Product Overview The Siemens 6AG1503-3CC00-2AA0 SIPLUS NET OLM/G12-1300 V4.0 Optical Link Module is an industrial optical communication module for connecting compatible PROFIBUS network segments through……
Siemens 6AG1503-3CC00-2AA0 SIPLUS NET OLM/G12-1300 V4.0 Optical Link Module
  • Siemens
  • 6AG1503-3CC00-2AA0
  • Optical Link Module
  • Germany
  • 39.5 × 112 × 74.5 mm
  • 0.431 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 6

Our advantage

Siemens 6AG1503-3CC00-2AA0 SIPLUS NET OLM/G12-1300 V4.0 Optical Link Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Siemens 6AG1503-3CC00-2AA0 SIPLUS NET OLM/G12-1300 V4.0 Optical Link Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Siemens 6AG1503-3CC00-2AA0 SIPLUS NET OLM/G12-1300 V4.0 Optical Link Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Siemens 6AG1503-3CC00-2AA0 SIPLUS NET OLM/G12-1300 V4.0 Optical Link Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Siemens 6AG1503-3CC00-2AA0 SIPLUS NET OLM/G12-1300 V4.0 Optical Link Module is an industrial optical communication module for connecting compatible PROFIBUS network segments through fiber-optic transmission. It belongs to the SIPLUS NET OLM family and is suited to automation installations where network communication must extend across separated equipment areas or electrically demanding environments.

The OLM/G12-1300 is typically installed as part of the communication infrastructure between PROFIBUS equipment and an optical transmission path. This arrangement is useful when control cabinets, remote I/O stations, drives, or field devices are located away from the primary controller and a fiber-based communication route is preferred.

Within a PROFIBUS architecture, the module handles the communication interface rather than executing control logic. The PLC or PROFIBUS master continues to manage the automation application, while the optical link module transfers network traffic between the connected electrical and fiber-optic sections.

The SIPLUS version can be integrated into industrial automation installations where environmental conditions are more demanding than those normally associated with standard automation equipment, subject to the applicable system requirements.


Technical Specifications

Parameter Specification
Manufacturer Siemens
Model 6AG1503-3CC00-2AA0
Product Family SIPLUS NET OLM
Product Series OLM/G12-1300 V4.0
Product Type Optical Link Module
Primary Function PROFIBUS optical communication interface
System Role Industrial network communication module
Typical Application PROFIBUS and fiber-optic industrial communication
Dimensions 39.5 × 112 × 74.5 mm
Weight 0.431 kg

Product Features

  • SIPLUS NET OLM/G12-1300 V4.0 Optical Link Module
  • Provides optical interfacing for compatible PROFIBUS communication networks
  • Supports fiber-optic transmission between separated network sections
  • Suitable for distributed industrial automation architectures
  • Useful for communication routes passing through electrically noisy plant areas
  • Supports network connections between control cabinets and remote equipment
  • Suitable for Siemens PROFIBUS communication infrastructure
  • SIPLUS product configuration for applicable demanding industrial environments

Working Principle

The 6AG1503-3CC00-2AA0 receives communication data from a connected PROFIBUS segment and transfers the network traffic through its optical communication interface. At the receiving side, another compatible optical network interface converts the transmitted optical communication back into the corresponding network connection.

PROFIBUS Segment → OLM/G12-1300 → Fiber-Optic Link → Remote OLM / Network Interface → PROFIBUS Segment

The fiber-optic path allows communication to continue between equipment locations without relying on a continuous copper connection between those areas. This can be useful for separated control cabinets, remote field equipment, and installations where electromagnetic interference is a concern.

The OLM/G12-1300 does not execute PLC programs or control field devices directly. Its function remains within the communication layer, transferring PROFIBUS network traffic so that the connected automation devices can exchange process and diagnostic information.


Role in a PROFIBUS Optical Communication Architecture

The OLM/G12-1300 forms part of the network infrastructure between the electrical PROFIBUS segment and the fiber-optic communication route.

PROFIBUS Master → Electrical PROFIBUS Network → OLM/G12-1300 → Fiber-Optic Network → Remote Optical Interface → PROFIBUS Devices

System Element Function
PROFIBUS Master / PLC Executes automation control logic
Electrical PROFIBUS Segment Carries fieldbus communication between local devices
6AG1503-3CC00-2AA0 Provides the optical communication interface
Fiber-Optic Network Transfers network traffic between separated locations
Remote Optical Interface Provides the corresponding optical network connection
Remote I/O / Drives Exchanges process and control information
Engineering Station Supports configuration, commissioning, and diagnostics

This architecture allows the physical communication route to be adapted to plant layout and environmental conditions while leaving control logic with the connected automation controller.


