• Siemens 6AG1414-5HM06-7AB0 SIPLUS S7-400 CPU Module
  • Siemens 6AG1414-5HM06-7AB0 SIPLUS S7-400 CPU Module
  • Siemens 6AG1414-5HM06-7AB0 SIPLUS S7-400 CPU Module
  • Siemens 6AG1414-5HM06-7AB0 SIPLUS S7-400 CPU Module
Product Overview The Siemens 6AG1414-5HM06-7AB0 is a SIPLUS S7-400 CPU 414-5H central processing unit for high-availability SIMATIC S7-400 automation systems. It combines the processing capability of th……
Siemens 6AG1414-5HM06-7AB0 SIPLUS S7-400 CPU Module
  • Siemens
  • 6AG1414-5HM06-7AB0
  • CPU Module
  • Germany
  • 50 × 290 × 219 mm
  • 1.156 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 33

Our advantage

Siemens 6AG1414-5HM06-7AB0 SIPLUS S7-400 CPU Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Siemens 6AG1414-5HM06-7AB0 SIPLUS S7-400 CPU Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Siemens 6AG1414-5HM06-7AB0 SIPLUS S7-400 CPU Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Siemens 6AG1414-5HM06-7AB0 SIPLUS S7-400 CPU Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Siemens 6AG1414-5HM06-7AB0 is a SIPLUS S7-400 CPU 414-5H central processing unit for high-availability SIMATIC S7-400 automation systems. It combines the processing capability of the S7-400 platform with the redundancy functions required for applications where continued controller operation is a major system requirement.

The CPU 414-5H can be used as one of the two CPUs in an S7-400H redundant controller configuration. The paired CPUs exchange synchronization information and maintain coordinated controller operation so that a fault affecting one controller does not necessarily interrupt the controlled process.

The module also supports PROFINET and PROFIBUS DP communication, allowing the CPU to interface with distributed I/O, field devices, HMI systems, engineering stations, and other automation equipment. This makes it suitable for control architectures combining rack-based S7-400 modules with distributed network components.

As a SIPLUS version, the CPU is intended for industrial environments where extended environmental capability is required. It can be considered for process plants, utilities, production systems, and infrastructure installations that use S7-400H architecture and require additional environmental robustness.


Technical Specifications

Parameter Specification
Manufacturer Siemens
Model 6AG1414-5HM06-7AB0
Product Family SIPLUS S7-400
Product Type SIPLUS S7-400 CPU 414-5H
CPU Type CPU 414-5H
Controller Platform SIMATIC S7-400H
Controller Function High-availability CPU
Communication PROFINET / PROFIBUS DP
Application S7-400H and S7-400F/FH systems
Environmental Version SIPLUS
Dimensions 50 × 290 × 219 mm
Weight 1.156 kg

Product Features

  • CPU 414-5H platform for S7-400H high-availability systems.
  • Supports redundant controller architectures using paired CPUs.
  • Integrated PROFINET communication for Ethernet-based automation networks.
  • PROFIBUS DP connectivity for distributed field-level devices.
  • Supports synchronization between CPUs in redundant S7-400H configurations.
  • Suitable for process and infrastructure applications requiring high controller availability.
  • SIPLUS version provides enhanced environmental capability for demanding installations.
  • Integrates with the established SIMATIC S7-400 family of power supplies, I/O modules, communication components, and HMI systems.

Working Principle

Process Inputs → CPU 414-5H → User Program Execution → Redundant Controller Synchronization → Output Commands

The 6AG1414-5HM06-7AB0 executes the configured S7-400 control program and processes information received from local and distributed I/O. Input data is evaluated according to the user program, after which the CPU generates output commands and exchanges process information with connected automation devices.

In an S7-400H architecture, two CPUs operate together as a redundant controller pair. Synchronization connections allow the CPUs to maintain coordinated operating states. One CPU normally handles the active control task while the redundant CPU maintains the required synchronized state and can assume control when a fault occurs.

The communication architecture supports:

  • PROFINET communication with Ethernet-based automation devices.
  • PROFIBUS DP communication with distributed field devices and I/O.
  • Synchronization between redundant CPUs.
  • Exchange of process and diagnostic information with connected system components.
  • Centralized execution of the automation program for the S7-400 station.

The result is a controller architecture that combines conventional S7-400 control functions with redundancy and distributed communication.


