• GE SR489-CASE SR489-P1-HI-A20-E Generator Management Relay
  • GE SR489-CASE SR489-P1-HI-A20-E Generator Management Relay
  • GE SR489-CASE SR489-P1-HI-A20-E Generator Management Relay
  • GE SR489-CASE SR489-P1-HI-A20-E Generator Management Relay
Product Overview The GE SR489-CASE 489-P1-HI-A20-E Generator Management Relay is a configured version of the GE Multilin 489 protection platform for small and medium-sized synchronous or induction gener……
GE SR489-CASE SR489-P1-HI-A20-E Generator Management Relay
  • GE
  • SR489-CASE 489-P1-HI-A20-E
  • Generator Management Relay
  • USA
  • 252 × 216 × 224 mm
  • 7.7 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

GE SR489-CASE SR489-P1-HI-A20-E Generator Management Relay

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE SR489-CASE SR489-P1-HI-A20-E Generator Management Relay

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE SR489-CASE SR489-P1-HI-A20-E Generator Management Relay

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE SR489-CASE SR489-P1-HI-A20-E Generator Management Relay

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE SR489-CASE 489-P1-HI-A20-E Generator Management Relay is a configured version of the GE Multilin 489 protection platform for small and medium-sized synchronous or induction generators. It combines electrical protection, generator metering, temperature monitoring and fault diagnostics in a drawout relay assembly used in generator switchgear and control panels.

The P1 configuration accepts 1 A phase current-transformer secondary signals, making CT selection and ratio configuration important during commissioning. The HI power option supports high-range AC or DC auxiliary supplies, while A20 specifies 4–20 mA analog outputs for transmitting selected measurements to compatible external equipment. The E option adds an enhanced display with a larger LCD and improved keypad.

In a generator protection scheme, the relay evaluates electrical measurements and connected monitoring signals against configured settings. It can initiate assigned trip or alarm responses when enabled protection elements detect qualifying conditions. Event records, waveform capture and metering data also help engineers examine disturbances and investigate generator trips.


Technical Specifications

Parameter Specification
Manufacturer GE
Model / Order Number SR489-CASE 489-P1-HI-A20-E
Product Family GE Multilin 489
Product Type Generator Management Relay
Phase CT Input Option P1
Phase CT Secondary Rating 1 A
Control Power Option HI
DC Control Power Input 90–300 V DC
AC Control Power Input 70–265 V AC
AC Control Power Frequency 48–62 Hz
Analog Output Option A20
Analog Output Range 4–20 mA
Display Option E — Enhanced display with larger LCD and improved keypad
Digital Inputs 9 opto-isolated inputs
RTD Monitoring Supports up to 12 RTD inputs
Analog Transducer Inputs Supports configured current-input signals for monitoring applications
Communication Interfaces Front-panel RS232 and RS485 serial interfaces
Communication Protocols Modbus RTU, DNP 3.0
Protection Functions Configurable generator electrical, differential, ground-fault and thermal protection
Construction Drawout relay and fixed case
Dimensions 252 × 216 × 224 mm
Weight 7.7 kg

Product Features

  • 1 A phase CT inputs: Accommodates generator installations using 1 A phase current-transformer secondary circuits.
  • High-range auxiliary power: Accepts the specified high-range AC or DC supply, allowing the configuration to match compatible control-power systems.
  • 4–20 mA analog outputs: Sends selected measurements to external meters, recorders or control-system analog inputs.
  • Enhanced display and keypad: Gives operators a larger local interface for reviewing measurements, relay messages and settings.
  • Generator-specific protection: Supports configurable protection functions for electrical faults and abnormal generator operating conditions.
  • Stator and bearing temperature monitoring: Uses connected RTD sensors for configured thermal monitoring.
  • Additional transducer monitoring: Supports external analog transducer signals for applications such as vibration monitoring when configured appropriately.
  • Event and waveform records: Provides diagnostic information for analyzing electrical disturbances and protection operations.
  • Serial communication: Supports integration with compatible engineering and supervisory systems.
  • Drawout construction: Allows the relay unit to be withdrawn from its case for inspection or replacement under the prescribed isolation procedure.

