• GE SR489-CASE SR489-P1-LO-A20 Generator Management Relay
  • GE SR489-CASE SR489-P1-LO-A20 Generator Management Relay
  • GE SR489-CASE SR489-P1-LO-A20 Generator Management Relay
  • GE SR489-CASE SR489-P1-LO-A20 Generator Management Relay
Product Overview The GE SR489-CASE SR489-P1-LO-A20 Generator Management Relay is a GE Multilin 489 generator protection relay configuration for synchronous and induction generator systems. It combines g……
GE SR489-CASE SR489-P1-LO-A20 Generator Management Relay
  • GE
  • SR489-CASE SR489-P1-LO-A20
  • Generator Management Relay
  • USA
  • 252 × 216 × 224 mm
  • 7.7 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

GE SR489-CASE SR489-P1-LO-A20 Generator Management Relay

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE SR489-CASE SR489-P1-LO-A20 Generator Management Relay

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE SR489-CASE SR489-P1-LO-A20 Generator Management Relay

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE SR489-CASE SR489-P1-LO-A20 Generator Management Relay

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE SR489-CASE SR489-P1-LO-A20 Generator Management Relay is a GE Multilin 489 generator protection relay configuration for synchronous and induction generator systems. It combines generator electrical measurements, programmable protection functions, thermal monitoring, trip logic and event recording within a drawout relay platform.

The P1 option specifies 1 A phase current transformer inputs, making this configuration suitable for installations whose phase CT secondary circuits are rated at 1 A. The LO power option supports a low-range auxiliary supply, while A20 specifies 4–20 mA analog outputs for transmitting selected measurements to compatible monitoring equipment. These options must be matched to the generator’s instrument transformers, panel supply and control-system requirements.

The relay evaluates current, voltage, frequency and configured condition-monitoring inputs against programmed settings. Depending on the protection elements enabled, it can initiate assigned trips and alarms for abnormal generator operating conditions. Serial communication and recorded event information support operational supervision, fault investigation and maintenance.


Technical Specifications

Parameter Specification
Manufacturer GE
Model / Order Number SR489-CASE SR489-P1-LO-A20
Product Family GE Multilin 489
Product Type Generator Management Relay
Phase CT Input Option P1
Phase CT Secondary Rating 1 A
Control Power Option LO
DC Control Power Input 20–60 V DC
AC Control Power Input 20–48 V AC
AC Control Power Frequency 48–62 Hz
Analog Output Option A20
Analog Output Range 4–20 mA
Display Configuration Basic display configuration
Digital Inputs 9 opto-isolated inputs
RTD Inputs Supports connected RTD temperature sensors
Communication Interfaces RS232 and RS485
Communication Protocols Modbus RTU, DNP 3.0
Output Relays 6 electromechanical Form-C relays
Protection Functions Configurable generator electrical and thermal protection
Mounting Format Drawout relay
Dimensions 252 × 216 × 224 mm
Weight 7.7 kg

Product Features

  • 1 A phase CT inputs: Matches generator installations using current transformers with 1 A secondary outputs, with correct CT ratios entered into the relay settings.
  • Low-range auxiliary power: Supports DC and AC control supplies within the specified LO input range.
  • 4–20 mA analog outputs: Allows selected supported measurements to be transmitted to compatible meters, controllers or monitoring equipment.
  • Generator protection functions: Supports configurable protection for electrical abnormalities and operating conditions.
  • RTD-based temperature monitoring: Uses connected temperature sensors for configured stator, bearing or other supported thermal monitoring points.
  • Programmable trip and alarm logic: Associates enabled protection elements with assigned output contacts and alarm responses.
  • Serial communications: Provides RS232 and RS485 interfaces for supported data exchange and engineering access.
  • Event and diagnostic records: Helps maintenance personnel review recorded conditions and investigate generator trips.
  • Drawout construction: Allows the relay unit to be removed from its case for inspection or replacement following the prescribed isolation procedure.

