Product Overview The Siemens 6AG1135-6HD00-7BA1 SIPLUS ET 200SP Analog Output Module is an analog output module for the SIPLUS ET 200SP distributed I/O platform. It belongs to the output side of the ET ……
Siemens 6AG1135-6HD00-7BA1 SIPLUS ET 200SP Analog Output Module
  • Siemens
  • 6AG1135-6HD00-7BA1
  • Analog Output Module
  • Germany
  • 15 × 73 × 58 mm
  • 0.039 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 20

Our advantage

Siemens 6AG1135-6HD00-7BA1 SIPLUS ET 200SP Analog Output Module

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Siemens 6AG1135-6HD00-7BA1 SIPLUS ET 200SP Analog Output Module

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Siemens 6AG1135-6HD00-7BA1 SIPLUS ET 200SP Analog Output Module

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Siemens 6AG1135-6HD00-7BA1 SIPLUS ET 200SP Analog Output Module

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Siemens 6AG1135-6HD00-7BA1 SIPLUS ET 200SP Analog Output Module is an analog output module for the SIPLUS ET 200SP distributed I/O platform. It belongs to the output side of the ET 200SP architecture and converts controller-generated analog values into electrical output signals for connected field devices.

In an automation system, the module is typically positioned between the PLC or distributed controller and analog actuators or other analog-controlled equipment. This makes it suitable for applications where a control program needs to regulate variables such as speed, position, pressure, temperature, flow, or valve opening through an analog signal.

As a SIPLUS component, the module is intended for automation installations that require enhanced environmental suitability compared with standard industrial hardware. It can be integrated into distributed I/O stations where compact installation and modular expansion are important.


Technical Specifications

Parameter Specification
Manufacturer Siemens
Model 6AG1135-6HD00-7BA1
Product Family SIPLUS ET 200SP
Product Type Analog Output Module
Application Distributed I/O / Industrial Automation
Dimensions 15 × 73 × 58 mm
Weight 0.039 kg

Product Features

The 6AG1135-6HD00-7BA1 combines analog output functionality with the modular architecture of the ET 200SP platform.

Key characteristics include:

  • Siemens SIPLUS ET 200SP analog output module
  • Model 6AG1135-6HD00-7BA1
  • Designed for distributed analog output applications
  • Compact ET 200SP module format
  • Integrates with the ET 200SP station architecture
  • Converts controller output values into analog field signals
  • Suitable for process and machine control applications
  • Supports modular I/O expansion
  • Suitable for automation environments requiring SIPLUS hardware
  • Intended for integration with compatible ET 200SP system components

The complete station configuration should be considered when selecting the module, including the associated interface module, BaseUnit, wiring arrangement, and controller-side configuration.


Working Principle

The module receives an output value from the PLC through the ET 200SP backplane and converts the digital control value into the corresponding analog output signal.

A simplified control path is:

PLC / Controller → ET 200SP Interface → Analog Output Module → Analog Signal → Field Device

The controller determines the required process value through the user program. The analog output module then processes this digital value and produces the corresponding electrical output for the connected actuator or control device.

For example, an analog output can be used to command a variable-speed drive, position a control valve, or regulate another device that accepts an analog reference.

Because the module operates within a distributed I/O station, communication with the higher-level controller and signal generation at the field level are handled as separate but coordinated parts of the control architecture.


Role in a Distributed I/O Architecture

The 6AG1135-6HD00-7BA1 occupies the analog output layer of an ET 200SP distributed I/O station.

A typical architecture can be represented as:

PLC / CPU → PROFINET Network → ET 200SP Interface Module → Analog Output Module → Field Actuator

The controller handles application logic and determines the desired output value. The ET 200SP station transfers this command to the analog output module, which generates the corresponding field-side analog signal.

Typical connected devices may include:

  • Variable-speed drive references
  • Proportional valves
  • Actuator position commands
  • Process controllers
  • Analog control inputs
  • Other equipment requiring continuously variable electrical signals

This arrangement allows analog control points to be installed close to the machine or process equipment while keeping the main PLC architecture centralized.


Industrial Applications

The module is suitable for distributed automation systems where analog control signals need to be generated at the field level.

