• GE UR 6DH Multilin UR Series Digital I/O Module
  • GE UR 6DH Multilin UR Series Digital I/O Module
  • GE UR 6DH Multilin UR Series Digital I/O Module
  • GE UR 6DH Multilin UR Series Digital I/O Module
Product Overview The GE UR 6DH Multilin UR Series Digital I/O Module is a digital I/O component used within compatible GE Multilin UR Series protection and control equipment. It provides the physical in……
GE UR 6DH Multilin UR Series Digital I/O Module
  • GE
  • UR 6DH
  • Digital I/O Module
  • USA
  • 120 × 30 × 100 mm
  • 0.9 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 21

Our advantage

GE UR 6DH Multilin UR Series Digital I/O Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

GE UR 6DH Multilin UR Series Digital I/O Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

GE UR 6DH Multilin UR Series Digital I/O Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

GE UR 6DH Multilin UR Series Digital I/O Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The GE UR 6DH Multilin UR Series Digital I/O Module is a digital I/O component used within compatible GE Multilin UR Series protection and control equipment. It provides the physical interface between discrete external signals and the relay’s internal processing architecture.

In a typical protection system, the relay needs to monitor equipment conditions such as breaker position, auxiliary contacts, switch states, alarms, and interlocks. Digital I/O hardware allows these binary conditions to become part of the relay’s configured protection and automation logic.

The UR 6DH works as part of the host relay rather than functioning as an independent controller. Its application depends on the specific UR Series device, I/O configuration, field wiring, and control requirements.

For maintenance applications, the existing module position and signal assignments should be recorded before replacement. This is particularly useful when the relay has been operating for an extended period and its original wiring has been modified or expanded.


Technical Specifications

Parameter Specification
Manufacturer GE
Model UR 6DH
Product Family Multilin UR Series
Product Type Digital I/O Module
Primary Function Digital Signal Interface
System Role Discrete I/O
Application Protection and Control Systems
Installation GE Multilin UR Series Devices
Dimensions 120 × 30 × 100 mm
Weight 0.9 kg

Product Features

The UR 6DH is intended for discrete signal interfacing within compatible GE Multilin UR Series equipment.

Key characteristics include:

  • GE Multilin UR Series digital I/O module
  • Model UR 6DH
  • Provides discrete signal interfacing
  • Connects external equipment with relay functions
  • Supports equipment status monitoring
  • Suitable for breaker and switchgear applications
  • Supports alarm and interlock circuits
  • Integrates with configured relay logic
  • Works within the UR Series I/O architecture
  • Suitable for maintenance and replacement applications

The actual function of the I/O points depends on the host relay configuration and the external circuits connected to the module.


Working Principle

The UR 6DH forms part of the discrete signal path between external equipment and the processing system of a Multilin UR Series relay.

A simplified relationship is:

External Equipment → UR 6DH → UR Series Processor → Protection / Control Logic → External Control Circuit

Binary conditions from external equipment are transferred through the applicable digital I/O circuits to the relay’s processing system. The processor can evaluate these conditions alongside protection elements, alarms, interlocks, and other configured logic.

When a defined condition is met, the relay’s control logic can initiate the corresponding response through the configured control architecture.

This arrangement allows physical equipment states to interact with programmable protection and automation functions without requiring a separate control system for every discrete signal.


Role in a Multilin UR Protection Architecture

The UR 6DH occupies the digital I/O interface layer within the Multilin UR Series architecture.

A simplified control path can be viewed as:

Field Equipment → Digital I/O → UR Processor → Protection / Automation Logic → Control Equipment

System Layer Typical Function
Field Equipment Provides equipment status and discrete conditions
Digital I/O Layer Exchanges binary signals
Processing Layer Evaluates incoming conditions
Protection Layer Executes configured protection functions
Automation Layer Handles control and interlocking
Output Layer Transfers commands to external circuits
Supervisory Layer Monitors relay status and events

The digital I/O layer allows external equipment information to be incorporated into the relay’s overall protection strategy.

For example, equipment status can be used as an input to an interlock or control sequence, allowing the relay to determine whether a particular operation should be permitted.


Industrial Applications

The UR 6DH can be used in protection and automation installations based on compatible GE Multilin UR Series equipment.

