• ABB REF 545 REF545KB133AAAA Machine Protection Terminal
  • ABB REF 545 REF545KB133AAAA Machine Protection Terminal
  • ABB REF 545 REF545KB133AAAA Machine Protection Terminal
  • ABB REF 545 REF545KB133AAAA Machine Protection Terminal
Product Overview The ABB REF 545 REF545KB133AAAA Machine Protection Terminal is a protection and control device for electrical power system applications. It belongs to ABB’s REF 545 family and is ……
ABB REF 545 REF545KB133AAAA Machine Protection Terminal
  • ABB
  • REF 545 REF545KB133AAAA
  • Machine Protection Terminal
  • Sweden (SE)
  • 265.9 × 223.7 × 235 mm
  • 8 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 5

Our advantage

ABB REF 545 REF545KB133AAAA Machine Protection Terminal

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

ABB REF 545 REF545KB133AAAA Machine Protection Terminal

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

ABB REF 545 REF545KB133AAAA Machine Protection Terminal

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

ABB REF 545 REF545KB133AAAA Machine Protection Terminal

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The ABB REF 545 REF545KB133AAAA Machine Protection Terminal is a protection and control device for electrical power system applications. It belongs to ABB’s REF 545 family and is used to monitor electrical operating conditions, identify abnormal states, and initiate appropriate protection or control actions within a substation or industrial power distribution system.

In a typical protection scheme, the terminal receives measurement and status information from the electrical network through current and voltage transformers, together with binary information from circuit breakers and other switching equipment. The protection functions evaluate these signals against configured operating criteria and determine whether a trip, alarm, or control response is required.

The terminal can be incorporated into protection and control panels where dependable monitoring of feeders, switchgear, and associated electrical equipment is required. It can also exchange operational information with higher-level automation or supervisory systems, allowing protection events and equipment status to be incorporated into the wider substation control architecture.

For replacement projects, the complete REF545KB133AAAA ordering code should be matched with the existing protection scheme, measurement inputs, communication arrangement, control logic, and configured protection functions. Particular attention should be given to the existing relay settings and external wiring before commissioning.


Technical Specifications

Parameter Specification
Model REF 545
Order Number REF545KB133AAAA
Product Family REF 545
Product Type Machine Protection Terminal
Manufacturer ABB
Primary Function Electrical protection and control
System Role Protection, monitoring, and control terminal
Typical Application Power system and industrial electrical protection
Dimensions 265.9 × 223.7 × 235 mm
Weight 8 kg

Product Features

  • Part of the ABB REF 545 protection and control family.
  • Monitors electrical system conditions for protection and control purposes.
  • Processes measurement and status information from connected electrical equipment.
  • Supports protection-oriented control functions within electrical installations.
  • Can interface with circuit breaker and switchgear control circuits.
  • Suitable for substation and industrial power system applications.
  • Can exchange protection and operational information with supervisory systems.
  • Suitable for protection system replacement and maintenance when the complete configuration is verified.

Working Principle

The terminal receives electrical measurements and equipment status signals from the protected installation. Current and voltage information, together with breaker and switchgear status, is processed by the protection logic configured in the terminal.

CT / VT Measurements + Switchgear Status → REF 545 → Protection Logic → Trip / Alarm / Control Command

Under normal conditions, the terminal continuously evaluates incoming measurements and equipment states. When an electrical quantity or equipment condition meets a configured protection criterion, the corresponding protection function identifies the abnormal condition.

The terminal can then initiate the appropriate response through its output and control interfaces. Depending on the protection scheme, this may involve issuing a breaker trip command, generating an alarm, or communicating the event to a higher-level control system.

This arrangement allows protection decisions to be made locally at the electrical installation while maintaining communication with the broader substation or plant automation system.


Role in an Electrical Protection and Control Architecture

The REF 545 REF545KB133AAAA operates at the protection and control layer between electrical measurement equipment and switching devices. It processes information from the power network and coordinates protection responses with circuit breakers and supervisory systems.

