Product Overview The Schneider 170ENT11002 is an Ethernet TCP/IP Communication Adapter designed for industrial automation systems that require network communication between distributed I/O equipment an……
Schneider 170ENT11002 Ethernet TCP/IP Communication Adapter
  • Schneider
  • 170ENT11002
  • Ethernet TCP/IP Communication Adapter
  • France
  • 56 x 178 x 259 mm
  • 0.07 kg
  • Xiamen, China
  • New & In Stock
  • T/T, PayPal, Western Union
  • 1 Year
  • 1-3 Working Days
  • DHL, UPS, TNT, FedEx and EMS.
  • 24-Hour Service
  • COO
  • 7

Our advantage

Schneider 170ENT11002 Ethernet TCP/IP Communication Adapter

Global Logistics

We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.

Schneider 170ENT11002 Ethernet TCP/IP Communication Adapter

Brand new and original

Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.

Schneider 170ENT11002 Ethernet TCP/IP Communication Adapter

24-hour service

We provide 7*24 hours service to our customers. We will be there whenever you need us.

Schneider 170ENT11002 Ethernet TCP/IP Communication Adapter

Price advantage

All our products are priced very favorably because we have our own warehouse and supply.


Company Information
E-mail [email protected]
Mobile +8615980777398
Whatsapp +8615980777398
WeChat 15980777398

Product Overview

The Schneider 170ENT11002 is an Ethernet TCP/IP Communication Adapter designed for industrial automation systems that require network communication between distributed I/O equipment and a central control system. As part of the Schneider Modicon 170 automation architecture, this adapter provides a communication interface for connecting compatible remote I/O equipment to an Ethernet-based industrial control network.

Distributed I/O is commonly used when field devices are located away from the main PLC cabinet. Instead of bringing every sensor and actuator signal back to a centralized control panel through individual cables, remote I/O stations can be installed closer to the process. The communication adapter then provides the network connection between the remote I/O station and the controller.

The 170ENT11002 therefore serves primarily as a communication interface. It is not intended to replace the PLC processor or independently execute the complete application-control program. Its function is to support the exchange of input, output, status, and diagnostic information between the remote I/O architecture and the Ethernet TCP/IP network.

This type of communication architecture can be useful in manufacturing equipment, process automation, machine control, material handling, and other industrial systems where distributed field signals need to be connected to a central controller.

The specified dimensions of the Schneider 170ENT11002 are 56 × 178 × 259 mm, and the specified weight is 0.07 kg.

Technical Specifications

Parameter Details
Manufacturer Schneider Electric
Model 170ENT11002
Product Type Ethernet TCP/IP Communication Adapter
Product Family Modicon 170 Series
Primary Function Ethernet communication for distributed I/O
Communication Technology Ethernet TCP/IP
System Role Remote I/O communication interface
Application Industrial automation and distributed control
Controller Integration PLC-based control systems
Network Type Industrial Ethernet
Installation Industrial control / remote I/O system
Dimensions 56 × 178 × 259 mm
Weight 0.07 kg
Communication Role Data exchange between remote I/O and controller
Typical Application Distributed PLC and remote I/O systems
Maintenance Use System replacement, maintenance and troubleshooting

What Is the Schneider 170ENT11002?

The Schneider 170ENT11002 is an Ethernet TCP/IP communication adapter intended for use within Schneider Modicon 170 series automation systems.

Its primary purpose is to provide a network communication path between compatible remote I/O equipment and an Ethernet-based control system. The adapter allows I/O information collected at a remote location to be transferred to the PLC or other control equipment through the industrial Ethernet network.

In a typical distributed automation installation, the adapter works together with remote I/O modules rather than operating as a standalone controller. The remote I/O modules collect signals from field devices, while the communication adapter provides the connection between the I/O system and the network.

This architecture allows the controller to monitor and control equipment that may be physically separated from the main control cabinet.

Function and Working Principle

The operating principle of the 170ENT11002 can be understood by following the flow of process data through the automation system.

A simplified input path is:

Field Sensor → Remote I/O Module → 170ENT11002 → Ethernet TCP/IP Network → PLC Controller

When a sensor, switch, transmitter, or other field device produces a signal, the appropriate remote I/O module receives the signal. The I/O information is then made available to the communication system.

The 170ENT11002 provides the network communication path through which the information is exchanged with the central controller.

For output control, the communication direction is reversed:

PLC Controller → Ethernet Network → 170ENT11002 → Remote I/O Module → Actuator

This allows the PLC to control motors, valves, solenoids, contactors, indicators, and other field devices located at the remote I/O station.

The communication adapter therefore acts as an important interface between the network layer and the distributed I/O layer.

Role in Industrial Control Systems

The 170ENT11002 can contribute to a distributed control architecture by separating field signal wiring from the central PLC cabinet.

In a centralized system, every input and output may require an individual cable between the field device and the main controller. When the field devices are distributed across a large machine or facility, this can create a large and complicated wiring system.

A remote I/O architecture can instead place I/O modules near the process.

The architecture can be organized as follows:

  • Field devices are connected to local I/O modules.
  • The remote I/O station is connected to the communication adapter.
  • The communication adapter is connected to the Ethernet network.
  • The Ethernet network connects the remote station to the PLC.
  • The PLC executes the application-control logic.
  • Control commands are transmitted back to the remote I/O station.