Application Typical Use
Electrical Substations Switchgear status monitoring
Power Generation Generator control interfaces
Distribution Systems Feeder equipment monitoring
Transmission Systems Protection interlocking
Motor Protection Contactor and auxiliary signals
Transformer Protection Alarm and control circuits
Industrial Power Systems Equipment interlocks
Utility Automation Discrete monitoring and control

The actual application depends on the host relay model, I/O configuration, and connected electrical equipment.


Installation and Maintenance

Before replacing a UR 6DH, technicians should identify the host relay and document the existing I/O configuration. This helps prevent incorrect wiring or signal assignment during maintenance.

Recommended checks include:

  • Confirm the complete UR 6DH model.
  • Identify the host Multilin UR Series relay.
  • Verify module compatibility.
  • Record the module position.
  • Document digital signal assignments.
  • Identify connected equipment.
  • Record breaker, switch, alarm, and interlock circuits.
  • Isolate the relevant control circuits before replacement.
  • Inspect connectors and terminals.
  • Check field wiring for damage or loose connections.
  • Verify correct module positioning.
  • Ensure connectors are fully seated.
  • Restore system connections according to the applicable procedure.
  • Check expected digital signal states.
  • Verify configured control functions.
  • Review relay diagnostics.
  • Confirm normal operation of associated equipment.

If a digital signal remains abnormal after replacement, the complete circuit should be checked. External contacts, control voltage, wiring, terminal connections, configuration, and downstream equipment can all affect the final signal seen by the relay.


Related Components

The UR 6DH operates as part of a wider Multilin UR Series protection and control architecture.

Component Function
UR Series Protection Relay Provides protection and control functions
UR 6DH Provides digital I/O interfacing
UR 6CV Provides digital I/O functions
UR 6CH Provides digital I/O functions
UR 6AH Provides digital I/O combination functions
UR 5CH Interfaces transducer-related signals
UR 1HH Provides relay operating power
Processor Module Executes protection and control logic
Breaker / Switchgear Provides status and receives commands
Auxiliary Contacts Supply equipment position signals
Communication Interface Connects the relay with supervisory systems

The appropriate module should be selected according to the required I/O function and compatibility with the host relay.


Recommended Related Models

For GE Multilin UR Series installations, related models can be considered according to their specific system roles.

Model / Product Family Product Type Typical Application
GE UR 6DH Digital I/O Module Discrete signal interfacing
GE UR 6CV Digital I/O Module Digital signal interface
GE UR 6CH Digital I/O Module Digital signal interface
GE UR 6AH Digital I/O Combination Module Digital status and control
GE UR 5CH Transducer I/O Module Transducer signal interface
GE UR 1HH Power Supply Module Relay power infrastructure

These modules may serve different functions within the UR Series architecture. Selection should therefore be based on the required signal type and host relay configuration rather than physical appearance alone.


Key Advantages

  • GE Multilin UR Series digital I/O hardware
  • Model UR 6DH
  • Provides discrete signal interfacing
  • Connects external equipment with relay logic
  • Supports equipment status monitoring
  • Suitable for breaker and switchgear applications
  • Supports alarm and interlock functions
  • Integrates with configured protection and control logic
  • Suitable for utility and industrial power systems
  • Useful for maintenance and replacement applications

Technical FAQs

How does the UR 6DH fit into a GE Multilin UR protection system?

The UR 6DH forms part of the relay’s digital I/O architecture, connecting discrete external equipment conditions with the processor and configured protection or automation logic.

What types of signals are typically associated with a digital I/O module?

Typical applications involve binary equipment conditions such as breaker position, auxiliary contact status, switch states, alarms, and interlock conditions. The exact signal assignment depends on the host relay configuration.

Why should the existing I/O configuration be documented before module replacement?

Digital I/O circuits are directly connected to external equipment and relay logic. Recording the existing signal assignments and wiring helps ensure that the replacement module is installed consistently with the original protection and control scheme.

How can an engineer distinguish an I/O module problem from an external circuit problem?

The complete signal path should be checked systematically, including control voltage, field contacts, wiring, terminals, connectors, module configuration, and relay diagnostics. Comparing the expected signal with the actual relay indication can help isolate the location of the fault.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501