• Schneider ATS480C48Y Soft Starter
  • Schneider ATS480C48Y Soft Starter
  • Schneider ATS480C48Y Soft Starter
  • Schneider ATS480C48Y Soft Starter
Product Overview The Schneider ATS480C48Y Soft Starter is a heavy-duty industrial motor starter designed to provide smooth acceleration and controlled deceleration for large three-phase asynchronous mot……
Schneider ATS480C48Y Soft Starter
  • Schneider
  • ATS480C48Y
  • Soft Starter
  • France
  • 670 x 400 x 314 mm
  • 51.4 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 19

Our advantage

Schneider ATS480C48Y Soft Starter

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider ATS480C48Y Soft Starter

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider ATS480C48Y Soft Starter

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider ATS480C48Y Soft Starter

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider ATS480C48Y Soft Starter is a heavy-duty industrial motor starter designed to provide smooth acceleration and controlled deceleration for large three-phase asynchronous motors. As a member of the Altivar ATS480 series, it incorporates advanced SCR (Silicon Controlled Rectifier) technology to reduce motor inrush current, minimize mechanical shock, and improve the reliability of industrial motor-driven systems.

Compared with conventional direct-on-line (DOL) starting, the ATS480C48Y gradually increases motor voltage during startup, significantly reducing stress on motors, gearboxes, shafts, belts, pumps, compressors, and other rotating equipment. During stopping, its controlled deceleration function minimizes water hammer in pumping systems and reduces mechanical wear on transmission components.

The ATS480C48Y is widely used in industries such as water treatment, mining, oil & gas, chemical processing, cement manufacturing, HVAC, steel production, paper mills, and large industrial automation systems.

The supplied product information identifies the Schneider ATS480C48Y Soft Starter with overall dimensions of 670 × 400 × 314 mm and a weight of 51.4 kg.


Product Information

  • Manufacturer: Schneider Electric
  • Model: ATS480C48Y
  • Product Type: Soft Starter
  • Dimensions: 670 × 400 × 314 mm
  • Weight: 51.4 kg
  • Motor Type: Three-Phase AC Induction Motor
  • Installation: Industrial Control Cabinet / Motor Control Center (MCC)
  • Cooling Method: Forced Air Cooling
  • Control Technology: SCR Phase Angle Control
  • Primary Function: Soft Starting and Soft Stopping of Industrial Motors

Technical Specifications

Parameter Specification
Manufacturer Schneider Electric
Model ATS480C48Y
Product Type Soft Starter
Dimensions 670 × 400 × 314 mm
Weight 51.4 kg
Motor Type Three-Phase AC Motor
Starting Method Voltage Ramp Soft Start
Stop Method Soft Stop
Mounting Method Panel Mount
Installation Location Industrial Control Cabinet
Cooling Forced Air Ventilation
Application Heavy Industrial Motor Control

Function and Working Principle

The ATS480C48Y controls motor acceleration by adjusting the firing angle of internal SCR power devices.

Typical operating sequence:

Incoming Three-Phase Power

ATS480C48Y Soft Starter

Industrial Motor

Mechanical Equipment

Rated Speed Operation

Instead of applying full voltage instantly, the ATS480C48Y gradually increases the voltage delivered to the motor.

This provides:

  • Reduced starting current
  • Lower mechanical stress
  • Stable acceleration
  • Reduced voltage dips
  • Improved equipment protection
  • Extended motor service life

During shutdown, the voltage is reduced gradually to allow controlled motor deceleration.


Main Functions

The ATS480C48Y provides:

  • Soft motor starting
  • Soft motor stopping
  • Adjustable current limitation
  • Motor protection
  • Torque control
  • Mechanical stress reduction
  • Reduced maintenance requirements
  • Stable production startup
  • Improved process reliability
  • Equipment life extension

Typical Industrial Applications

The ATS480C48Y is suitable for:

  • Water treatment facilities
  • Wastewater pumping stations
  • Air compressor systems
  • Industrial ventilation systems
  • Cooling tower fans
  • Conveyor systems
  • Crushers
  • Mixers
  • Cement production lines
  • Mining operations
  • Oil & gas facilities
  • Chemical processing plants
  • Steel mills
  • Paper manufacturing
  • Large industrial automation systems

Benefits of Soft Starting

Compared with traditional motor starters, the ATS480C48Y offers:

  • Reduced motor starting current
  • Lower electrical network disturbances
  • Less mechanical shock
  • Longer bearing life
  • Reduced gearbox wear
  • Improved coupling protection
  • Lower maintenance costs
  • Reduced downtime
  • Increased operational reliability
  • Improved production efficiency

Installation Guide

Step 1 – Verify Equipment

Before installation, verify:

  • Schneider ATS480C48Y
  • Motor power rating
  • Supply voltage
  • Control cabinet dimensions
  • Application compatibility

Inspect the unit carefully for shipping damage.


