Product Overview The Emerson SE4002S2T1B1 DeltaV S-series Discrete Output Card is a field-output module used within an Emerson DeltaV control system to send discrete commands to connected process equipm……
Emerson SE4002S2T1B1 DeltaV S-series Discrete Output Card
  • Emerson
  • SE4002S2T1B1
  • Discrete Output Card
  • USA
  • 131 × 41.8 × 130.8 mm
  • 0.4 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 8

Our advantage

Emerson SE4002S2T1B1 DeltaV S-series Discrete Output Card

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Emerson SE4002S2T1B1 DeltaV S-series Discrete Output Card

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Emerson SE4002S2T1B1 DeltaV S-series Discrete Output Card

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Emerson SE4002S2T1B1 DeltaV S-series Discrete Output Card

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Emerson SE4002S2T1B1 DeltaV S-series Discrete Output Card is a field-output module used within an Emerson DeltaV control system to send discrete commands to connected process equipment.

In a typical plant, the control strategy needs to turn software decisions into physical actions. A pump may need to receive a start command after its permissives are satisfied, a valve may need to move to a defined position, or an external relay may need to be energized during a shutdown sequence. The SE4002S2T1B1 forms part of the interface between those DeltaV commands and the field control circuit.

The module handles discrete, state-based commands rather than continuously varying process values. Depending on the application, an output channel may be associated with functions such as START/STOP, OPEN/CLOSE, ENABLE/DISABLE, RESET, or another binary control action configured within the control strategy.

A practical signal path can be viewed as:

DeltaV Control Logic → SE4002S2T1B1 → Termination → Field Wiring → Control Device

For example, a process sequence may require a transfer pump to start only after a suction valve has reached the required state. DeltaV evaluates the sequence conditions, sends the appropriate output command, and the field circuit then initiates the pump-control action.

The output card should not be treated as an isolated component when diagnosing a control problem. Termination hardware, field wiring, interposing relays, solenoids, motor-control circuits, actuators, and feedback inputs can all affect the final equipment response.


Technical Specifications

Parameter Specification
Manufacturer Emerson
Model SE4002S2T1B1
Product Family DeltaV S-series
Product Type Discrete Output Card
Primary Function Discrete Field Command Output
System Role Field Output Interface
Application Industrial Automation / Process Control
Installation Emerson DeltaV Control System
Dimensions 131 × 41.8 × 130.8 mm
Weight 0.4 kg

Product Features

The SE4002S2T1B1 is intended for DeltaV applications where binary control commands must be transferred from the controller to field equipment.

  • Emerson DeltaV S-series Discrete Output Card
  • Model SE4002S2T1B1
  • Discrete field-command output
  • Interfaces DeltaV control logic with field circuits
  • Suitable for equipment start/stop functions
  • Applicable to valve and solenoid control
  • Can form part of relay-based control circuits
  • Suitable for automated sequence operations
  • Applicable to equipment enable and reset functions
  • Useful in process-control and industrial automation systems
  • Suitable for maintenance and replacement applications

The function assigned to each output channel depends on the installed DeltaV configuration and the connected field circuit.


Working Principle

The SE4002S2T1B1 receives the output state determined by the DeltaV control application and transfers that command toward the associated field circuit.

The basic relationship is:

Control Decision → Discrete Output → Field Interface → Equipment

The control decision can originate from an operator command, automatic sequence, permissive logic, or programmed interlock.

Consider an on/off valve application. When the process sequence requires the valve to change state, DeltaV generates the corresponding command. The SE4002S2T1B1 transfers the discrete output condition through the configured I/O path. The field-side circuit then operates the relevant solenoid or actuator.

The sequence can be summarized as:

Valve Command → SE4002S2T1B1 → Solenoid / Actuator Circuit → Valve Movement

For motor-driven equipment, the arrangement may instead be:

Start Request → Output Channel → Motor-Control Circuit → Equipment Start

The important point during troubleshooting is that the output card handles the command path; it does not determine the overall process logic or guarantee that the downstream equipment will physically respond.


Field Command and Status Feedback

A discrete output normally represents what the control system requests, while a separate input can indicate what the equipment actually does.

For example:

DeltaV → SE4002S2T1B1 → Motor Control

can be paired with:

Motor Running Contact → Discrete Input → DeltaV

This distinction becomes valuable in automatic sequences. If the controller sends a start command but the expected running indication never appears, the engineer can determine whether the issue is related to the output path or the equipment itself.

The investigation may include:

  • Output channel state
  • Termination connection
  • Field wiring
  • Interposing relay
  • Motor-control circuit
  • Solenoid or actuator
  • Equipment condition
  • Feedback wiring
  • DeltaV configuration

This command-versus-feedback approach is particularly useful for commissioning and troubleshooting process equipment.


Role in a DeltaV S-series Control Architecture

The SE4002S2T1B1 sits on the discrete-output side of the DeltaV S-series I/O architecture.

A simplified control path is:

Operator / Automatic Sequence → DeltaV Controller → SE4002S2T1B1 → Field Interface → Process Equipment

System Element Function
SE4002S2T1B1 Transfers discrete output commands
DeltaV Controller Executes control and sequence logic
S-series I/O Infrastructure Connects control functions with field I/O
Termination Hardware Provides field wiring interface
Interposing Relay Interfaces external control circuits
Solenoid Performs binary actuation
Motor Control Circuit Receives equipment commands
Valve Actuator Executes valve movement
Discrete Input Card Returns equipment status
HMI Displays commands and operating conditions
Field Equipment Performs the requested action

This architecture allows the control application to issue field commands while separate input channels can monitor the resulting equipment state.