Working Principle

The 489 receives generator current and voltage measurements from connected instrument transformers. The relay processes these inputs and evaluates them against programmed generator ratings, protection thresholds and timing settings. With the P1 option, the phase CT secondary circuits must be rated at 1 A, and the configured ratios must match the installed transformers.

Enabled protection elements monitor the measured conditions for faults such as abnormal current, ground faults, loss of excitation and other generator-related electrical problems. Depending on the application and enabled functions, the relay can operate an assigned trip or alarm output when its pickup and timing criteria are met. RTD inputs provide additional information for configured stator and bearing thermal protection.

The A20 option supplies 4–20 mA analog outputs for selected supported measurements. These signals can be used by compatible external monitoring equipment, provided the receiving input range and scaling are configured correctly. The enhanced display provides local access to operating information, while event and waveform records support post-event analysis.

Correct CT and VT ratios, generator settings, trip assignments and auxiliary power connections are essential to the protection scheme. Commissioning should verify the measurement circuits and the complete trip path rather than testing the relay in isolation.


Role in a Generator Protection and Control Architecture

The GE Multilin 489 serves as a local protection and monitoring device between generator instrumentation, breaker-control circuits and plant supervision equipment. It evaluates connected measurements and issues configured trip or alarm commands while supplying operating information for local and remote analysis.

System Component Function Relationship to the Relay
1 A Phase Current Transformers Measure generator phase currents Provide current signals matching the P1 input configuration
Voltage Transformers Supply generator voltage measurements Provide signals used by enabled voltage, frequency and power-related functions
RTD Temperature Sensors Measure stator and bearing temperatures Supply data for configured thermal protection and monitoring
Analog Transducers Measure selected physical operating conditions Supply supported analog signals for monitoring applications
Generator Circuit Breaker Connects or isolates the generator Receives a trip command through the assigned control circuit
Breaker Auxiliary Contacts Report breaker position and status Supply external status signals to configured digital inputs
4–20 mA Receiving Equipment Displays or records selected measurements Receives signals from the A20 analog outputs
Plant PLC or SCADA System Supervises generator operation Uses supported communication data or analog measurements
Auxiliary Control Power Supply Powers the relay electronics Must meet the HI option’s voltage and frequency requirements

Industrial Applications

Application Protection or Monitoring Requirement Role of the Relay
Industrial Generator Sets Detect abnormal electrical operating conditions Evaluates enabled protection elements and operates assigned outputs
Combined Heat and Power Plants Coordinate generator protection with plant electrical operation Provides generator measurements, protection responses and diagnostic records
Standby Power Installations Monitor generator condition during backup operation Supports configured protection and alarm functions
Industrial Power Stations Investigate disturbances affecting generator operation Supplies event, waveform and measurement information
Generator Switchgear Integrate instrument-transformer signals with breaker control Acts as the local protection and monitoring layer
Generator Condition Monitoring Combine electrical measurements with temperature or transducer inputs Supports configured monitoring functions using connected sensors

Installation and Maintenance

  1. Verify the full order code: Confirm that SR489-CASE 489-P1-HI-A20-E matches the required CT input, auxiliary power, analog output and display configuration.
  2. Inspect the relay case: Check the case identification, terminal condition, connectors and drawout mechanism before installation.
  3. Confirm auxiliary power: Verify that the available supply is within 90–300 V DC or 70–265 V AC at 48–62 Hz.
  4. Check the phase CT circuits: Confirm that the phase CT secondary rating is 1 A and that the programmed ratios match the installed transformers.
  5. Verify CT polarity and phase assignment: Compare the connections with the generator protection drawings to prevent incorrect measurements and unintended protection responses.
  6. Validate voltage input configuration: Check VT wiring, phase relationships and programmed ratios for functions that depend on voltage measurements.
  7. Inspect RTD and transducer wiring: Confirm the sensor types, terminal assignments and input configuration for each enabled monitoring function.
  8. Test analog output loops: Verify that the receiving equipment accepts 4–20 mA signals and that output assignments and scaling match the intended measurements.
  9. Review generator protection settings: Check generator ratings, enabled protection elements, pickup thresholds, time delays and output assignments against the approved protection scheme.
  10. Verify breaker trip interfaces: Test the assigned output relay and downstream trip circuit using an approved commissioning procedure.
  11. Check communication and display operation: Verify the enhanced display, keypad and required serial communication interfaces.
  12. Record commissioning results: Document the order code, CT and VT ratios, power-supply range, protection settings, analog-output assignments and functional test results.