Working Principle

The SR489-P1-LO-A20 receives generator current signals from connected current transformers and voltage signals from voltage transformers. The relay converts these inputs into electrical measurements and evaluates them against the configured generator ratings, protection thresholds and timing characteristics.

The P1 input configuration is intended for 1 A phase CT secondaries. Correct CT ratio, phase identification and polarity are essential because incorrect measurement scaling can affect metering and protection decisions. Voltage-transformer ratios and connection settings must likewise match the actual generator measurement circuits.

When an enabled protection element detects a condition that satisfies its configured operating criteria, the relay can activate the assigned trip or alarm output. RTD inputs and other configured signals can contribute additional information for thermal and condition monitoring.

The A20 option supplies 4–20 mA analog outputs. Configured output channels can transmit supported measurements to external equipment for display, recording or supervisory monitoring. The relay’s communications and event records provide additional information for reviewing operating conditions and diagnosing protection operations.


Role in a Generator Protection and Control Architecture

The GE Multilin 489 functions as the local protection and monitoring layer between generator instrument transformers, temperature sensors, breaker-control circuits and the plant supervisory system. It processes measurements within the relay and operates assigned outputs according to the configured protection logic.

System Component Function Relationship to the Relay
1 A Phase Current Transformers Supply scaled generator phase-current signals Match the P1 phase-input configuration
Voltage Transformers Supply generator voltage measurements Provide inputs for configured voltage, frequency and power-related functions
RTD Temperature Sensors Measure generator or bearing temperatures Supply thermal data for enabled monitoring and protection functions
Generator Circuit Breaker Connects or isolates the generator Receives trip commands through the assigned breaker-control circuit
Breaker Auxiliary Contacts Report breaker position or status Provide status information through configured input circuits
4–20 mA Receiving Equipment Displays or records analog measurements Receives configured outputs from the A20 option
Plant PLC or SCADA System Supervises plant operating conditions Exchanges supported status and measurement data
Auxiliary Power Supply Powers the relay electronics Must remain within the LO option’s specified input range

Industrial Applications

Application Operating Requirement Role of the Relay
Industrial Generator Sets Monitor generator electrical conditions and respond to faults Evaluates configured protection elements and operates assigned trip or alarm outputs
Standby Power Generation Supervise generator operation during backup service Provides local protection, measurements and event information
Combined Heat and Power Plants Coordinate generator protection with plant operation Supplies generator measurements and configured protection responses
Industrial Cogeneration Systems Monitor electrical and thermal operating conditions Combines electrical protection with supported temperature monitoring
Small and Medium Generator Installations Integrate protection into a dedicated generator panel Connects CT and VT measurements with breaker-control and monitoring circuits
Generator Retrofit Projects Match replacement protection equipment to existing instrumentation Requires verification of the 1 A CT input, low-range power and analog-output configuration

Installation and Maintenance

  1. Verify the complete order code: Confirm that SR489-CASE SR489-P1-LO-A20 matches the required 1 A CT input, LO control power and A20 analog-output options.
  2. Inspect the relay case: Check the case identification, terminal condition, mounting arrangement and relay insertion mechanism before installation.
  3. Confirm auxiliary power: Verify that the available supply falls within 20–60 V DC or 20–48 V AC at 48–62 Hz.
  4. Check phase CT secondary ratings: Confirm that the connected phase current transformers have 1 A secondary outputs and that their ratios match the programmed settings.
  5. Verify CT polarity and phase assignment: Check the wiring against the generator protection drawings to prevent incorrect current measurements or protection behavior.
  6. Validate voltage input wiring: Confirm voltage-transformer ratios, phase sequence and connection configuration before enabling protection functions that use voltage measurements.
  7. Inspect digital input circuits: Check external contacts, breaker-status signals and other configured inputs for correct wiring and expected operating states.
  8. Test the analog output circuits: Confirm that the receiving equipment accepts 4–20 mA signals and that channel assignments and scaling match the intended measurements.
  9. Check temperature sensor wiring: Verify RTD types, lead connections and input assignments for each enabled thermal monitoring function.
  10. Review protection settings: Check generator ratings, CT and VT ratios, pickup thresholds, time delays and output assignments against the approved protection study.
  11. Perform functional commissioning tests: Verify measurement scaling, configured alarms, trip logic, breaker interfaces and communication functions using an approved test procedure.
  12. Record the final configuration: Document the relay settings, input ratios, auxiliary supply, analog-output assignments and commissioning results for future maintenance.

