slowly Valve malfunction, leakage, or another compressor operating fault Review pressure behavior and inspect the valve according to the service procedure
Compressor outlet pressure is lower than expected Valve restriction, system leakage, excessive demand, or another fault Check operating conditions, valve behavior, and downstream demand
Abnormal pressure changes during startup Valve sticking, damaged sealing components, or control-related issues Review startup behavior and inspect the valve assembly
Reverse airflow or pressure loss after shutdown Check-valve malfunction or a downstream system issue Follow the prescribed non-return valve test and inspect related components
Increased oil carryover Internal pressure problem, separator issue, oil return restriction, or another fault Check the valve, separator, oil return arrangement, and operating conditions
Air leakage around the valve Damaged seal, loose connection, or incorrect assembly Isolate and depressurize the equipment before inspection
Problem persists after repair Incorrect kit, installation error, damaged valve body, or unrelated fault Verify compatibility, repair quality, valve condition, and system diagnostics

7.1 Check Internal Pressure Behavior

Review the compressor’s operating pressure and startup sequence against the specified values for the installed model. A pressure-related symptom does not automatically establish that the minimum pressure valve is defective.

7.2 Inspect Seals and Moving Components

If the service procedure identifies worn seals or sticking components, inspect them for contamination, damage, and incorrect installation. Replace only the parts specified for the approved repair.

7.3 Verify the Check-Valve Function

Use the manufacturer’s prescribed test to determine whether the valve is controlling reverse flow correctly. Avoid improvised tests that may expose personnel to stored pressure or damage the equipment.

7.4 Review Related Compressor Systems

The minimum pressure valve may operate alongside the air-oil separator, oil return path, pressure sensors, and control system. Inspect related components when symptoms suggest a wider system problem.

7.5 Confirm the Repair Kit and Assembly

If the fault remains after servicing, verify the kit part number, included components, assembly sequence, sealing arrangement, and valve-body condition. Do not repeatedly replace the same parts without identifying the underlying cause.

8. Preventive Maintenance and Reliability

A structured maintenance program helps maintain valve performance and reduce avoidable compressor interruptions.

  • Monitor operating pressure: Record abnormal pressure behavior and investigate changes from normal operating conditions.
  • Follow the service schedule: Inspect and repair the valve according to the manufacturer’s recommendations.
  • Keep components clean: Prevent dust, debris, and other contaminants from entering the valve during maintenance.
  • Inspect sealing components: Check serviceable seals for wear or damage when required by the maintenance procedure.
  • Review oil and separator performance: In oil-injected systems, consider related oil circulation and separation conditions when investigating valve faults.
  • Use approved repair kits: Confirm the complete part number and kit contents before beginning work.
  • Maintain service records: Document repair dates, replaced parts, diagnostic findings, and operating checks.
  • Check for recurring symptoms: Investigate repeated pressure instability or leakage instead of treating each occurrence as an isolated problem.
  • Observe safe isolation procedures: Isolate energy sources and fully relieve relevant stored pressure before servicing the valve.

Maintenance intervals should be based on the specific compressor design, operating conditions, duty cycle, and manufacturer recommendations.

9. Compatible System Components

The following table identifies component categories that may need to be checked during valve servicing. It does not confirm compatibility with specific part numbers.

Component Category Integration Considerations
Compressor assembly Confirm the exact model and approved valve configuration
Minimum pressure check valve Verify the original valve part number and repair requirements
Air-oil separator Check the related system arrangement and operating condition where applicable
Oil return components Inspect the return path if oil-related symptoms are present
Seals and gaskets Confirm the correct type, material, and replacement requirements
Pressure monitoring devices Review available pressure readings and diagnostic indications
Downstream compressed-air piping Check for leaks, reverse-flow symptoms, and abnormal demand
Control system Review relevant startup, loading, unloading, and alarm behavior
Service documentation Use the correct parts list and maintenance instructions for the compressor

Compatibility must be confirmed using the exact compressor model and its approved technical documentation. Similar valve descriptions or dimensions do not establish interchangeability.

10. Replacement and Alternative Selection

When selecting a replacement for the Ingersoll Rand 47572168001 / 99289894 Minimum Pressure Check Valve Repair Kit, technicians should confirm both the repair kit’s contents and its suitability for the installed valve.

