• GE UR 6UH Multilin UR Series Digital I/O Module
  • GE UR 6UH Multilin UR Series Digital I/O Module
  • GE UR 6UH Multilin UR Series Digital I/O Module
  • GE UR 6UH Multilin UR Series Digital I/O Module
Product Overview The GE UR 6UH Multilin UR Series Digital I/O Module is a digital I/O interface component used with compatible GE Multilin UR Series protection and control devices. It provides the conne……
GE UR 6UH Multilin UR Series Digital I/O Module
  • GE
  • UR 6UH
  • Digital I/O Module
  • USA
  • 120 × 30 × 100 mm
  • 0.87 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 18

Our advantage

GE UR 6UH Multilin UR Series Digital I/O Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE UR 6UH Multilin UR Series Digital I/O Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE UR 6UH Multilin UR Series Digital I/O Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE UR 6UH Multilin UR Series Digital I/O Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE UR 6UH Multilin UR Series Digital I/O Module is a digital I/O interface component used with compatible GE Multilin UR Series protection and control devices. It provides the connection point between external discrete signals and the relay’s internal processing system, allowing field equipment conditions to participate in configured protection and automation functions.

Within an electrical protection system, many operational decisions depend on digital status information such as breaker position, auxiliary contact states, equipment alarms, permissive signals, and interlocking conditions. The UR 6UH enables these discrete signals to be integrated into the overall relay control architecture.

The module operates as part of the UR Series hardware platform and relies on the host relay configuration, assigned I/O functions, and connected field circuits. It does not independently execute protection algorithms but supports the signal exchange required by the relay system.

For maintenance applications, the UR 6UH should be evaluated together with connected wiring, external devices, and relay configuration. Proper identification of the original signal assignment is important before replacement to avoid incorrect integration into the existing protection scheme.


Technical Specifications

Parameter Specification
Manufacturer GE
Model UR 6UH
Product Family Multilin UR Series
Product Type Digital I/O Module
Primary Function Digital Signal Interface
System Role Discrete I/O
Application Protection and Control Systems
Installation GE Multilin UR Series Devices
Dimensions 120 × 30 × 100 mm
Weight 0.87 kg

Product Features

The UR 6UH is designed for digital signal integration within compatible GE Multilin UR Series equipment.

Key characteristics include:

  • GE Multilin UR Series digital I/O module
  • Model UR 6UH
  • Provides discrete signal interfacing
  • Supports external equipment status monitoring
  • Integrates field signals with relay logic
  • Suitable for breaker and switchgear applications
  • Supports alarm and interlock signal processing
  • Works with configured UR Series automation functions
  • Compatible with established protection system architectures
  • Suitable for maintenance and replacement projects

The final function of each I/O point depends on the host relay configuration and the connected external circuits.


Working Principle

The UR 6UH works as an interface between external discrete devices and the processing unit of a GE Multilin UR Series relay.

A simplified signal path is:

External Equipment → UR 6UH → UR Series Processor → Protection / Control Logic → System Response

When an external contact or device changes state, the corresponding digital signal is transferred through the I/O module to the relay processor. The processor evaluates the received condition according to the configured application logic.

Depending on the programmed settings, the relay can use the signal for status indication, alarm generation, control permission, blocking functions, or equipment interlocking.

The module therefore provides the hardware connection required for communication between physical electrical equipment and the programmable functions inside the UR Series protection system.


Role in a Multilin UR Protection Architecture

The UR 6UH belongs to the digital signal interface layer of the GE Multilin UR Series architecture.

A typical signal flow can be represented as:

Field Devices → UR 6UH Digital I/O → UR Processor → Protection Logic → Control Equipment

System Layer Typical Function
Field Devices Provide equipment status and control signals
Digital I/O Layer Transfers discrete conditions
Processing Layer Evaluates signal states
Protection Layer Executes protection functions
Automation Layer Handles control sequences and interlocks
Control Layer Sends commands to external equipment
Supervisory Layer Provides monitoring information

The digital I/O layer allows the relay to respond not only to electrical measurements but also to real-world equipment conditions.

For example, breaker auxiliary contacts can provide confirmation of equipment position, allowing the relay logic to determine whether a control operation should proceed.


