• Emerson VE5011 DeltaV Bulk Power Supply
  • Emerson VE5011 DeltaV Bulk Power Supply
  • Emerson VE5011 DeltaV Bulk Power Supply
  • Emerson VE5011 DeltaV Bulk Power Supply
Product Overview The Emerson VE5011 is a DeltaV bulk power supply used to convert incoming electrical power into a regulated DC supply for compatible control-system equipment. In a process-control cabin……
Emerson VE5011 DeltaV Bulk Power Supply
  • Emerson
  • VE5011
  • Bulk Power Supply
  • USA
  • 123 × 50 × 110 mm
  • 0.6 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

Emerson VE5011 DeltaV Bulk Power Supply

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Emerson VE5011 DeltaV Bulk Power Supply

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Emerson VE5011 DeltaV Bulk Power Supply

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Emerson VE5011 DeltaV Bulk Power Supply

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Emerson VE5011 is a DeltaV bulk power supply used to convert incoming electrical power into a regulated DC supply for compatible control-system equipment. In a process-control cabinet, it can support the power distribution arrangement for automation hardware, helping supply the DC power required by connected equipment.

Unlike an I/O module, the VE5011 does not acquire field signals or execute control logic. Its function is electrical power conversion and supply. This makes it relevant when building a DeltaV control cabinet, replacing a power supply in an existing installation, or checking whether the available DC supply can meet the connected equipment’s load requirements.

The VE5011’s compact form factor is useful where cabinet space is limited. Installation planning should still allow sufficient clearance for heat dissipation and wiring access. The input supply, DC output requirements, protective devices, and connected load must be evaluated together to ensure the power arrangement matches the intended application.


Technical Specifications

Parameter Specification
Brand Emerson
Model VE5011
Product Type Bulk Power Supply
Product Series DeltaV
Power Supply Category AC-to-DC power supply
Rated Output Voltage 24 V DC
Rated Output Current 5 A
Rated Output Power 120 W
Input Supply AC input
Input Protection Internal fuse protection
Output Function Supplies regulated DC power to compatible equipment
Mounting DIN rail
Protection Rating IP20
Dimensions 123 × 50 × 110 mm
Weight 0.6 kg

Product Features

24 V DC output: The power supply provides a 24 V DC output for compatible control-system loads. The total connected load should remain within the rated output capacity.

5 A output rating: The current rating helps determine whether the supply can support the intended equipment. Load calculations should include the normal operating current and any startup or transient demand.

Compact DIN-rail installation: The form factor supports installation in a control cabinet alongside other power and automation hardware. Adequate clearance should be maintained around the unit for ventilation and wiring access.

Internal input protection: Internal fuse protection helps address certain internal fault conditions. It should not be treated as a replacement for correctly selected upstream circuit protection.

Control-system power distribution: The VE5011 supplies electrical power rather than processing I/O signals. It should be evaluated as part of the cabinet’s complete power-distribution arrangement.

IP20 protection: The supply is intended for suitable protected installations. It does not provide protection against water ingress, so the cabinet environment must be appropriate for the unit.


Working Principle

The VE5011 converts incoming AC power into a regulated 24 V DC output. The connected control-system equipment draws current from this output according to its operating requirements. The supply must be selected and installed so that the combined load remains within its electrical ratings.

For example, a DeltaV control cabinet may contain control-system hardware and associated equipment that require 24 V DC power. The VE5011 can form part of the cabinet’s power arrangement, while separate controllers and I/O modules handle control execution and field-signal processing. The power supply’s output capacity must be assessed against the actual connected load rather than the number of devices alone.

During commissioning, technicians should verify the incoming supply, output voltage, wiring polarity, protective devices, and load distribution. If equipment resets or loses power intermittently, checking the DC supply and its connections is an important troubleshooting step alongside examining the connected devices.


Role in a DeltaV Control System Power Architecture

The VE5011 supports the electrical power layer of a DeltaV installation. It supplies DC power to compatible equipment, while controllers execute control strategies and I/O modules interface with field instruments. Correct power distribution helps prevent supply-related faults from affecting the wider control system.

System Component Function Relationship to VE5011
AC Input Supply Provides incoming electrical power Feeds the VE5011 input
VE5011 Bulk Power Supply Converts AC power to DC power Supplies the rated 24 V DC output
DC Distribution Terminals Distribute DC power to connected loads Route the supply output to the intended equipment
DeltaV Controller Executes control strategies Uses power supplied through the system’s power arrangement
I/O Modules Interface with field signals Require a suitable power arrangement for the installed hardware
Field Instruments Measure process variables or receive control commands May use separate or shared DC distribution, depending on the system design
Circuit Protection Protects wiring and connected equipment Must be selected for the supply and connected load
Cabinet Grounding Provides the required grounding and bonding Supports safe installation according to the cabinet design

