The Siemens 6AG1503-3CC00-2AA0 SIPLUS NET OLM/G12-1300 V4.0 Optical Link Module is an industrial optical communication module for connecting compatible PROFIBUS network segments through fiber-optic transmission. It belongs to the SIPLUS NET OLM family and is suited to automation installations where network communication must extend across separated equipment areas or electrically demanding environments.
The OLM/G12-1300 is typically installed as part of the communication infrastructure between PROFIBUS equipment and an optical transmission path. This arrangement is useful when control cabinets, remote I/O stations, drives, or field devices are located away from the primary controller and a fiber-based communication route is preferred.
Within a PROFIBUS architecture, the module handles the communication interface rather than executing control logic. The PLC or PROFIBUS master continues to manage the automation application, while the optical link module transfers network traffic between the connected electrical and fiber-optic sections.
The SIPLUS version can be integrated into industrial automation installations where environmental conditions are more demanding than those normally associated with standard automation equipment, subject to the applicable system requirements.
| Parameter | Specification |
|---|---|
| Manufacturer | Siemens |
| Model | 6AG1503-3CC00-2AA0 |
| Product Family | SIPLUS NET OLM |
| Product Series | OLM/G12-1300 V4.0 |
| Product Type | Optical Link Module |
| Primary Function | PROFIBUS optical communication interface |
| System Role | Industrial network communication module |
| Typical Application | PROFIBUS and fiber-optic industrial communication |
| Dimensions | 39.5 × 112 × 74.5 mm |
| Weight | 0.431 kg |
The 6AG1503-3CC00-2AA0 receives communication data from a connected PROFIBUS segment and transfers the network traffic through its optical communication interface. At the receiving side, another compatible optical network interface converts the transmitted optical communication back into the corresponding network connection.
PROFIBUS Segment → OLM/G12-1300 → Fiber-Optic Link → Remote OLM / Network Interface → PROFIBUS Segment
The fiber-optic path allows communication to continue between equipment locations without relying on a continuous copper connection between those areas. This can be useful for separated control cabinets, remote field equipment, and installations where electromagnetic interference is a concern.
The OLM/G12-1300 does not execute PLC programs or control field devices directly. Its function remains within the communication layer, transferring PROFIBUS network traffic so that the connected automation devices can exchange process and diagnostic information.
The OLM/G12-1300 forms part of the network infrastructure between the electrical PROFIBUS segment and the fiber-optic communication route.
PROFIBUS Master → Electrical PROFIBUS Network → OLM/G12-1300 → Fiber-Optic Network → Remote Optical Interface → PROFIBUS Devices
| System Element | Function |
|---|---|
| PROFIBUS Master / PLC | Executes automation control logic |
| Electrical PROFIBUS Segment | Carries fieldbus communication between local devices |
| 6AG1503-3CC00-2AA0 | Provides the optical communication interface |
| Fiber-Optic Network | Transfers network traffic between separated locations |
| Remote Optical Interface | Provides the corresponding optical network connection |
| Remote I/O / Drives | Exchanges process and control information |
| Engineering Station | Supports configuration, commissioning, and diagnostics |
This architecture allows the physical communication route to be adapted to plant layout and environmental conditions while leaving control logic with the connected automation controller.
| Application | Typical Use |
|---|---|
| Process Automation | Fiber-based PROFIBUS communication between control areas |
| Manufacturing Lines | Communication between separated automation cabinets |
| Remote I/O Systems | Network connection to distributed I/O equipment |
| Machine Automation | Optical communication between machine control sections |
| Power and Utility Facilities | Communication across electrically demanding plant areas |
| Industrial Plants | Fiber links between remote control and field locations |
| Electrically Noisy Areas | Communication infrastructure with reduced copper exposure |
| Component | Function |
|---|---|
| Siemens SIMATIC S7 Controller | Provides PROFIBUS control and master functions |
| PROFIBUS Network Components | Provides the electrical fieldbus communication path |
| Fiber-Optic Cable | Transfers network communication between optical interfaces |
| PROFIBUS Connectors | Provides electrical network connections |
| Remote I/O Stations | Exchanges process data with the automation controller |
| PROFIBUS Drives | Exchanges drive commands and operating information |
| Additional OLM Units | Establishes corresponding optical communication links |
| Engineering Station | Supports network configuration and diagnostics |
| Model / Product Family | Product Type | Typical Application |
|---|---|---|
| Siemens 6AG1503-2CA01-2AA0 | SIPLUS NET OLM/P11 V4.1 Optical Link Module | PROFIBUS optical communication |
| Siemens 6AG1503-2CB00-2AA0 | SIPLUS NET OLM/G11 V4.0 Optical Link Module | PROFIBUS fiber-optic network connection |
| Siemens 6AG1503-2CC00-2AA0 | SIPLUS NET OLM/G11-1300 V4.0 Optical Link Module | PROFIBUS optical communication |
| Siemens 6AG1503-3CA01-2AA0 | SIPLUS NET OLM/P12 V4.1 Optical Link Module | PROFIBUS optical communication |
| Siemens 6AG1503-3CB00-2AA0 | SIPLUS NET OLM/G12 V4.0 Optical Link Module | PROFIBUS optical communication |
| Siemens SIPLUS NET OLM Series | Optical Link Module Family | Industrial PROFIBUS network infrastructure |
| Siemens PROFIBUS Network Components | Fieldbus Communication Components | PROFIBUS network construction |
The OLM/G12-1300 is a specific optical-link configuration within the OLM family. When replacing an installed unit, the exact model and existing optical network arrangement should be matched rather than selecting a module solely because it belongs to the same OLM family.
Start by checking the local PROFIBUS segment and its connectors, then inspect the optical connections and fiber path. The remote OLM or corresponding optical interface should also be checked before isolating the fault to the local module.
Not necessarily. Replacement depends on the existing PROFIBUS topology, optical interface arrangement, connected network equipment, and system configuration. The complete communication architecture should be checked before substitution.
Contamination or damage at fiber connectors, excessive cable bending, poor connections, and faults in the corresponding remote optical interface can interrupt communication. Checking the complete optical path is more effective than testing the OLM alone.