• Schneider METSEDM6000 PowerLogic DM6000 Digital Meter With Basic Readings
  • Schneider METSEDM6000 PowerLogic DM6000 Digital Meter With Basic Readings
  • Schneider METSEDM6000 PowerLogic DM6000 Digital Meter With Basic Readings
  • Schneider METSEDM6000 PowerLogic DM6000 Digital Meter With Basic Readings
Product Overview The Schneider METSEDM6000 PowerLogic DM6000 Digital Meter With Basic Readings is a panel-mounted digital metering device for monitoring fundamental electrical measurements in low-voltag……
Schneider METSEDM6000 PowerLogic DM6000 Digital Meter With Basic Readings
  • Schneider
  • METSEDM6000
  • Digital Meter
  • France
  • 96 × 80 × 96 mm
  • 0.4 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 29

Our advantage

Schneider METSEDM6000 PowerLogic DM6000 Digital Meter With Basic Readings

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider METSEDM6000 PowerLogic DM6000 Digital Meter With Basic Readings

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider METSEDM6000 PowerLogic DM6000 Digital Meter With Basic Readings

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider METSEDM6000 PowerLogic DM6000 Digital Meter With Basic Readings

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider METSEDM6000 PowerLogic DM6000 Digital Meter With Basic Readings is a panel-mounted digital metering device for monitoring fundamental electrical measurements in low-voltage power distribution and industrial electrical systems. It gives operators and maintenance personnel a local view of electrical operating conditions without requiring a full supervisory system.

The DM6000 is suited to distribution boards, control panels, building electrical systems, and industrial equipment where basic electrical readings need to be checked during normal operation or maintenance. It can be used as a local metering point alongside circuit protection, switching equipment, and other PowerLogic devices.

In a typical installation, the meter receives electrical measurement signals from the monitored circuit and presents the corresponding readings on its display. This allows personnel to observe operating conditions and identify changes in electrical loading or other measured parameters during equipment operation.

The meter is primarily a measurement and indication device. It does not replace the protection functions of circuit breakers or the control logic of a PLC. Its measurements can instead complement the information available from the wider electrical distribution or automation system.


Technical Specifications

Parameter Specification
Manufacturer Schneider Electric
Model METSEDM6000
Product Family PowerLogic DM6000
Product Type Digital Meter With Basic Readings
Primary Function Electrical measurement and local digital display
System Role Power monitoring and measurement
Application Electrical distribution and industrial power systems
Dimensions 96 × 80 × 96 mm
Weight 0.4 kg

Product Features

  • PowerLogic DM6000 digital metering platform.
  • Provides local display of basic electrical readings.
  • Suitable for panel-based electrical monitoring.
  • Can be installed in industrial and commercial power distribution systems.
  • Provides operators with direct access to measured electrical information.
  • Useful for routine electrical inspection and maintenance.
  • Can complement circuit protection and power-distribution equipment.
  • Suitable for applications where basic local metering is required.

Working Principle

The METSEDM6000 monitors electrical quantities from the connected power circuit through its measurement inputs. The meter processes the incoming electrical signals and presents the resulting measurements as digital readings for local observation.

During normal operation, personnel can use the displayed information to assess the electrical condition of the monitored circuit. Changes in measured values can help identify variations in loading or operating conditions and can provide useful information during commissioning and troubleshooting.

Electrical Circuit → Measurement Inputs → METSEDM6000 → Digital Readings → Operator / Maintenance Personnel

The meter’s function is focused on measurement and indication. Protective action remains the responsibility of associated protective devices, while automated equipment control is handled by the relevant control system.


Role in a PowerLogic Electrical Monitoring Architecture

The METSEDM6000 occupies the measurement and local indication layer of an electrical distribution system. It can be installed at a panel or distribution point where personnel need direct access to basic electrical operating information.

Electrical Supply → Distribution / Protection → Metering Point → METSEDM6000 → Local Display

System Element Function
Incoming Electrical Supply Provides power to the distribution system
Circuit Protection Protects electrical circuits against abnormal conditions
Distribution Equipment Routes electrical power to connected loads
METSEDM6000 Measures and displays basic electrical readings
Operator / Maintenance Observes electrical conditions and performs checks
Power Monitoring System Uses available metering information for wider analysis

The meter can therefore provide a local measurement reference while the surrounding electrical system handles protection, switching, and higher-level monitoring functions.


