Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Siemens 6AG2132-6HD01-4BB1 SIPLUS ET 200SP Digital Relay Output Module is a relay-based output component for distributed automation systems. Installed in a compatible ET 200SP station, it connects PLC output commands to external electrical circuits that require switching through relay contacts.
In a machine control cabinet, the module can be used for discrete switching tasks involving suitable control relays, contactor coils, indicator circuits, and other compatible electrical loads. The PLC determines when an output should change state, while the relay contact provides the switching action for the connected circuit. This arrangement separates the control logic from the circuit being switched.
When replacing the module in an existing installation, technicians need to check the complete order number, station configuration, base-unit arrangement, terminal assignments, and electrical requirements of the connected loads. These details are important because modules in the same product family may have different output characteristics or installation requirements.
| Parameter | Specification |
|---|---|
| Manufacturer | Siemens |
| Product Model | 6AG2132-6HD01-4BB1 |
| Product Family | SIPLUS ET 200SP |
| Product Type | Digital Relay Output Module |
| Module Category | Distributed I/O |
| Output Type | Relay Output |
| Signal Type | Digital Output |
| Control System | Compatible PLC and ET 200SP I/O Station |
| Switching Interface | Relay Contacts |
| Installation Type | Distributed I/O Station |
| System Integration | ET 200SP Automation Architecture |
| Primary Function | Switching External Electrical Circuits |
| Maintenance Approach | Module Inspection, Wiring Checks, and Replacement |
| Dimensions | 20 × 73 × 58 mm |
| Weight | 0.052 kg |
The Siemens 6AG2132-6HD01-4BB1 operates as the relay output stage of a compatible ET 200SP distributed I/O station. The PLC generates digital output commands according to the control program, while the ET 200SP station transfers the output data to the module.
When an output command is activated, the module operates the corresponding relay contact to switch the connected external circuit. Depending on the application, this circuit may control an intermediate relay, contactor coil, indicator, or another electrical load within the specified switching ratings. The relay contact changes state according to the output command, allowing the external circuit to respond to the control system.
The connected load receives power from its designated external circuit rather than from the output command itself. The module provides the switching action, while the external supply and wiring determine how electrical power reaches the controlled device. For inductive loads, suitable suppression may be required to limit switching transients and reduce stress on the relay contacts.
The primary output path is:
PLC → ET 200SP Interface Module → 6AG2132-6HD01-4BB1 → Relay Contact → External Load
The feedback path depends on the wider automation configuration. If the controlled device has separate status feedback, that signal can return through an appropriate input channel to the PLC, allowing the control program to compare the commanded output with the actual equipment state.
The 6AG2132-6HD01-4BB1 occupies the output layer of a distributed automation system. It converts digital output data received through the ET 200SP station into relay switching actions for connected external circuits. Its role is therefore tied to the PLC program, the station configuration, and the electrical characteristics of the controlled devices.
| System Component | Function | Relationship to the Relay Output Module |
|---|---|---|
| PLC or Automation Controller | Executes the machine or process program | Generates the digital output commands |
| ET 200SP Interface Module | Connects the distributed I/O station to the controller | Transfers control data between the controller and station |
| ET 200SP Station | Houses the modular I/O components | Provides the installation environment for the module |
| 6AG2132-6HD01-4BB1 | Switches external circuits through relay contacts | Performs the assigned digital output function |
| Base Unit | Provides module mounting and electrical connections | Supports installation and field wiring |
| External Power Supply | Supplies power to the connected load | Provides the electrical energy for the switched circuit |
| Intermediate Relay or Contactor | Switches a downstream circuit | May respond to the module’s relay output when electrically compatible |
| Field Device | Performs the commanded action | Responds to the switched electrical circuit |
| Application Area | Typical Use | Relevance of the Relay Output Module |
|---|---|---|
| Machine Automation | Switching auxiliary circuits according to PLC commands | Connects discrete control logic with external switching circuits |
| Packaging Equipment | Controlling suitable indicators, relays, and auxiliary devices | Supports programmed switching sequences |
| Automated Assembly | Switching control circuits for machine mechanisms | Provides relay-based output control within the distributed I/O system |
| Material Handling | Controlling compatible auxiliary equipment | Supports discrete switching functions in handling machinery |
| Process Equipment | Switching electrical circuits in local control panels | Connects distributed control outputs with compatible field circuits |
| Industrial Control Cabinets | Maintaining or replacing installed output modules | Provides a specific part reference for service and inventory records |
| Equipment Refurbishment | Restoring existing ET 200SP assemblies | Supports replacement planning after hardware compatibility checks |
| Component | Function | Relationship to the Module |
|---|---|---|
| Siemens ET 200SP Interface Module | Connects the I/O station to the automation controller | Transfers control data to and from the station |
| Siemens ET 200SP Base Unit | Provides mounting and electrical connections | Supports module installation and field wiring |
| Siemens PLC | Executes the control program | Generates digital output commands |
| Industrial Control Power Supply | Supplies power to control and field circuits | Powers the relevant control and load circuits |
| Intermediate Relay | Switches a downstream electrical circuit | Can provide an additional switching stage where required |
| Contactor | Switches suitable electrical power circuits | May be controlled through an appropriately rated relay arrangement |
| Terminal Blocks | Provide field wiring termination points | Organize connections between the control cabinet and external devices |
| Surge Suppression Component | Limits switching transients in suitable circuits | Helps reduce electrical stress from inductive loads when correctly selected |
| Model or Product Category | Product Type | Relationship |
|---|---|---|
| Siemens 6AG2132-6HD01-4BB1 | SIPLUS ET 200SP Digital Relay Output Module | Exact model reference for identification and replacement |
| Siemens ET 200SP Digital Output Modules | Distributed Digital Output Modules | Related category for discrete output applications |
| Siemens ET 200SP Digital Input Modules | Distributed Digital Input Modules | Complementary category for receiving field status signals |
| Siemens ET 200SP Interface Modules | Distributed I/O Interface Modules | Related station components for controller communication |
| Siemens ET 200SP Base Units | I/O Mounting and Connection Components | Related components for module installation and field wiring |
| Siemens SIPLUS ET 200SP I/O Modules | Distributed I/O Modules | Related product family for compatible SIPLUS automation installations |
It is a digital relay output module used in a compatible SIPLUS ET 200SP station. It switches external electrical circuits in response to digital commands from the automation controller.
Check the complete order number, ET 200SP station configuration, base-unit arrangement, terminal assignments, and connected load requirements. A module with a similar appearance or product-family designation should not be assumed to be interchangeable.
That depends on the coil’s electrical requirements and the module’s applicable relay contact ratings. Verify the switching voltage, current, load characteristics, and any required suppression measures before connecting the coil.
Start by confirming that the PLC issues the expected output command and that the I/O station is correctly configured. Then inspect module seating, terminal wiring, the external circuit supply, the relay contact path, and the connected load. Separate feedback from the controlled device can help determine whether the commanded action actually occurred.