Industrial Applications

Application Power Requirement Use of VE5011
Process-Control Cabinets Regulated DC power for compatible control equipment Supplies 24 V DC within the cabinet power arrangement
Distributed Control Systems Power for associated automation hardware Supports the electrical infrastructure of a DeltaV installation
Chemical Processing Facilities Cabinet-based power distribution for process automation Supplies compatible DC loads in instrumentation and control cabinets
Oil and Gas Control Panels DC power for control-system equipment Forms part of the cabinet’s power-supply arrangement
Industrial Utility Systems DC power for monitoring and automation hardware Supports equipment requiring a compatible 24 V DC source
Control-System Maintenance Replacement of an existing power supply Can be considered when the installed system requires the VE5011 specification

Installation and Maintenance

  1. Verify the model reference: Confirm that the required unit is VE5011 and that its output ratings match the intended application.
  2. Check the incoming supply: Confirm that the AC source is within the unit’s permitted input range before connecting the supply.
  3. Calculate the connected load: Add the current requirements of all connected equipment and ensure that the total remains within the 5 A output rating.
  4. Inspect the mounting position: Install the unit on a suitable DIN rail in the intended orientation, with sufficient access for wiring and maintenance.
  5. Maintain ventilation clearance: Leave the required space around the power supply to support heat dissipation and avoid obstructing airflow.
  6. Verify terminal identification: Check the input, DC output, and signal terminals against the unit markings and the cabinet wiring documentation.
  7. Check polarity before energizing: Confirm the positive and negative DC connections to prevent wiring errors that could affect connected equipment.
  8. Provide suitable circuit protection: Select upstream protection appropriate to the supply, wiring, and connected load. Do not rely on internal fuse protection as the sole protective measure.
  9. Separate and secure wiring: Route conductors neatly, secure them against vibration, and follow the cabinet’s electrical wiring and grounding practices.
  10. Measure the output voltage: Before connecting sensitive loads, verify that the DC output is within the permitted range for the installed equipment.
  11. Check operation under load: Monitor the output during normal operation and investigate excessive voltage drop, unexpected resets, or signs of overheating.
  12. Inspect periodically: Check terminal tightness, wiring condition, mounting security, and ventilation. Isolate the supply as required before performing maintenance.

Related Components

Component Function Selection Considerations
DeltaV Controller Executes process-control logic Confirm the controller’s power requirements and system compatibility
DeltaV I/O Modules Interface with process signals Check module-specific power requirements and the approved installation arrangement
24 V DC Distribution Terminals Distribute DC power to connected equipment Current capacity, terminal rating, and wiring arrangement
Circuit Breaker or Fuse Provides upstream circuit protection Select according to the input supply, wiring, and applicable requirements
DIN Rail Supports cabinet-mounted equipment Verify mounting compatibility and available space
DC Wiring Carries supply power to connected loads Conductor size, insulation rating, length, and current capacity
Cabinet Grounding Hardware Establishes required grounding and bonding Follow the cabinet design and applicable electrical standards
Redundancy Module Supports redundant power arrangements where required Verify compatibility, load-sharing requirements, and the overall power architecture

Recommended Related Models

Model Product Description Application Context
VE5011 DeltaV Bulk Power Supply Reference model for applications requiring the specified 24 V DC, 5 A supply
DeltaV 10 A Bulk Power Supply Higher-current bulk power supply configuration Consider when the calculated DC load exceeds the capacity of a 5 A supply
DeltaV 20 A Bulk Power Supply Higher-current bulk power supply configuration Consider for larger DC loads, subject to system requirements
DeltaV Bulk Power Supply Redundancy Module Power-system redundancy component Relevant where the design requires a redundant supply arrangement

The related power-supply configurations differ in output capacity and installation requirements. Select a unit based on the required output voltage, total load current, input supply, mounting arrangement, and redundancy needs.


Key Advantages

  • 24 V DC output: Supports compatible control-system loads using a common industrial DC supply.
  • 5 A current capacity: Provides up to the rated output current for appropriately sized loads.
  • DIN-rail mounting: Fits standard cabinet-based equipment layouts where compatible.
  • Compact dimensions: Helps conserve space in control cabinets.
  • Power-system role: Separates DC power conversion from the control and I/O processing functions.

Technical FAQs

What is the rated output of the Emerson VE5011?

The VE5011 is specified as a 24 V DC bulk power supply rated at 5 A, corresponding to a nominal output power of 120 W. The actual connected load must remain within the supply’s permitted operating limits.

How can I determine whether one VE5011 can power several devices?

Add the current requirements of all connected devices, including relevant startup and transient loads. The total must remain within the supply’s output rating, with appropriate allowance for the operating conditions and system requirements.

Does the VE5011 perform DeltaV control logic or process field signals?

No. Its function is power conversion and supply. Control execution and field-signal processing are handled by the corresponding controller and I/O hardware.

What should be checked if connected equipment loses power intermittently?

Check the AC input, DC output voltage under load, terminal connections, wiring condition, protective devices, and total load current. Also investigate whether the connected equipment is drawing more current than the supply can support.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501