Industrial Applications

Application Typical Use
Electrical Distribution Panels Local monitoring of circuit operating conditions
Industrial Control Panels Electrical readings for machine-side maintenance
Building Power Systems Basic electrical monitoring at distribution points
Manufacturing Facilities Monitoring of electrical operating conditions
Motor Control Installations Local observation of electrical loading
Commercial Electrical Systems Panel-level power measurement
Utility Distribution Equipment Local electrical status observation
Maintenance Panels Routine inspection and troubleshooting of circuits

Installation and Maintenance

  1. Verify that the METSEDM6000 is suitable for the intended electrical measurement application before installation.
  2. De-energize the applicable circuit and follow the site’s electrical safety procedures before wiring the meter.
  3. Confirm the measurement wiring against the approved electrical schematic.
  4. Inspect terminals and conductors for damage, loose connections, or incorrect identification.
  5. Install the meter securely in the designated panel position.
  6. Verify that all measurement connections are correctly assigned before energizing the circuit.
  7. Check the meter configuration against the characteristics of the monitored electrical system.
  8. Energize the system under controlled conditions and confirm that the displayed readings are reasonable.
  9. Compare meter indications with an appropriate reference measurement during commissioning when required.
  10. Investigate abnormal readings by checking the measurement wiring, circuit condition, and meter configuration.
  11. Keep the display and front surface clean and inspect the unit for physical damage during scheduled maintenance.
  12. After replacement, verify the measurement connections, configuration, displayed readings, and integration with any connected monitoring system before returning the panel to normal operation.

Compatible System Components

Component Function
Schneider PowerLogic Devices Electrical measurement and power monitoring
Circuit Breakers Electrical circuit protection and switching
Distribution Boards Routes electrical power to connected circuits
Current Transformers Provides current measurement signals where applicable
Voltage Measurement Circuits Provides voltage information to the meter
Contactors / Switchgear Controls and switches electrical loads
Power Monitoring System Collects and analyzes electrical measurement data
Control Panel Houses metering, protection, and control equipment

Recommended Related Models

Model / Product Family Product Type Typical Application
Schneider PowerLogic DM6000 Digital Meter Family Basic electrical measurement
Schneider PowerLogic DM6000 Series Digital Meter Panel-mounted power monitoring
Schneider PowerLogic PM2000 Power Meter Basic power and electrical measurement
Schneider PowerLogic PM5000 Power Meter Advanced electrical power monitoring
Schneider PowerLogic PM8000 Power Meter Advanced power-quality and energy analysis
Schneider PowerLogic Power Monitoring Family Electrical distribution monitoring
Schneider Modicon Automation Platform Industrial control and machine automation

Key Advantages

  • Provides local digital access to basic electrical readings.
  • Suitable for panel-level monitoring in electrical distribution systems.
  • Gives maintenance personnel a direct measurement reference at the installation point.
  • Can complement circuit protection, switchgear, and wider power-monitoring equipment.
  • Useful for routine inspection, commissioning, and electrical troubleshooting.
  • Fits PowerLogic-based electrical monitoring architectures.

Technical FAQs

Where is the METSEDM6000 typically installed?

It can be installed at an electrical distribution or control-panel measurement point where operators need local access to basic electrical readings. The exact installation depends on the monitored circuit and the panel’s electrical design.

What should be verified before connecting the meter to an electrical circuit?

The measurement wiring, monitored circuit characteristics, terminal assignments, and meter configuration should be checked against the approved electrical documentation. The circuit should also be made safe before installation or wiring work begins.

Why might the displayed reading differ from another electrical meter?

Differences can result from measurement-point location, wiring, configuration, instrument accuracy, or the reference meter itself. The complete measurement path should be checked before determining that the METSEDM6000 is malfunctioning.

Can the METSEDM6000 replace a circuit protection device?

No. The meter provides measurement and local indication, while circuit breakers, fuses, and other protective equipment perform electrical protection functions. The meter should be treated as part of the monitoring layer rather than the protection layer.