Industrial Applications

The UR 6UH is suitable for industrial and utility protection systems using compatible GE Multilin UR Series equipment.

Application Typical Use
Electrical Substations Breaker status and control monitoring
Power Generation Generator protection interfaces
Distribution Networks Feeder equipment monitoring
Transmission Systems Protection interlocking
Motor Control Systems Auxiliary status monitoring
Transformer Protection Alarm and control signals
Industrial Power Plants Equipment coordination
Utility Automation Discrete signal processing

The actual application depends on the selected UR Series relay and the configured protection strategy.


Installation and Maintenance

The UR 6UH should be installed according to the specific configuration of the host UR Series relay. Because digital I/O circuits are directly connected to external equipment, accurate wiring identification is essential during replacement.

Recommended maintenance checks include:

  • Confirm the complete UR 6UH model.
  • Identify the installed UR Series relay.
  • Verify module compatibility.
  • Record the existing module position.
  • Document I/O signal assignments.
  • Identify connected field equipment.
  • Record alarm and interlock wiring.
  • Isolate related circuits before replacement.
  • Inspect connectors and terminals.
  • Check field wiring condition.
  • Verify correct module installation.
  • Ensure connectors are properly seated.
  • Restore wiring according to the original configuration.
  • Confirm digital signal operation.
  • Check relay diagnostic information.
  • Verify system response under normal conditions.

If a digital signal remains incorrect after replacement, technicians should inspect the complete circuit path, including field contacts, wiring, control voltage, configuration settings, and connected equipment.


Related Components

The UR 6UH operates within a complete GE Multilin UR Series protection and control system.

Component Function
UR Series Protection Relay Executes protection and control functions
UR 6UH Provides digital I/O interface
UR 6TH Provides digital I/O functions
UR 6LH Provides digital I/O functions
UR 6DV Provides digital I/O functions
UR 6DH Provides digital I/O functions
UR 6CV Provides digital I/O functions
UR 6CH Provides digital I/O functions
UR 6AH Provides digital I/O combination functions
UR 5CH Handles transducer-related interfaces
UR 1HH Provides relay power supply

Selection between different UR Series modules should be based on required signal functions and the host relay configuration.


Recommended Related Models

Model / Product Family Product Type Typical Application
GE UR 6UH Digital I/O Module Discrete signal interfacing
GE UR 6TH Digital I/O Module Digital signal interface
GE UR 6LH Digital I/O Module Digital signal interface
GE UR 6DV Digital I/O Module Digital signal interface
GE UR 6DH Digital I/O Module Digital signal interface
GE UR 6CV Digital I/O Module Digital signal interface
GE UR 6AH Digital I/O Combination Module Digital status and control
GE UR 5CH Transducer I/O Module Analog-related signal interface

Although these modules are part of the same UR Series family, each model has different application characteristics and should be selected according to the required system function.


Key Advantages

  • GE Multilin UR Series digital I/O hardware
  • Model UR 6UH
  • Provides discrete signal interfacing
  • Connects external equipment with relay logic
  • Supports equipment status monitoring
  • Suitable for breaker and switchgear applications
  • Supports alarm and interlock functions
  • Integrates with configured protection and automation logic
  • Suitable for utility and industrial power systems
  • Useful for maintenance and replacement applications

Technical FAQs

How is the UR 6UH used in a GE Multilin UR Series system?

The UR 6UH provides the digital signal interface required for transferring external equipment conditions into the UR Series relay architecture. These signals can then be used by configured protection, monitoring, and automation functions.

What external devices are commonly connected through digital I/O modules?

Typical connections include breaker auxiliary contacts, switch status signals, alarm contacts, interlock circuits, and other binary devices used for equipment monitoring and control.

What information should be confirmed before replacing a UR 6UH module?

The host relay model, module position, existing I/O assignments, field wiring connections, and configured logic functions should be verified before replacement to maintain the original system operation.

Why should a digital I/O fault be checked from the entire signal path?

A digital signal depends on multiple components, including the external contact, wiring, control voltage, terminals, connectors, module, and relay configuration. A fault in any section can create similar symptoms at the relay side.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501