Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Schneider 170ENT11002 is an Ethernet TCP/IP Communication Adapter designed for industrial automation systems that require network communication between distributed I/O equipment and a central control system. As part of the Schneider Modicon 170 automation architecture, this adapter provides a communication interface for connecting compatible remote I/O equipment to an Ethernet-based industrial control network.
Distributed I/O is commonly used when field devices are located away from the main PLC cabinet. Instead of bringing every sensor and actuator signal back to a centralized control panel through individual cables, remote I/O stations can be installed closer to the process. The communication adapter then provides the network connection between the remote I/O station and the controller.
The 170ENT11002 therefore serves primarily as a communication interface. It is not intended to replace the PLC processor or independently execute the complete application-control program. Its function is to support the exchange of input, output, status, and diagnostic information between the remote I/O architecture and the Ethernet TCP/IP network.
This type of communication architecture can be useful in manufacturing equipment, process automation, machine control, material handling, and other industrial systems where distributed field signals need to be connected to a central controller.
The specified dimensions of the Schneider 170ENT11002 are 56 × 178 × 259 mm, and the specified weight is 0.07 kg.
| Parameter | Details |
|---|---|
| Manufacturer | Schneider Electric |
| Model | 170ENT11002 |
| Product Type | Ethernet TCP/IP Communication Adapter |
| Product Family | Modicon 170 Series |
| Primary Function | Ethernet communication for distributed I/O |
| Communication Technology | Ethernet TCP/IP |
| System Role | Remote I/O communication interface |
| Application | Industrial automation and distributed control |
| Controller Integration | PLC-based control systems |
| Network Type | Industrial Ethernet |
| Installation | Industrial control / remote I/O system |
| Dimensions | 56 × 178 × 259 mm |
| Weight | 0.07 kg |
| Communication Role | Data exchange between remote I/O and controller |
| Typical Application | Distributed PLC and remote I/O systems |
| Maintenance Use | System replacement, maintenance and troubleshooting |
The Schneider 170ENT11002 is an Ethernet TCP/IP communication adapter intended for use within Schneider Modicon 170 series automation systems.
Its primary purpose is to provide a network communication path between compatible remote I/O equipment and an Ethernet-based control system. The adapter allows I/O information collected at a remote location to be transferred to the PLC or other control equipment through the industrial Ethernet network.
In a typical distributed automation installation, the adapter works together with remote I/O modules rather than operating as a standalone controller. The remote I/O modules collect signals from field devices, while the communication adapter provides the connection between the I/O system and the network.
This architecture allows the controller to monitor and control equipment that may be physically separated from the main control cabinet.
The operating principle of the 170ENT11002 can be understood by following the flow of process data through the automation system.
A simplified input path is:
Field Sensor → Remote I/O Module → 170ENT11002 → Ethernet TCP/IP Network → PLC Controller
When a sensor, switch, transmitter, or other field device produces a signal, the appropriate remote I/O module receives the signal. The I/O information is then made available to the communication system.
The 170ENT11002 provides the network communication path through which the information is exchanged with the central controller.
For output control, the communication direction is reversed:
PLC Controller → Ethernet Network → 170ENT11002 → Remote I/O Module → Actuator
This allows the PLC to control motors, valves, solenoids, contactors, indicators, and other field devices located at the remote I/O station.
The communication adapter therefore acts as an important interface between the network layer and the distributed I/O layer.
The 170ENT11002 can contribute to a distributed control architecture by separating field signal wiring from the central PLC cabinet.
In a centralized system, every input and output may require an individual cable between the field device and the main controller. When the field devices are distributed across a large machine or facility, this can create a large and complicated wiring system.
A remote I/O architecture can instead place I/O modules near the process.
The architecture can be organized as follows:
This approach can reduce long-distance field wiring and provide a more organized control-system structure.
Ethernet TCP/IP provides a widely used network foundation for industrial automation systems. It allows automation devices to exchange information using structured network communication.
Within a distributed PLC system, Ethernet may connect:
The 170ENT11002 is positioned at the remote I/O communication layer and provides the connection between compatible I/O equipment and the Ethernet control network.
Stable communication depends not only on the adapter but also on the quality of the surrounding network. Ethernet cable condition, connectors, addressing, switch operation, grounding, and cable routing should all be considered during system commissioning.
The Schneider 170ENT11002 can be used in distributed industrial automation applications where remote I/O needs to communicate with a central control system.
Typical application areas include:
Its communication function is especially useful when the physical distance between field devices and the main PLC makes centralized wiring impractical.
The 170ENT11002 normally forms part of a larger automation system and works together with several types of control equipment.
| Component | Type | Typical Function |
|---|---|---|
| 170ENT11002 | Ethernet TCP/IP Communication Adapter | Provides Ethernet communication for remote I/O |
| Modicon 170 I/O Modules | Remote I/O | Collects inputs and controls outputs |
| PLC Controller | Control Processor | Executes the application program |
| Ethernet Switch | Network Device | Connects Ethernet nodes |
| Industrial Ethernet Cable | Network Cable | Provides network communication |
| Digital Input Modules | I/O Module | Collects discrete signals |
| Digital Output Modules | I/O Module | Controls discrete devices |
| Analog Input Modules | I/O Module | Measures analog process signals |
| Analog Output Modules | I/O Module | Provides analog control signals |
| HMI | Operator Interface | Monitoring and operator control |
| Engineering Workstation | Industrial Computer | Configuration and diagnostics |
The exact system configuration depends on the required number and type of I/O points and the overall PLC architecture.
Correct installation is important for ensuring stable communication between the 170ENT11002 and the industrial Ethernet network.
A general installation procedure includes:
The actual procedure should be adapted to the specific Schneider automation system and the maintenance requirements of the installation.