Typical Control Functions

Pump Start and Stop

The output can form part of a control circuit used to initiate or stop pump operation after the required logic conditions are met.

Valve Actuation

For on/off process valves, the discrete output may be associated with a solenoid or actuator control circuit.

Equipment Reset

A field device that requires a binary reset command can use a discrete output as part of its reset circuit.

Equipment Enable

Certain systems use discrete enable signals to permit equipment operation after predefined conditions have been satisfied.

Sequence-Based Actions

During startup, shutdown, transfer, isolation, or other automated procedures, individual discrete outputs can execute specific field actions at defined points in the sequence.


Industrial Applications

Application Typical Use
Oil and Gas Pump and valve control
Petrochemical Equipment sequencing and interlocks
Chemical Processing Solenoid and actuator operation
Power Generation Auxiliary equipment commands
Water Treatment Pump and valve operation
Manufacturing Machine start/stop control
Process Plants Automated equipment sequences
Material Handling Motor and conveyor commands

Installation and Maintenance

Before replacing an SE4002S2T1B1 in an operating DeltaV system, the installed channel assignment and field-side circuit should be identified carefully.

Recommended practices include:

  • Confirm the complete SE4002S2T1B1 model.
  • Verify the assigned DeltaV I/O position.
  • Review the configured channel assignments.
  • Identify the equipment controlled by each channel.
  • Record existing field wiring.
  • Inspect termination connections.
  • Check associated relays and interface devices.
  • Inspect field-side wiring.
  • Review the connected motor, solenoid, or actuator circuit.
  • Verify the DeltaV configuration.
  • Inspect module connectors.
  • Follow the approved equipment isolation procedure.
  • Install the replacement card.
  • Restore the field wiring.
  • Check module diagnostics.
  • Test representative output channels.
  • Confirm the commanded equipment response.
  • Verify corresponding feedback signals.
  • Check relevant alarms and interlocks.
  • Test the affected automatic sequence.
  • Record the completed maintenance configuration.

When the output indication is correct but the field equipment remains inactive, trace the command path from the module outward:

SE4002S2T1B1 → Termination → Wiring → Interface Device → Actuator / Motor Circuit → Equipment


Compatible System Components

The SE4002S2T1B1 can form part of a broader DeltaV field-control arrangement.

Component Function
Emerson SE4002S2T1B1 DeltaV S-series Discrete Output Card
DeltaV Controller Generates configured control commands
S-series I/O Infrastructure Provides system I/O connectivity
Termination Assembly Connects field wiring
Interposing Relay Interfaces external circuits
Solenoid Valve Performs discrete actuation
Motor Control Circuit Handles start/stop functions
Valve Actuator Executes commanded movement
Discrete Input Card Returns equipment feedback
HMI Displays equipment status
Field Wiring Carries discrete output signals

Recommended Related Models

For a related-product structure around DeltaV discrete control, the following models cover output commands as well as the input and event-monitoring functions commonly associated with them.

Model / Product Family Product Type Typical Application
Emerson SE4002S2T1B1 DeltaV S-series Discrete Output Card Discrete field command output
Emerson SE4002S1T2B1 DeltaV S-series Discrete Output Card Equipment control
Emerson SE4002S1T2B5 DeltaV S-series Discrete Output Card Field command applications
Emerson SE4002S1T2B6 DeltaV S-series Discrete Output Card Discrete equipment commands
Emerson SE4002S1T1B1 DeltaV S-series Discrete Output Card Discrete output control
Emerson SE4002S1T1B3 DeltaV S-series Discrete Output Card Field-side command functions
Emerson SE4001S3T2B2 DeltaV S-series Discrete Input Card Equipment status feedback
Emerson SE4001S5T2B5 DeltaV S-series Sequence of Event Input Card Event and sequence monitoring

Key Advantages

  • Emerson DeltaV S-series Discrete Output Card.
  • Model SE4002S2T1B1.
  • Transfers binary control commands to field circuits.
  • Suitable for pump and motor start/stop functions.
  • Applicable to valve and solenoid control.
  • Supports automated sequence actions.
  • Useful for equipment enable and reset functions.
  • Can be paired with discrete feedback inputs.
  • Suitable for DeltaV I/O maintenance and replacement work.

Technical FAQs

What kind of equipment can be controlled through the SE4002S2T1B1?

The card can form part of discrete control circuits for equipment such as pumps, motors, on/off valves, solenoids, relays, and other devices requiring defined binary commands. The actual field connection depends on the plant’s control-circuit design.

Why might a pump remain stopped even though the DeltaV output has changed state?

The output state only represents the command at the I/O level. Engineers should continue checking the termination, field wiring, interface relay, motor-control circuit, protective devices, and equipment condition. A missing running-status feedback should also be investigated separately.

How does the SE4002S2T1B1 support automatic process sequencing?

A DeltaV sequence can assign a discrete output action to a particular process step. When the required conditions are satisfied, the controller issues the command through the output channel. Subsequent sequence steps can depend on feedback or other configured conditions.

What should be checked before using this card as a replacement?

The complete model number, installed I/O position, channel assignments, field wiring, termination arrangement, connected equipment, and DeltaV configuration should be compared with the existing installation. After replacement, both the output command and the resulting field response should be verified.