Compatible System Components

Component Function Compatibility Consideration
1 A Phase Current Transformers Supply phase-current measurements Match the P1 input rating and programmed CT ratios
Generator Voltage Transformers Supply voltage measurements Confirm the secondary rating, wiring arrangement and programmed ratio
RTD Temperature Sensors Provide thermal measurements Use sensor types and wiring supported by the configured relay inputs
Generator Circuit Breaker Trip Circuit Opens the breaker when a configured trip operates Verify trip-coil ratings, auxiliary relays and control-circuit requirements
4–20 mA Analog Input Module Receives the relay’s analog output signals Confirm input range, scaling and loop wiring
RS485 Serial Network Carries supported communication data Verify wiring, addressing, protocol and serial settings
Engineering Computer Supports relay configuration and diagnostics Use compatible setup software and the appropriate communication interface
Plant PLC or SCADA System Supervises generator status and measurements Map supported data points and verify communication configuration

Recommended Related Models

Model Product Type Relationship Selection Consideration
GE SR489-P5-LO-A20 Generator Management Relay Related configuration with 5 A phase CT inputs, low-range power and 4–20 mA outputs Consider when the connected phase CT secondary rating is 5 A rather than 1 A
GE SR489-P1-HI-A20 Generator Management Relay Related configuration with 1 A phase CT inputs and high-range control power Consider when the panel auxiliary supply requires the HI range
GE SR489-P1-LO-A1 Generator Management Relay Related configuration with 1 A phase CT inputs and 0–1 mA analog outputs Consider when the receiving equipment requires a 0–1 mA signal
GE SR489-P1-LO-A20-E Generator Management Relay Related configuration with 1 A phase CT inputs, low-range power and 4–20 mA outputs, plus the enhanced-display option Compare the display and keypad requirements before selecting the version

Key Advantages

  • Matches generator systems using 1 A phase CT secondary circuits.
  • Supports low-range AC or DC auxiliary power.
  • Provides 4–20 mA analog outputs for compatible monitoring equipment.
  • Combines configurable generator protection, metering and thermal monitoring.
  • Supports trip and alarm assignments for integration with generator breaker-control circuits.
  • Provides serial communication and event information to support maintenance and fault investigation.

Technical FAQs

How should the P1 current input be matched to an existing generator protection circuit?

The P1 option is intended for 1 A phase CT secondaries. Before installation, verify the CT secondary rating, ratio, polarity and phase wiring, then enter the corresponding ratios in the relay configuration. A 5 A CT circuit should not be connected as though it were a 1 A input.

What should be considered when using the A20 outputs for remote generator monitoring?

Confirm that the receiving device accepts 4–20 mA signals and that the selected relay measurements are assigned to the intended channels. During commissioning, check signal scaling and the complete loop wiring so that the remote reading corresponds to the relay’s measured value.

Which auxiliary supply conditions are appropriate for the LO configuration?

The LO option accepts 20–60 V DC or 20–48 V AC at 48–62 Hz. Check the actual supply under operating conditions and ensure the polarity and wiring follow the relay installation requirements before energizing it.

What information is useful when investigating a generator trip after a disturbance?

Review the relay’s recorded events, measured values and the protection element that operated. Compare the event sequence with the configured pickup levels, time delays, CT/VT ratios and breaker status signals to help distinguish a genuine generator fault from a measurement or configuration problem.



Related Products