Step 2 – Disconnect Power

Before wiring:

  1. Disconnect incoming power.
  2. Apply lockout/tagout procedures.
  3. Verify zero voltage.
  4. Isolate the motor circuit.
  5. Wear appropriate PPE.

Never install or service the equipment while energized.


Step 3 – Select Installation Location

Install the ATS480C48Y inside a clean, well-ventilated industrial control cabinet.

Avoid locations exposed to:

  • Water
  • Excessive dust
  • Corrosive gases
  • Oil mist
  • High vibration
  • Direct sunlight
  • High ambient temperatures

Provide adequate clearance for airflow and maintenance access.


Step 4 – Mount the Soft Starter

Secure the soft starter firmly to the mounting panel.

Verify:

  • Correct mounting orientation
  • Stable installation
  • Adequate cooling clearance
  • Accessible terminals
  • Proper cable routing

Step 5 – Connect the Power Circuit

Connect:

  • Three-phase input supply
  • Motor output terminals
  • Protective earth (PE)

Inspect:

  • Cable sizing
  • Terminal torque
  • Phase sequence
  • Cable insulation
  • Ground continuity

Step 6 – Connect the Control Circuit

Wire the required control terminals, including:

  • Start command
  • Stop command
  • Reset input
  • Fault relay
  • Status outputs
  • External interlocks

Keep control cables separated from power cables to minimize electrical interference.


Step 7 – Configure Operating Parameters

Configure parameters according to the motor and application requirements.

Typical settings include:

  • Initial voltage
  • Acceleration time
  • Deceleration time
  • Current limit
  • Motor protection
  • Stop mode

Proper parameter adjustment improves starting performance and protects both the motor and driven equipment.


Step 8 – Final Inspection

Before energizing:

Inspect:

  • Power wiring
  • Control wiring
  • Grounding
  • Terminal tightness
  • Cooling airflow
  • Mounting hardware
  • Cable routing

Correct all issues before startup.


Commissioning Procedure

After installation:

  1. Restore power.
  2. Observe status indicators.
  3. Start the motor.
  4. Monitor motor current.
  5. Verify smooth acceleration.
  6. Check motor speed.
  7. Observe equipment vibration.
  8. Test soft stopping.
  9. Confirm stable operation.
  10. Record commissioning data.

Preventive Maintenance

Routine maintenance should include:

  • Tightening power terminals
  • Inspecting control wiring
  • Cleaning cooling fans
  • Removing cabinet dust
  • Inspecting air passages
  • Checking grounding
  • Verifying mounting hardware
  • Monitoring operating temperature
  • Reviewing fault history
  • Recording maintenance activities

Troubleshooting Guide

Problem 1 – Soft Starter Does Not Power Up

Possible causes:

  • No input power
  • Blown fuse
  • Loose wiring
  • Control power failure
  • Internal electronic fault

Diagnostic Procedure

  1. Measure input voltage.
  2. Check protective devices.
  3. Inspect wiring connections.
  4. Verify control power.
  5. Observe indicator LEDs.

Problem 2 – Motor Does Not Start

Possible causes:

  • Missing start command
  • Incorrect wiring
  • Incorrect parameter settings
  • Motor overload
  • Safety interlock active

Verify all electrical and control connections before replacing equipment.


Problem 3 – High Starting Current

Possible causes:

  • Short acceleration time
  • Current limit improperly configured
  • Heavy mechanical load
  • Motor fault
  • Power supply issues

Review parameter settings before changing hardware.


Problem 4 – Slow Motor Acceleration

Possible causes:

  • Low starting voltage
  • Long ramp time
  • Excessive load
  • Mechanical resistance
  • Incorrect configuration

Inspect both electrical settings and mechanical equipment.


Problem 5 – Soft Starter Trips During Startup

Possible causes:

  • Overload
  • Phase loss
  • Wiring errors
  • Motor short circuit
  • Protection settings

Determine the root cause before restarting.


Problem 6 – Overheating

Possible causes:

  • Cooling fan malfunction
  • Blocked ventilation
  • Dust accumulation
  • High ambient temperature
  • Continuous overload

Inspect the cooling system thoroughly.


Problem 7 – Excessive Motor Vibration

Possible causes:

  • Mechanical imbalance
  • Misalignment
  • Loose coupling
  • Bearing wear
  • Improper acceleration settings

Inspect the complete drive train.


Problem 8 – Motor Does Not Stop Smoothly

Possible causes:

  • Incorrect stop parameters
  • High inertia load
  • Control signal issues
  • Mechanical resistance

Adjust deceleration parameters according to the application.


