• GE IC695PSD040 RX3i Universal Backplane Power Supply
  • GE IC695PSD040 RX3i Universal Backplane Power Supply
  • GE IC695PSD040 RX3i Universal Backplane Power Supply
  • GE IC695PSD040 RX3i Universal Backplane Power Supply
Product Overview The GE IC695PSD040 RX3i Universal Backplane Power Supply is a dedicated power supply module engineered for the PACSystems RX3i programmable automation platform. It provides regulated op……
GE IC695PSD040 RX3i Universal Backplane Power Supply
  • GE
  • IC695PSD040
  • RX3i Universal Backplane Power Supply
  • USA
  • 145 x 34 x 140 mm
  • 1.129 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 13

Our advantage

GE IC695PSD040 RX3i Universal Backplane Power Supply

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE IC695PSD040 RX3i Universal Backplane Power Supply

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE IC695PSD040 RX3i Universal Backplane Power Supply

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE IC695PSD040 RX3i Universal Backplane Power Supply

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE IC695PSD040 RX3i Universal Backplane Power Supply is a dedicated power supply module engineered for the PACSystems RX3i programmable automation platform. It provides regulated operating power to the RX3i universal backplane, ensuring reliable operation of CPUs, communication modules, specialty modules, and I/O modules installed within the control rack.

As the central power source of an RX3i system, the IC695PSD040 plays a critical role in maintaining controller stability and continuous industrial operation. It converts incoming power into the internal voltages required by the backplane while helping protect connected modules from abnormal electrical conditions.

With overall dimensions of 145 × 34 × 140 mm and a weight of 1.129 kg, the module is designed for industrial control cabinets requiring dependable power distribution and long-term operational reliability.


Product Identification

Parameter Specification
Manufacturer GE
Product Series PACSystems RX3i
Model IC695PSD040
Product Type Universal Backplane Power Supply
Installation Location RX3i Universal Backplane
Primary Function Backplane Power Distribution
Dimensions 145 × 34 × 140 mm
Weight 1.129 kg
Cooling Method Natural Air Convection
Mounting Rack Mounted
Typical Application Industrial PLC Automation

Technical Specifications

Technical Item Specification
Brand GE
Series PACSystems RX3i
Model Number IC695PSD040
Product Category Universal Backplane Power Supply
System Platform RX3i PLC
Function Supplies Regulated Power to Backplane
Installation Rack Mounted
Dimensions 145 × 34 × 140 mm
Weight 1.129 kg
Protection Features Overcurrent, Overvoltage Protection
Cooling Passive Cooling
Maintenance Periodic Preventive Inspection

Working Principle

The IC695PSD040 receives incoming electrical power and converts it into stable DC voltages required by the RX3i backplane. These voltages are distributed through the rack to support the operation of CPUs, communication interfaces, and I/O modules.

The simplified power flow is:

Incoming AC/DC Supply

IC695PSD040 Power Supply

RX3i Universal Backplane

CPU Module

Communication Modules

Digital / Analog I/O Modules

Industrial Field Devices

Reliable backplane power is essential because every module in the RX3i rack depends on the power supply for normal operation.


Main Functions

Backplane Power Supply

Provides stable operating voltage for the complete RX3i rack.


System Stability

Maintains continuous power for controllers and expansion modules during normal industrial operation.


Electrical Protection

Internal protection circuitry helps minimize the effects of abnormal electrical conditions.


Reliable Power Distribution

Ensures all compatible modules receive regulated power through the RX3i backplane.


Typical Industrial Applications

The GE IC695PSD040 is suitable for numerous industrial automation environments, including:

Manufacturing Automation

  • Automated production lines
  • Assembly equipment
  • Packaging machinery
  • Robotics

Power Generation

  • Generator auxiliary control
  • Turbine monitoring
  • Power plant automation

Oil & Gas

  • Compressor stations
  • Pipeline monitoring
  • Pump control
  • Process automation

Water Treatment

  • Water distribution
  • Pump stations
  • Wastewater treatment
  • Filtration systems

Chemical Processing

  • Batch control
  • Process monitoring
  • Distributed automation systems

Installation Guide

1. Confirm System Compatibility

Before installation verify:

  • RX3i rack configuration
  • Power supply model
  • Controller compatibility
  • Total system power requirements
  • Installation slot

Only install the module in compatible PACSystems RX3i systems.


2. Shut Down the System

Before servicing:

  1. Stop the PLC.
  2. Disconnect incoming power.
  3. Lock out the electrical supply.
  4. Verify the absence of voltage.
  5. Follow plant safety procedures.

Never insert or remove the module while power is applied.


3. Inspect the Backplane

Check the backplane for:

  • Bent connectors
  • Damaged terminals
  • Loose hardware
  • Dust accumulation
  • Corrosion
  • Moisture

Any physical damage should be corrected before installation.


4. Inspect the Power Supply

Before installation inspect:

  • Housing
  • Connectors
  • Mounting clips
  • Labels
  • Cooling surfaces

Do not install a physically damaged module.


5. Install the Module

Align the IC695PSD040 with the designated power supply position.

Carefully slide the module into the backplane until fully seated.

Verify:

  • Connector engagement
  • Correct alignment
  • Secure mounting
  • Locking mechanism engaged

Avoid forcing the module into position.


6. Connect Input Power

Complete field wiring according to the applicable electrical drawings.

Inspect:

  • Power terminals
  • Ground connection
  • Cable routing
  • Tightness of wiring
  • Correct supply voltage

Proper grounding is essential for reliable operation.


7. Restore System Power

After completing installation:

  1. Verify all wiring.
  2. Confirm module installation.
  3. Restore electrical power.
  4. Observe power indicators.
  5. Allow the PLC to complete startup.