Compatible System Components

Component Function Compatibility Consideration
1 A Phase Current Transformers Supply generator phase-current measurements Match the P1 input rating and configured CT ratios
Generator Voltage Transformers Provide voltage measurements Verify secondary ratings, wiring arrangement and programmed ratios
RTD Temperature Sensors Measure stator and bearing temperatures Confirm supported sensor types and correct input wiring
Analog Monitoring Transducers Provide signals for selected physical measurements Verify output signal type and compatibility with the relay’s configured inputs
Generator Circuit Breaker Trip Circuit Disconnects the generator following a trip command Check output assignment, trip-coil requirements and control-circuit design
Breaker Auxiliary Contacts Report breaker position Confirm input assignments and expected contact states
4–20 mA Analog Input Receives selected relay measurements Match the signal range and scaling to the A20 output configuration
RS485 Serial Network Carries supported communication data Configure compatible protocol, addressing and serial settings
Plant PLC or SCADA System Displays generator status and measurements Validate supported data mapping and communication configuration

Recommended Related Models

Model Product Type Relationship Selection Consideration
GE 489-P5-HI-A20-E Generator Management Relay Related configuration with 5 A phase CT inputs, HI power, A20 outputs and enhanced display Consider when the installed phase CT secondary circuits are rated at 5 A
GE 489-P1-LO-A20-E Generator Management Relay Related configuration with 1 A phase CT inputs and low-range control power Compare the LO input range with the available auxiliary supply
GE 489-P1-HI-A1-E Generator Management Relay Related configuration with 1 A phase CT inputs and 0–1 mA analog outputs Consider when the receiving equipment requires the A1 output range
GE 489-P1-HI-A20-T Generator Management Relay Related configuration with 1 A CT inputs, HI power, A20 outputs and an enhanced display with Ethernet Consider when Ethernet connectivity is required and verify the full order code

Key Advantages

  • Matches generator protection systems using 1 A phase CT secondary circuits.
  • Accepts high-range AC or DC auxiliary power.
  • Provides 4–20 mA analog outputs for external monitoring.
  • Combines generator protection, metering, temperature monitoring and diagnostics.
  • Supports event and waveform review for investigating generator disturbances.
  • Offers an enhanced local interface for reviewing measurements and relay information.

Technical FAQs

How can the P1 configuration affect generator current measurements?

The P1 option is intended for 1 A phase CT secondary circuits. The installed CT ratio, polarity and phase assignment must match the relay configuration so that current measurements and protection calculations reflect actual generator conditions.

When can waveform records be useful during generator fault analysis?

Waveform records can help engineers examine electrical signals around a disturbance and correlate them with event records and protection operations. Their usefulness depends on the captured event, the available records and the configured recording settings.

How should the A20 analog outputs be checked during commissioning?

Confirm that the receiving equipment accepts 4–20 mA signals, assign supported measurements to the intended channels, and verify scaling across the expected operating range. Compare remote readings with relay measurements before putting the monitoring loop into service.

What should be reviewed if a generator protection trip cannot be explained by the displayed measurements?

Review the event sequence, available waveform records, enabled protection elements, configured thresholds and timing settings. Also verify CT and VT wiring, instrument-transformer ratios and breaker-status inputs before changing protection settings.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501