Role in a SIMATIC S7-400H Control Architecture

Engineering Station / HMI → PROFINET / PROFIBUS Network → CPU 414-5H A ⇄ CPU 414-5H B → Distributed I/O → Field Equipment

System Element Function
6AG1414-5HM06-7AB0 CPU Executes the control program and participates in the redundant controller architecture
Redundant CPU Pair Maintains high-availability control operation
SYNC Modules Synchronize the redundant CPUs
S7-400 Rack Provides the backplane and installation infrastructure
S7-400 Power Supply Supplies power to the automation station
S7-400 Signal Modules Process local digital and analog field signals
PROFIBUS DP Devices Connect distributed field-level equipment
PROFINET Devices Connect Ethernet-based automation equipment
SIMATIC HMI Provides process visualization and operator control

Industrial Applications

Application Typical Use
Process Automation Redundant control of continuous production processes
Chemical Processing High-availability controller architectures for process equipment
Power Generation and Utilities Continuous control of auxiliary and utility systems
Water and Wastewater Redundant monitoring and control of treatment infrastructure
Oil and Gas Process and utility control where controller availability is important
Manufacturing Coordinated control of production equipment and distributed I/O
Infrastructure Automation Continuous operation of large-scale technical systems

Installation and Maintenance

  1. Verify that the CPU part number matches the planned S7-400H system configuration.
  2. Switch off the relevant rack power before installing or removing the CPU.
  3. Install the CPU in the specified S7-400 rack position.
  4. Connect the required PROFINET and PROFIBUS DP networks.
  5. Install the required synchronization components for the redundant controller arrangement.
  6. Load the correct hardware configuration and user program.
  7. Check CPU diagnostics, communication status, and redundancy configuration before commissioning.
  8. Verify communication with distributed I/O and connected operator systems.
  9. During maintenance, inspect rack contacts, communication connectors, network cables, and synchronization connections.
  10. Keep the installation environment within the applicable SIPLUS operating conditions.
  11. Back up the current program and hardware configuration before CPU replacement.
  12. After replacement, verify CPU configuration, synchronization status, network communication, I/O operation, and diagnostic information before returning the system to service.

Related Components / Compatible System Components

Component Function
S7-400H Rack Provides the mechanical and backplane infrastructure for the redundant controller
S7-400 Power Supply Module Supplies power to the controller station
S7-400H SYNC Modules Establish synchronization between redundant CPUs
S7-400 Signal Modules Provide local digital and analog process I/O
PROFIBUS DP Devices Connect distributed field equipment
PROFINET Devices Provide Ethernet-based industrial communication
SIMATIC Memory Card Stores controller program and configuration information
SIMATIC HMI Provides operator monitoring and control
Engineering Station Used for configuration, programming, commissioning, and diagnostics

Recommended Related Models

Model / Product Family Product Type Typical Application
Siemens 6AG1414-5HM06-7AB0 SIPLUS S7-400 CPU 414-5H High-availability S7-400H control
Siemens 6AG1412-5HK06-7AB0 SIPLUS S7-400 CPU 412-5H S7-400H redundant control
Siemens 6AG1416-5HS06-7AB0 SIPLUS S7-400 CPU 416-5H Higher-performance redundant automation
Siemens 6AG1417-5HT06-7AB0 SIPLUS S7-400 CPU 417-5H High-performance S7-400H applications
Siemens 6AG1414-3EM07-7AB0 SIPLUS S7-400 CPU 414-3 PN/DP S7-400 control with PN/DP communication
Siemens SIPLUS S7-400H Components High-availability System Components Redundant process automation systems

Key Advantages

  • Supports S7-400H high-availability controller architectures.
  • Provides CPU 414-5H processing for demanding automation applications.
  • Combines PROFINET and PROFIBUS DP communication capabilities.
  • Supports synchronized redundant CPU operation.
  • Integrates with the broad SIMATIC S7-400 ecosystem.
  • SIPLUS environmental capability makes it suitable for more demanding industrial installations.
  • Well suited to process and infrastructure systems where minimizing controller-related downtime is important.

Technical FAQs

What is the primary application of the 6AG1414-5HM06-7AB0?

The CPU is intended primarily for SIMATIC S7-400H high-availability automation systems. It can operate as part of a redundant CPU pair in applications where continued controller operation is important.

How does the CPU participate in an S7-400H redundant system?

Two compatible CPUs operate as a synchronized pair. The CPUs exchange synchronization information so that the standby controller maintains the required system state and can take over control when the active controller experiences a qualifying fault.

What communication networks can be connected to this CPU?

The CPU supports PROFINET and PROFIBUS DP communication. These interfaces allow connection to Ethernet-based automation equipment as well as PROFIBUS distributed I/O and field devices.

What should be considered when replacing this CPU in an existing S7-400H system?

The replacement must match the existing hardware and software configuration. The user program, hardware configuration, memory configuration, network parameters, synchronization components, and connected I/O should all be checked before commissioning the replacement CPU.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501