The GE UR 6LH Multilin UR Series Digital I/O Module is a digital I/O component used within compatible GE Multilin UR Series protection and control equipment. It forms part of the discrete signal interface between external electrical equipment and the relay’s internal processing architecture.
In a protection and automation system, many operating decisions depend on binary information rather than measured analog values alone. Breaker position, auxiliary contacts, switch states, alarms, permissive signals, and interlocks can all be incorporated into the relay’s control logic through digital I/O.
The UR 6LH works together with the host UR Series relay, processor, protection functions, and configured automation logic. Its application is therefore determined by the specific relay architecture and I/O assignment rather than by the module operating independently.
For maintenance engineers, the module is particularly relevant when troubleshooting or replacing discrete signal hardware in an established Multilin UR installation. The connected field circuits should be checked together with the module to identify the actual source of an I/O fault.
| Parameter | Specification |
|---|---|
| Manufacturer | GE |
| Model | UR 6LH |
| Product Family | Multilin UR Series |
| Product Type | Digital I/O Module |
| Primary Function | Digital Signal Interface |
| System Role | Discrete I/O |
| Application | Protection and Control Systems |
| Installation | GE Multilin UR Series Devices |
| Dimensions | 120 × 30 × 100 mm |
| Weight | 1.36 kg |
The UR 6LH is intended for digital signal interfacing within compatible GE Multilin UR Series equipment.
Key characteristics include:
The specific I/O assignment should be determined from the host relay configuration and the external circuits connected to the module.
The UR 6LH forms part of the discrete signal path between external equipment and the processing architecture of a Multilin UR Series relay.
A simplified relationship can be represented as:
External Equipment → UR 6LH → UR Series Processor → Protection / Control Logic → External Control Circuit
When an external device changes state, the applicable digital I/O circuit transfers that binary condition into the relay system. The processor can evaluate the information together with protection elements, alarms, permissive conditions, and interlocks.
The configured logic can then use the resulting status to determine whether a particular control action, alarm, blocking function, or interlocking condition should occur.
This makes the UR 6LH part of the connection between physical equipment conditions and the programmable functions of the protection relay.
The UR 6LH occupies the digital I/O interface layer within a Multilin UR Series protection system.
A simplified architecture is:
Field Equipment → UR 6LH → UR Processor → Protection / Automation Logic → External Control Equipment
| System Layer | Typical Function |
|---|---|
| Field Equipment | Provides equipment status and discrete conditions |
| Digital I/O Layer | Exchanges binary signals |
| Processing Layer | Evaluates incoming conditions |
| Protection Layer | Executes configured protection functions |
| Automation Layer | Handles control and interlocking |
| Output Layer | Transfers commands to external circuits |
| Supervisory Layer | Monitors relay status and events |
This architecture allows the relay to combine electrical protection with equipment status and control information.
For example, a breaker auxiliary signal can be used to confirm equipment position before a control sequence is permitted. Similarly, an external alarm or interlock can become part of the relay’s configured operating logic.
The UR 6LH is suitable for electrical protection and automation installations using compatible GE Multilin UR Series equipment.
| Application | Typical Use |
|---|---|
| Electrical Substations | Breaker and switchgear status monitoring |
| Power Generation | Generator control interfaces |
| Distribution Systems | Feeder equipment monitoring |
| Transmission Systems | Protection interlocking |
| Motor Protection | Contactor and auxiliary signals |
| Transformer Protection | Alarm and control circuits |
| Industrial Power Systems | Equipment interlocks |
| Utility Automation | Discrete monitoring and control |
The actual application depends on the host relay model, I/O configuration, and connected field equipment.
Before installing or replacing a UR 6LH, the existing relay configuration should be reviewed carefully. Digital I/O circuits are directly associated with external control and monitoring circuits, so accurate identification of the existing wiring is important.
Recommended checks include:
If a digital input or output does not behave as expected after replacement, the complete circuit should be traced. Control voltage, external contacts, field wiring, terminals, configuration, and connected equipment can all affect the final I/O condition.
The UR 6LH operates as part of a broader Multilin UR Series protection and control architecture.
| Component | Function |
|---|---|
| UR Series Protection Relay | Provides protection and control functions |
| UR 6LH | Provides digital I/O interfacing |
| UR 6DV | Provides digital I/O functions |
| UR 6DH | Provides digital I/O functions |
| UR 6CV | Provides digital I/O functions |
| UR 6CH | Provides digital I/O functions |
| UR 6AH | Provides digital I/O combination functions |
| UR 5CH | Interfaces transducer-related signals |
| UR 1HH | Provides relay operating power |
| Processor Module | Executes protection and control logic |
| Breaker / Switchgear | Provides status and receives commands |
| Auxiliary Contacts | Supply equipment position signals |
The correct module should be selected according to the required I/O function and compatibility with the host relay.
For GE Multilin UR Series installations, related models can be considered according to their individual system roles.
| Model / Product Family | Product Type | Typical Application |
|---|---|---|
| GE UR 6LH | Digital I/O Module | Discrete signal interfacing |
| GE UR 6DV | Digital I/O Module | Digital signal interface |
| GE UR 6DH | Digital I/O Module | Digital signal interface |
| GE UR 6CV | Digital I/O Module | Digital signal interface |
| GE UR 6CH | Digital I/O Module | Digital signal interface |
| GE UR 6AH | Digital I/O Combination Module | Digital status and control |
| GE UR 5CH | Transducer I/O Module | Transducer signal interface |
These modules belong to the same Multilin UR product family, but their functions and system compatibility should be verified before substitution or replacement.
The module forms part of the digital I/O path through which compatible external equipment conditions can be transferred to the UR Series relay. The processor can then use these status signals within configured monitoring, protection, alarm, or control functions.
Electrical measurements describe parameters such as current and voltage, while digital signals indicate physical equipment conditions. Combining both allows the relay to make protection and control decisions based on the actual state of the electrical system.
The host relay model, module position, I/O assignments, connected field devices, terminal connections, and associated control circuits should be recorded. This information helps maintain the original signal relationships during replacement.
The signal path should be checked from the external device toward the relay, including auxiliary contacts, control voltage, wiring, terminals, connectors, and module status. Intermittent connection problems can otherwise be mistaken for an electronic module failure.