Problem 9 – Frequent Fault Alarms

Possible causes:

  • Voltage instability
  • Overload
  • Loose wiring
  • Environmental issues
  • Incorrect configuration

Review fault logs and operating conditions.


Problem 10 – Communication or Control Failure

Possible causes:

  • Loose control wiring
  • PLC communication problems
  • Electrical noise
  • Incorrect terminal assignment

Inspect the entire control system before replacing components.


Fault Diagnosis Flow

Recommended troubleshooting sequence:

Incoming Power

Protection Devices

ATS480C48Y Soft Starter

Control Signals

Motor Wiring

Motor

Mechanical Equipment

Normal Operation

A systematic diagnostic approach minimizes downtime and unnecessary component replacement.


Replacement Procedure

Preparation

  1. Disconnect power.
  2. Apply lockout/tagout.
  3. Verify zero voltage.
  4. Label all cables.
  5. Prepare replacement equipment.

Removal

  1. Disconnect power cables.
  2. Disconnect control wiring.
  3. Remove mounting hardware.
  4. Carefully remove the ATS480C48Y.

Installation

  1. Install the replacement unit.
  2. Connect power wiring.
  3. Connect control wiring.
  4. Verify grounding.
  5. Tighten terminals.
  6. Inspect cable routing.

Functional Test

  1. Restore power.
  2. Verify indicators.
  3. Start the motor.
  4. Observe acceleration.
  5. Monitor current.
  6. Test stopping performance.
  7. Confirm stable operation.

Preventive Maintenance Schedule

Maintenance Item Recommended Action
Power Terminals Inspect and tighten
Control Wiring Check connections
Cooling Fans Clean and inspect
Air Passages Remove dust
Ground Connection Verify continuity
Indicator LEDs Monitor status
Mounting Hardware Inspect security
Operating Temperature Monitor regularly
Motor Current Observe during operation
Maintenance Records Update after servicing

Common Installation Mistakes

Incorrect Cable Sizing

Improper cable selection may result in overheating and voltage drop.

Loose Connections

Loose terminals can cause overheating and intermittent faults.

Poor Cooling

Restricted airflow reduces cooling efficiency and equipment reliability.

Incorrect Parameter Settings

Improper acceleration or current limit values may prevent successful startup.

Insufficient Grounding

Poor grounding increases electrical interference and safety risks.

Mixing Power and Control Cables

Separate cable routing helps reduce electrical noise.

Ignoring Environmental Conditions

Dust, moisture, and excessive temperatures can reduce equipment life.


Key Advantages

  • Heavy-duty industrial soft starter
  • Smooth motor acceleration and deceleration
  • Reduced starting current
  • Lower mechanical stress
  • Enhanced motor protection
  • Improved process reliability
  • Suitable for large industrial motors
  • Compact cabinet installation
  • Dimensions: 670 × 400 × 314 mm
  • Weight: 51.4 kg

Technical FAQs

What is the Schneider ATS480C48Y?

It is a high-capacity soft starter designed for controlled starting and stopping of three-phase AC induction motors.

What are its dimensions?

The supplied dimensions are 670 × 400 × 314 mm.

What is its weight?

The supplied weight is 51.4 kg.

What is the primary function of the ATS480C48Y?

It reduces motor starting current while providing smooth acceleration and deceleration, protecting both electrical and mechanical equipment.

Why is the starting current reduced?

SCR technology gradually increases motor voltage, limiting inrush current during startup.

Why does the soft starter trip during startup?

Possible causes include overload, wiring faults, phase loss, incorrect parameter settings, or motor faults.

Why is the unit overheating?

Common causes include blocked ventilation, cooling fan failure, overload conditions, high ambient temperature, or dust accumulation.

What maintenance is recommended?

Routine inspection of terminals, cooling systems, wiring, grounding, ventilation, and operating status helps ensure long-term reliability.

Which applications are suitable?

The ATS480C48Y is suitable for pumps, compressors, conveyors, fans, crushers, mixers, and many other heavy-duty industrial motor applications.


Conclusion

The Schneider ATS480C48Y Soft Starter is engineered to deliver reliable and efficient motor control for demanding industrial applications. By limiting inrush current and reducing mechanical stress, it helps extend equipment life, improve process stability, and lower maintenance costs.

With dimensions of 670 × 400 × 314 mm and a weight of 51.4 kg, the ATS480C48Y is well suited for installation in industrial control cabinets and motor control centers. Proper installation, parameter optimization, routine preventive maintenance, and systematic troubleshooting ensure dependable operation and maximize the performance of industrial motor-driven systems.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501