Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Emerson SE4005S2B1 DeltaV S-series Analog Output Card is used to send continuous analog control signals from a DeltaV control system to field equipment. It forms the output interface between control strategies running in the DeltaV controller and devices that require an analog command for regulating a process variable.
Typical field applications include control valves, variable-speed equipment, dampers, actuators, and other devices whose operating point must be adjusted continuously rather than simply switched on or off. The SE4005S2B1 allows these control commands to be incorporated into the DeltaV I/O architecture and routed toward the appropriate field circuit.
In a process-control loop, the controller calculates an output based on the measured process condition and configured control strategy. The analog output card then interfaces this command with the field device, allowing the equipment to respond proportionally to the requested operating condition.
The SE4005S2B1 is also relevant for distributed DeltaV installations where analog output functions are located close to process equipment. During maintenance, the complete signal path should be checked, including the controller configuration, I/O channel, termination, field wiring, and final control element.
| Parameter | Specification |
|---|---|
| Manufacturer | Emerson |
| Model | SE4005S2B1 |
| Product Family | DeltaV S-series |
| Product Type | Analog Output Card |
| Primary Function | Analog control signal output |
| System Role | Analog output interface |
| Application | Process control and continuous field-device regulation |
| Installation | DeltaV S-series I/O system |
| Dimensions | 131 × 41.8 × 130.8 mm |
| Weight | 0.4 kg |
The SE4005S2B1 receives an analog output command generated by the DeltaV control strategy and interfaces that command with the connected field circuit. The controller determines the required output according to the configured process strategy, while the I/O card serves as the hardware interface to the final control element.
DeltaV Controller → SE4005S2B1 → Field Wiring → Final Control Element → Process
For example, when a control loop determines that a valve needs to move toward a different operating position, the controller generates the corresponding analog command. The SE4005S2B1 transfers the command through the field interface, allowing the valve or other applicable device to change its operating condition.
Typical output applications include:
The resulting field action changes the process condition, which is then measured again by the corresponding input instrumentation. This creates the feedback path required for continuous automatic control.
The SE4005S2B1 operates at the output side of a DeltaV process-control loop. It takes the controller’s calculated command and transfers it to the physical equipment responsible for changing the process.
Process Measurement → DeltaV Controller → SE4005S2B1 → Final Control Element → Process Response
| System Element | Function |
|---|---|
| Process Sensor | Measures the controlled process variable |
| DeltaV Controller | Calculates the required control output |
| SE4005S2B1 | Interfaces the analog command with the field circuit |
| Field Wiring | Carries the output signal to the final control element |
| Control Valve / Actuator | Converts the command into physical movement |
| Process Equipment | Responds to the control action |
| Operator Interface | Displays process values, output status, and operating conditions |
The card therefore forms the final electronic interface between the DeltaV control algorithm and the equipment that physically changes the process.
| Application | Typical Use |
|---|---|
| Chemical Processing | Continuous regulation of valves and process equipment |
| Oil and Gas | Analog control of valves, actuators, and process equipment |
| Petrochemical Plants | Flow, pressure, and temperature regulation |
| Power Generation | Continuous control of applicable plant equipment |
| Pharmaceutical Production | Precise adjustment of process variables |
| Water and Wastewater | Control of valves, pumps, and treatment equipment |
| Food and Beverage | Regulation of process temperature, flow, and pressure |
| Manufacturing | Analog control of automated production equipment |
For analog output problems, it is useful to distinguish between a command-generation problem and a signal-transmission problem. If the controller is calculating the correct output but the field device does not respond, the investigation should continue through the I/O channel, termination, wiring, and final control element.
| Component | Function |
|---|---|
| DeltaV Controller | Executes control strategies and calculates output commands |
| DeltaV S-series I/O System | Provides the distributed I/O architecture |
| Analog Input Card | Acquires feedback from process instrumentation |
| Control Valve | Regulates process flow according to the output command |
| Valve Positioner | Converts the control signal into valve movement |
| Actuator | Performs the physical control action |
| Field Termination Assembly | Connects I/O signals to field wiring |
| Operator Workstation | Displays process values, outputs, alarms, and trends |
| Model / Product Family | Product Type | Typical Application |
|---|---|---|
| Emerson SE4005S2B1 | DeltaV S-series Analog Output Card | Continuous analog control |
| Emerson SE4003S2B1 | DeltaV S-series Analog Input Card | Process analog signal acquisition |
| Emerson SE4003S5B1 | DeltaV S-series Thermocouple Card | Thermocouple temperature measurement |
| Emerson SE4003S6B1 KJ3225X1-BK1 | DeltaV S-series RTD Input Card | RTD temperature acquisition |
| Emerson SE4003S7B1 | DeltaV S-series Isolated Input Card | Isolated field input acquisition |
| Emerson DeltaV S-series | S-series I/O Platform | Distributed process I/O |
The SE4005S2B1 is used to interface analog control commands from the DeltaV control system with applicable field devices that require continuous output control.
Depending on the overall instrumentation design, analog outputs can be used with devices such as control valves, valve positioners, actuators, dampers, and equipment requiring an analog reference or control signal.
First verify the controller’s commanded output and channel status. Then check the I/O card, termination, field wiring, and final control element. This separates a DeltaV configuration problem from an I/O or field-device problem.
The controller calculates an output based on the measured process variable and configured control strategy. The SE4005S2B1 transfers that command to the final control element, which changes the process condition. The resulting process response is measured again through input instrumentation, closing the control loop.