Power Network → CT / VT → REF 545 → Protection Decision → Circuit Breaker / Alarm → Power System

System Element Function
Current Transformers Provide current measurements from the protected circuit
Voltage Transformers Provide voltage information where required by the protection scheme
REF 545 Processes measurements and executes configured protection logic
Circuit Breaker Interrupts the protected circuit following a trip command
Switchgear Performs electrical switching and isolation functions
Station Control System Monitors protection and equipment status
HMI / SCADA Provides operator visualization and supervisory control

Industrial Applications

Application Typical Use
Electrical Substations Protection and control of power system equipment
Industrial Power Distribution Monitoring and protection of electrical feeders and switchgear
Manufacturing Plants Protection of plant electrical infrastructure
Power Generation Facilities Electrical protection and operational monitoring
Process Plants Protection and control of critical power distribution equipment
Switchgear Systems Integration of protection, measurement, and breaker control

Installation and Maintenance

  1. Verify the complete REF545KB133AAAA order number before installation.
  2. Confirm that the replacement terminal matches the existing protection scheme.
  3. Record and back up existing protection settings and configuration before replacement.
  4. Isolate the relevant electrical equipment according to the site’s safety procedures.
  5. Verify CT and VT wiring before connecting the terminal.
  6. Check binary input and output wiring against the existing protection drawings.
  7. Inspect communication connections and station-bus interfaces before startup.
  8. Install the terminal securely in the designated protection panel.
  9. Restore the required configuration and protection settings after installation.
  10. Perform secondary injection or other applicable protection tests before energizing the protected circuit.
  11. Verify breaker trip, alarm, indication, and communication functions under controlled test conditions.
  12. Monitor event records, alarms, and protection status after returning the system to service.

Related Components

Component Function
Current Transformer Supplies current measurement to the protection terminal
Voltage Transformer Supplies voltage measurement where required
Circuit Breaker Interrupts the electrical circuit following protection operation
Switchgear Provides switching and isolation of electrical equipment
Protection Test Equipment Used to verify configured protection functions
Station Control System Collects protection and equipment information
SCADA System Provides supervisory monitoring and event management
Communication Network Transfers protection and operational data

Recommended Related Models

Model / Product Family Product Type Typical Application
ABB REF 545 Machine Protection Terminal Electrical protection and control
ABB REF 54x Series Protection and Control Terminal Substation and industrial power systems
ABB REF 541 Protection and Control Terminal Feeder and electrical equipment protection
ABB REF 543 Protection and Control Terminal Substation protection and control
ABB REF 545 Protection and Control Terminal Machine and electrical system protection
ABB Relion Protection Family Protection and Control Relay Modern power system protection
ABB Current Transformers Measurement Component Current acquisition for protection
ABB Voltage Transformers Measurement Component Voltage acquisition for protection

Key Advantages

  • Combines electrical protection and control functions in a dedicated terminal.
  • Suitable for industrial and substation protection architectures.
  • Processes electrical measurements and equipment status information.
  • Supports integration with circuit breaker and switchgear control circuits.
  • Can connect protection functions with supervisory automation systems.
  • Suitable for maintenance and replacement of compatible REF 545 installations.

Technical FAQs

What signals are normally connected to an REF 545 protection terminal?

The protection scheme may include current and voltage measurements together with binary signals representing circuit breaker, disconnector, alarm, or equipment status. The exact signal arrangement depends on the configured protection application.

Why should CT wiring be checked carefully before commissioning?

Incorrect CT wiring can affect the magnitude or phase relationship of measured current and may cause incorrect protection behavior. CT polarity, phase assignment, secondary connections, and applicable test procedures should therefore be verified before the protected equipment is energized.

What should be checked if the terminal shows normal measurements but does not trip the breaker during a protection test?

Check the configured protection function, pickup settings, output mapping, trip circuit wiring, breaker interface, and blocking or interlocking conditions. The protection decision and the physical trip path should be tested separately to identify where the response is being interrupted.

What information should be preserved when replacing an REF545KB133AAAA?

The existing protection settings, configured functions, I/O assignments, communication parameters, and relevant event or commissioning records should be preserved where applicable. A replacement terminal should be commissioned against the documented protection scheme rather than relying only on the physical wiring.



Related Products