Selection Factor What to Verify
Part number Confirm 47572168001 and 99289894 against the approved parts list
Compressor model Verify compatibility with the exact equipment configuration
Valve identification Confirm the original valve model or part number
Kit contents Check which internal components and seals are included
Pressure requirements Verify the valve’s specified operating requirements and settings
Mechanical compatibility Confirm the relevant dimensions, sealing arrangement, and assembly configuration
Material requirements Ensure replacement components meet the specified service conditions
Product condition Check packaging, storage condition, and component integrity
Installation requirements Identify required tools, service procedures, and commissioning checks
Documentation Confirm part identification and traceability information

A repair kit should not be selected based only on its dimensions or general product description. Differences in internal construction, seals, and valve configuration may make a similar-looking kit unsuitable.

If the original kit is unavailable, use an alternative only after its technical equivalence has been established for the specific valve assembly.

11. Key Benefits of Correct Repair Kit Selection

Selecting the correct minimum pressure check valve repair kit can support effective compressor maintenance.

Supports Valve Servicing

A compatible kit provides the specified replacement components for the intended repair, provided the valve is suitable for servicing and the kit contents meet the repair requirements.

Helps Restore Pressure Regulation

When worn or damaged serviceable components are responsible for a pressure-control problem, correct repair may help restore the valve’s intended operation.

Supports Reverse-Flow Control

Properly servicing the check-valve mechanism can help maintain its intended non-return function, subject to the valve design and condition.

Helps Maintain Compressor Performance

Correct valve operation supports the designed relationship between internal pressure and compressed-air delivery in compatible compressor systems.

Supports Spare-Parts Management

The supplied part numbers, dimensions, and weight provide useful information for inventory identification and maintenance planning.

Encourages Systematic Troubleshooting

Using the approved kit and service procedure helps maintenance personnel distinguish between valve-related faults and problems originating elsewhere in the compressor system.

These benefits depend on correct diagnosis, verified compatibility, proper installation, and adherence to the equipment manufacturer’s requirements.

12. Technical FAQs

Q1: What is the Ingersoll Rand 47572168001 / 99289894?

It is identified in the supplied product information as a Minimum Pressure Check Valve Repair Kit for a compatible industrial compressor application. The exact supported compressor models and valve configurations should be confirmed from the approved parts documentation.

Q2: What are the dimensions of the repair kit?

The supplied dimensions are 84 × 84 × 202 mm.

Q3: How much does the repair kit weigh?

The supplied product weight is 1.41 kg.

Q4: What does a minimum pressure check valve do?

In many oil-injected screw compressors, it helps maintain the required internal pressure and controls the direction of compressed-air flow. The exact operating characteristics depend on the compressor and valve design.

Q5: What is the purpose of a repair kit?

A repair kit provides specified replacement components for servicing a compatible valve assembly. Its exact contents should be checked before the repair begins.

Q6: What symptoms may indicate a faulty minimum pressure check valve?

Possible symptoms include abnormal pressure development, pressure instability, reverse-flow problems, or oil carryover in applicable systems. These symptoms may also have other causes and require systematic diagnosis.

Q7: Can this repair kit be used with any Ingersoll Rand compressor?

No. Compatibility depends on the exact compressor model, installed valve configuration, and approved parts requirements. Confirm the part number before ordering.

Q8: Does replacing the repair components always solve pressure problems?

No. The valve body may be damaged, the kit may be unsuitable, or the underlying fault may originate in another compressor component or control function.

Q9: Can the valve’s minimum pressure setting be adjusted during repair?

Only when the equipment documentation authorizes the adjustment and specifies the correct procedure. Do not change pressure settings based on assumptions or generic values.

Q10: What should be checked after repairing the valve?

Verify correct assembly, sealing, pressure behavior, reverse-flow function where specified, and overall compressor operation. Complete the prescribed post-maintenance checks before returning the equipment to normal service.

13. Conclusion

The Ingersoll Rand 47572168001 / 99289894 Minimum Pressure Check Valve Repair Kit is an industrial compressor maintenance component intended for servicing a compatible minimum pressure check valve assembly. Its supplied dimensions of 84 × 84 × 202 mm and weight of 1.41 kg provide useful information for product identification and spare-parts management.

Before purchasing or installing the kit, confirm the exact compressor model, valve configuration, and included replacement components. Safe pressure isolation, careful inspection, correct assembly, and post-repair testing are essential to reliable maintenance. By following the equipment-specific service instructions and investigating the underlying cause of valve problems, maintenance teams can help preserve compressor performance and reduce avoidable downtime.