8. Functional Verification

After startup verify:

  • CPU operates normally
  • Communication modules initialize
  • I/O modules become operational
  • Diagnostic indicators show normal status
  • No controller alarms are present

Commissioning Checklist

Following installation confirm:

  • Stable backplane power
  • Normal controller startup
  • Successful communication initialization
  • Correct I/O operation
  • Stable operating voltage
  • Normal cabinet temperature
  • No unexpected system resets

Troubleshooting Guide

Power LED Does Not Illuminate

Possible causes include:

  • No incoming supply
  • Incorrect wiring
  • Open circuit protection device
  • Failed power supply
  • Loose connections

Verify the incoming electrical supply before replacing the module.


CPU Will Not Start

Possible causes:

  • No backplane power
  • Incorrect module installation
  • Controller fault
  • Damaged backplane
  • Power supply malfunction

Confirm the power module is fully seated and properly powered.


Backplane Power Alarm

Possible causes include:

  • Module overload
  • Internal power supply fault
  • Backplane short circuit
  • Excessive current demand
  • Hardware incompatibility

Inspect system loading before replacing components.


Unexpected PLC Restart

Possible causes:

  • Power interruptions
  • Loose terminals
  • Unstable supply voltage
  • Overheating
  • Failing power module

Inspect power quality and electrical connections.


Communication Failure

Possible causes:

  • Backplane power instability
  • Controller startup failure
  • Communication module fault
  • Loose modules

Verify stable backplane power before troubleshooting network hardware.


Excessive Temperature

Possible causes:

  • Restricted ventilation
  • High ambient temperature
  • Cabinet contamination
  • Excessive electrical loading

Maintain sufficient airflow inside the enclosure.


Diagnostic Fault Indication

Possible causes:

  • Internal module fault
  • Controller diagnostic error
  • Configuration problem
  • Backplane communication issue

Review PLC diagnostics before replacing hardware.


Preventive Maintenance

Monthly Inspection

Check:

  • LED indicators
  • Power terminals
  • Cabinet cleanliness
  • Module mounting

Quarterly Inspection

Inspect:

  • Grounding
  • Cable condition
  • Backplane connectors
  • Ventilation openings

Annual Maintenance

Perform:

  • Cabinet cleaning
  • Functional testing
  • Electrical connection inspection
  • Power quality verification
  • Complete PLC diagnostics

Maintenance Checklist

Inspection Item Status
Incoming Power Verified
Module Housing Inspected
Wiring Checked
Ground Connection Verified
Backplane Connector Inspected
Module Fully Installed
CPU Running Normally
Communication Verified
I/O Operational
Diagnostic LEDs Normal

Compatible RX3i Components

The IC695PSD040 is designed for operation with compatible RX3i hardware.

Component Function
RX3i CPU Module Central Controller
Ethernet Module Industrial Networking
Serial Communication Module Device Communication
Digital Input Module Signal Acquisition
Digital Output Module Equipment Control
Analog Input Module Process Measurement
Analog Output Module Analog Control
Universal Backplane Module Interconnection

Actual compatibility depends on the complete RX3i system configuration.


Key Advantages

Stable Backplane Power

Provides continuous regulated power for RX3i controllers and expansion modules.

Compact Rack Design

The module dimensions of 145 × 34 × 140 mm allow efficient installation within standard industrial control cabinets.

Industrial-Grade Reliability

Designed for continuous operation in demanding factory environments.

Easy Maintenance

The modular design simplifies replacement and preventive maintenance.

Enhanced System Protection

Integrated electrical protection helps improve system reliability under abnormal operating conditions.


Frequently Asked Questions

What is the GE IC695PSD040?

The IC695PSD040 is an RX3i Universal Backplane Power Supply designed to provide operating power for PACSystems RX3i automation systems.

What are its dimensions?

The module measures:

145 × 34 × 140 mm

What is its weight?

The module weighs approximately:

1.129 kg

What is the primary function of this module?

It supplies regulated power to the RX3i universal backplane, supporting CPUs, communication modules, and I/O modules.

Can it be replaced while the controller is powered?

No. Power should always be disconnected before installing or removing the module.

What symptoms may indicate a power supply problem?

Typical symptoms include:

  • Power LED off
  • CPU startup failure
  • Backplane alarms
  • Communication faults
  • Unexpected PLC resets

What should be inspected before replacing the power supply?

Verify incoming power, wiring, grounding, module installation, controller diagnostics, and backplane condition before replacing the module.

How can the service life be extended?

Maintain a clean enclosure, ensure proper ventilation, inspect electrical connections regularly, and provide a stable incoming power source.


Installation Checklist

Item Status
Correct Module Verified
System Power Isolated
Backplane Inspected
Module Inspected
Module Installed
Wiring Verified
Ground Connected
System Power Restored
CPU Started Successfully
I/O Modules Operating
Diagnostics Normal
Final Functional Test Completed

Conclusion

The GE IC695PSD040 RX3i Universal Backplane Power Supply is a key infrastructure component within the PACSystems RX3i automation platform. By supplying stable power to the backplane, it enables reliable operation of CPUs, communication interfaces, and I/O modules throughout the control system.

With compact dimensions of 145 × 34 × 140 mm and a weight of 1.129 kg, the module is well suited for industrial control cabinets where dependable performance and easy maintenance are essential. Proper installation, secure wiring, adequate grounding, and routine preventive inspections are critical to maintaining long-term system reliability.

During troubleshooting, technicians should verify incoming power quality, wiring integrity, module seating, backplane condition, and controller diagnostics before concluding that the power supply requires replacement. When installed and maintained correctly, the IC695PSD040 delivers dependable power distribution for demanding RX3i automation applications.