When the 170ENT11002 is integrated into an existing Ethernet network, the complete communication path should be considered.
A simplified network structure is:
Remote I/O → 170ENT11002 → Ethernet Switch → Control Network → PLC
If the remote I/O station cannot communicate with the PLC, technicians should inspect the communication path from the adapter outward.
Important checks include:
Network problems should not automatically be attributed to the communication adapter.
Troubleshooting the Schneider 170ENT11002 should be performed systematically. The first objective is to determine whether the problem affects the complete remote I/O station or only a particular I/O module or communication channel.
| Observed Condition | Possible Area to Check |
|---|---|
| No Ethernet communication | Power, adapter, cable, switch or network configuration |
| Remote I/O unavailable | Communication adapter, network or I/O configuration |
| Intermittent communication | Cable, connector, electrical noise or network equipment |
| Input data missing | Input module, adapter, network or PLC configuration |
| Output command missing | PLC, adapter, network or output module |
| Communication alarm | Addressing, configuration or physical connection |
| Adapter not detected | Power, installation or system configuration |
| Complete I/O station failure | Common communication path, adapter or power |
A practical troubleshooting sequence is:
Power → Adapter Status → Ethernet Cable → Network Switch → Network Configuration → PLC → Remote I/O → Field Devices
This sequence can help technicians determine whether the fault is related to the adapter or another part of the automation system.
Communication faults may result from hardware, wiring, configuration, or environmental conditions.
Checking these conditions before replacing the adapter can help prevent unnecessary component replacement.
When sourcing a replacement for the Schneider 170ENT11002, the complete model number should be verified carefully.
Important information includes:
Physical dimensions alone are not sufficient to establish compatibility. Similar-looking communication modules may use different hardware architectures or communication functions.
The following models and product categories may be considered for comparison or replacement planning. They should not automatically be considered direct substitutes for the 170ENT11002 without verifying the complete system configuration.
| Model | Type | Key Feature | Application |
|---|---|---|---|
| 170ENT11002 | Ethernet TCP/IP Communication Adapter | Distributed I/O Ethernet communication | Modicon 170 systems |
| 170ENT11001 | Ethernet TCP/IP Communication Adapter | Remote I/O network interface | Industrial automation |
| 170ENT11000 | Ethernet Communication Adapter | Industrial Ethernet connectivity | Distributed I/O |
| 170NEF11021 | Ethernet Communication Module | Ethernet-based system communication | Modicon automation |
| Modicon Ethernet I/O Adapters | Communication Interface | Remote I/O connectivity | PLC systems |
| Modicon Remote I/O Modules | Remote I/O | Distributed signal acquisition | Factory automation |
| Modicon Ethernet Communication Modules | Network Module | PLC network integration | Industrial control |
| Industrial Ethernet Gateways | Communication Gateway | Protocol and network integration | Distributed automation |
Replacement recommendation: For an existing system, the exact Schneider 170ENT11002 should be preferred whenever possible. A different communication adapter should only be selected after confirming the PLC architecture, remote I/O configuration, communication requirements, and network compatibility.
The Schneider 170ENT11002 is an Ethernet TCP/IP Communication Adapter designed for distributed I/O and industrial automation applications within the Modicon 170 architecture.
Its primary function is to provide Ethernet communication between compatible remote I/O equipment and the industrial control network.
No. It is a communication adapter rather than an independent PLC processor. The PLC performs the application-control logic while the adapter provides the network communication path.
The product is identified as an Ethernet TCP/IP Communication Adapter and is designed for Ethernet-based industrial communication.
The specified dimensions are 56 × 178 × 259 mm.
The specified weight is 0.07 kg.
Typical associated equipment includes compatible Modicon 170 remote I/O modules, PLC controllers, Ethernet switches, industrial Ethernet cables, digital and analog I/O modules, HMIs, and engineering workstations.
Possible causes include damaged Ethernet cables, loose connectors, network switch problems, incorrect network addressing, configuration errors, electrical interference, power problems, or communication adapter hardware failure.
Begin by checking power and physical connections. Then check the Ethernet cable, network switch, network configuration, PLC communication, remote I/O status, and field devices.
It should not be assumed that the two models are directly interchangeable. Although both are identified as Ethernet TCP/IP communication adapters, compatibility must be confirmed against the specific Modicon 170 system configuration.
Remote I/O communication allows field signals to be collected closer to the process while the central PLC remains in a main control cabinet. This can reduce wiring complexity and simplify distributed system design.
The model number, remote I/O configuration, PLC controller, network architecture, Ethernet connections, network addressing, and communication configuration should be verified before replacement.
The Schneider 170ENT11002 Ethernet TCP/IP Communication Adapter is a specialized communication component for distributed industrial automation systems. Its primary role is to provide a network communication path between compatible remote I/O equipment and a central PLC or control network.
By supporting Ethernet-based communication, the adapter allows remote I/O stations to be positioned closer to field equipment while maintaining communication with the central controller. This architecture can help reduce field wiring, improve system organization, and support distributed automation applications.
The specified dimensions are 56 × 178 × 259 mm, and the specified weight is 0.07 kg. These physical specifications are useful when evaluating cabinet space, replacement requirements, and spare-parts logistics.
For maintenance engineers, system integrators, and automation professionals, accurate identification of the 170ENT11002 is essential before replacement. The complete remote I/O configuration, PLC architecture, Ethernet network, cable connections, and communication parameters should be checked to ensure compatibility.
When integrated into a suitable Modicon automation architecture, the Schneider 170ENT11002 provides an important Ethernet communication interface for distributed I/O, helping industrial control systems exchange process data between remote field equipment and centralized PLC control.