Industrial Applications

Application Typical Use
Process Automation Fiber-based PROFIBUS communication between control areas
Manufacturing Lines Communication between separated automation cabinets
Remote I/O Systems Network connection to distributed I/O equipment
Machine Automation Optical communication between machine control sections
Power and Utility Facilities Communication across electrically demanding plant areas
Industrial Plants Fiber links between remote control and field locations
Electrically Noisy Areas Communication infrastructure with reduced copper exposure

Installation and Maintenance

  1. Verify that the 6AG1503-3CC00-2AA0 matches the intended PROFIBUS and optical network architecture.
  2. Confirm the required network topology and identify all connected electrical and optical segments before installation.
  3. Mount the OLM/G12-1300 in the approved communication or control-panel location.
  4. Check PROFIBUS cable connections and connector assignments before applying power.
  5. Confirm that each optical connection is routed to the intended remote communication interface.
  6. Keep fiber-optic connectors protected from dust, moisture, and contamination during installation.
  7. Avoid excessive bending, pulling, twisting, or mechanical stress on fiber-optic cables.
  8. Inspect both electrical and optical connections for visible damage or poor seating.
  9. Apply power and check the module’s diagnostic or communication indications.
  10. Verify communication between the local PROFIBUS devices and the remote network section.
  11. If communication becomes unstable, isolate the electrical PROFIBUS segment, optical path, connectors, and remote interface separately.
  12. After replacement, perform a complete network communication test before returning the connected automation system to normal operation.

Compatible System Components

Component Function
Siemens SIMATIC S7 Controller Provides PROFIBUS control and master functions
PROFIBUS Network Components Provides the electrical fieldbus communication path
Fiber-Optic Cable Transfers network communication between optical interfaces
PROFIBUS Connectors Provides electrical network connections
Remote I/O Stations Exchanges process data with the automation controller
PROFIBUS Drives Exchanges drive commands and operating information
Additional OLM Units Establishes corresponding optical communication links
Engineering Station Supports network configuration and diagnostics

Recommended Related Models

Model / Product Family Product Type Typical Application
Siemens 6AG1503-2CA01-2AA0 SIPLUS NET OLM/P11 V4.1 Optical Link Module PROFIBUS optical communication
Siemens 6AG1503-2CB00-2AA0 SIPLUS NET OLM/G11 V4.0 Optical Link Module PROFIBUS fiber-optic network connection
Siemens 6AG1503-2CC00-2AA0 SIPLUS NET OLM/G11-1300 V4.0 Optical Link Module PROFIBUS optical communication
Siemens 6AG1503-3CA01-2AA0 SIPLUS NET OLM/P12 V4.1 Optical Link Module PROFIBUS optical communication
Siemens 6AG1503-3CB00-2AA0 SIPLUS NET OLM/G12 V4.0 Optical Link Module PROFIBUS optical communication
Siemens SIPLUS NET OLM Series Optical Link Module Family Industrial PROFIBUS network infrastructure
Siemens PROFIBUS Network Components Fieldbus Communication Components PROFIBUS network construction

Key Advantages

  • Provides optical communication interfacing for compatible PROFIBUS networks.
  • Supports fiber-based links between separated automation areas.
  • Suitable for communication routes where electrical interference is a concern.
  • Helps connect distributed PROFIBUS equipment through an optical network infrastructure.
  • Suitable for cabinet-to-cabinet and remote-area communication arrangements.
  • Integrates into Siemens SIPLUS industrial communication architectures.

Technical FAQs

What distinguishes the OLM/G12-1300 from a standard OLM/G12 installation?

The OLM/G12-1300 is a specific optical-link configuration within the OLM family. When replacing an installed unit, the exact model and existing optical network arrangement should be matched rather than selecting a module solely because it belongs to the same OLM family.

How should a communication fault be traced when the optical link is involved?

Start by checking the local PROFIBUS segment and its connectors, then inspect the optical connections and fiber path. The remote OLM or corresponding optical interface should also be checked before isolating the fault to the local module.

Can the 6AG1503-3CC00-2AA0 replace another OLM model directly?

Not necessarily. Replacement depends on the existing PROFIBUS topology, optical interface arrangement, connected network equipment, and system configuration. The complete communication architecture should be checked before substitution.

What maintenance issue is most likely to affect an optical communication link?

Contamination or damage at fiber connectors, excessive cable bending, poor connections, and faults in the corresponding remote optical interface can interrupt communication. Checking the complete optical path is more effective than testing the OLM alone.