Application Typical Use
Process Automation Analog regulation of process variables
Machine Automation Analog actuator control
Motor Control Speed-reference signal generation
Valve Control Proportional valve positioning
HVAC Systems Continuous control of equipment
Packaging Machinery Analog control of machine functions
Material Handling Variable-speed equipment control
Production Lines Distributed analog output control
Industrial Process Equipment Field-level analog command generation

Its practical application depends on the signal requirements of the connected field device and the configuration of the ET 200SP station.


Installation and Maintenance

Installation should begin by confirming the ET 200SP station architecture and the exact module configuration.

Recommended practices include:

  • Confirm the complete 6AG1135-6HD00-7BA1 order number.
  • Verify compatibility with the intended ET 200SP station.
  • Confirm the required interface module and BaseUnit arrangement.
  • Switch the relevant system section to a safe maintenance state.
  • Inspect the module and connector interfaces before installation.
  • Install the module in the correct ET 200SP position.
  • Confirm proper mechanical seating.
  • Connect field wiring according to the configured output channel arrangement.
  • Check wiring polarity and signal routing.
  • Configure the module correctly in the PLC engineering environment.
  • Verify the assigned I/O addresses or process data mapping.
  • Test the analog output under controlled conditions.
  • Confirm the connected actuator responds correctly.
  • Monitor the output during normal machine operation.

When troubleshooting an analog output problem, the investigation should include the controller configuration, network communication, module status, BaseUnit, wiring, and field device rather than assuming that the output module itself is defective.


Related Components

The analog output module operates as part of a complete ET 200SP station.

Component Function
Siemens ET 200SP Interface Module Connects the distributed I/O station to the control network
ET 200SP BaseUnit Provides the module mounting and electrical connection structure
ET 200SP CPU / PLC Executes the automation program
PROFINET Network Transfers process data between controller and I/O station
Analog Output Module Generates analog control signals
Field Actuator Receives the analog command
Engineering Software Provides hardware configuration and diagnostics
24 V DC Power Supply Supplies system and field-side power as required
Terminal Wiring Connects the I/O station with field devices

Correct interaction between these components is necessary for reliable analog output operation.


Recommended Related Models

Model / Product Family Product Type Typical Application
Siemens 6AG1135-6HD00-7BA1 SIPLUS ET 200SP Analog Output Module Distributed analog output
Siemens SIPLUS ET 200SP Analog I/O Modules Analog I/O Process signal interfacing
Siemens ET 200SP Interface Modules Interface Module Distributed I/O network connection
Siemens ET 200SP BaseUnits BaseUnit Module mounting and wiring
Siemens SIMATIC S7-1500 PLC / CPU Platform Central control
Siemens SIMATIC S7-1200 PLC / CPU Platform Compact machine control

The 6AG1135-6HD00-7BA1 should be selected according to the required analog output function and the complete ET 200SP station configuration.


Key Advantages

  • Siemens SIPLUS ET 200SP analog output module
  • Model 6AG1135-6HD00-7BA1
  • Suitable for distributed analog signal generation
  • Integrates into the modular ET 200SP architecture
  • Supports field-level actuator control
  • Compact installation within distributed I/O stations
  • Suitable for machine and process automation
  • Supports centralized PLC logic with distributed field outputs
  • Appropriate for industrial applications requiring SIPLUS equipment

Technical FAQs

What is the role of the 6AG1135-6HD00-7BA1 in an ET 200SP station?

The module handles analog output functions within the ET 200SP distributed I/O station. It receives process data from the controller and converts the commanded value into an analog electrical output for compatible field equipment.

How does an analog output module differ from an ET 200SP digital output module?

A digital output normally represents discrete states such as ON and OFF, while an analog output represents a continuously variable control value. This makes an analog output more appropriate for applications such as proportional valve control or variable-speed references.

Which components should be checked when an ET 200SP analog output does not produce the expected signal?

Troubleshooting should cover the PLC program and configuration, network communication, ET 200SP interface module, BaseUnit, output module status, field wiring, and the receiving actuator. Measuring the actual output signal can help determine whether the fault is on the controller, I/O, wiring, or field-device side.

Where is the 6AG1135-6HD00-7BA1 typically used in a control system?

It is used at the distributed field-I/O level between the ET 200SP station and analog-controlled equipment. Typical applications include variable-speed control, proportional valve positioning, process regulation, and other automation functions requiring analog commands.



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501