This approach can reduce long-distance field wiring and provide a more organized control-system structure.

Ethernet TCP/IP Communication

Ethernet TCP/IP provides a widely used network foundation for industrial automation systems. It allows automation devices to exchange information using structured network communication.

Within a distributed PLC system, Ethernet may connect:

  • PLC controllers
  • Remote I/O adapters
  • Industrial Ethernet switches
  • Operator terminals
  • Engineering workstations
  • Supervisory systems
  • Communication gateways
  • Other industrial network devices

The 170ENT11002 is positioned at the remote I/O communication layer and provides the connection between compatible I/O equipment and the Ethernet control network.

Stable communication depends not only on the adapter but also on the quality of the surrounding network. Ethernet cable condition, connectors, addressing, switch operation, grounding, and cable routing should all be considered during system commissioning.

Industrial Applications

The Schneider 170ENT11002 can be used in distributed industrial automation applications where remote I/O needs to communicate with a central control system.

Typical application areas include:

  • Factory automation
  • Production lines
  • Machine control
  • Packaging systems
  • Material handling
  • Process automation
  • Water and wastewater systems
  • Industrial equipment monitoring
  • Distributed machine automation
  • Manufacturing systems
  • Remote I/O installations

Its communication function is especially useful when the physical distance between field devices and the main PLC makes centralized wiring impractical.

Compatible System Components

The 170ENT11002 normally forms part of a larger automation system and works together with several types of control equipment.

Component Type Typical Function
170ENT11002 Ethernet TCP/IP Communication Adapter Provides Ethernet communication for remote I/O
Modicon 170 I/O Modules Remote I/O Collects inputs and controls outputs
PLC Controller Control Processor Executes the application program
Ethernet Switch Network Device Connects Ethernet nodes
Industrial Ethernet Cable Network Cable Provides network communication
Digital Input Modules I/O Module Collects discrete signals
Digital Output Modules I/O Module Controls discrete devices
Analog Input Modules I/O Module Measures analog process signals
Analog Output Modules I/O Module Provides analog control signals
HMI Operator Interface Monitoring and operator control
Engineering Workstation Industrial Computer Configuration and diagnostics

The exact system configuration depends on the required number and type of I/O points and the overall PLC architecture.

Installation and System Integration

Correct installation is important for ensuring stable communication between the 170ENT11002 and the industrial Ethernet network.

A general installation procedure includes:

  1. Place the automation system in the approved maintenance condition.
  2. Follow the site’s electrical isolation and safety procedures.
  3. Identify the existing communication adapter.
  4. Verify the complete 170ENT11002 model number.
  5. Record existing Ethernet connections.
  6. Document the associated remote I/O modules.
  7. Inspect the replacement adapter for physical damage.
  8. Verify the mounting location.
  9. Install the adapter correctly.
  10. Connect the Ethernet cable.
  11. Check the remote I/O connections.
  12. Verify cable routing and mechanical protection.
  13. Check grounding and shielding.
  14. Restore system power.
  15. Check communication status.
  16. Verify network connectivity.
  17. Confirm communication with the PLC.
  18. Verify input data.
  19. Verify output commands.
  20. Complete a functional test.

The actual procedure should be adapted to the specific Schneider automation system and the maintenance requirements of the installation.

Network Integration Considerations

When the 170ENT11002 is integrated into an existing Ethernet network, the complete communication path should be considered.

A simplified network structure is:

Remote I/O → 170ENT11002 → Ethernet Switch → Control Network → PLC

If the remote I/O station cannot communicate with the PLC, technicians should inspect the communication path from the adapter outward.

Important checks include:

  • Power supply
  • Ethernet cable connection
  • Connector condition
  • Network switch status
  • Network addressing
  • PLC communication configuration
  • Remote I/O configuration
  • Physical cable condition
  • Electrical interference

Network problems should not automatically be attributed to the communication adapter.

Maintenance and Troubleshooting

Troubleshooting the Schneider 170ENT11002 should be performed systematically. The first objective is to determine whether the problem affects the complete remote I/O station or only a particular I/O module or communication channel.

Observed Condition Possible Area to Check
No Ethernet communication Power, adapter, cable, switch or network configuration
Remote I/O unavailable Communication adapter, network or I/O configuration
Intermittent communication Cable, connector, electrical noise or network equipment
Input data missing Input module, adapter, network or PLC configuration
Output command missing PLC, adapter, network or output module
Communication alarm Addressing, configuration or physical connection
Adapter not detected Power, installation or system configuration
Complete I/O station failure Common communication path, adapter or power

A practical troubleshooting sequence is:

Power → Adapter Status → Ethernet Cable → Network Switch → Network Configuration → PLC → Remote I/O → Field Devices

This sequence can help technicians determine whether the fault is related to the adapter or another part of the automation system.

Common Causes of Communication Problems

Communication faults may result from hardware, wiring, configuration, or environmental conditions.

  • Loose Ethernet cable
  • Damaged network cable
  • Faulty connector
  • Network switch malfunction
  • Incorrect network addressing
  • Incorrect communication configuration
  • Electrical interference
  • Poor cable routing
  • Grounding problems
  • Power supply instability
  • Remote I/O configuration errors
  • Communication adapter failure
  • PLC configuration problems

Checking these conditions before replacing the adapter can help prevent unnecessary component replacement.

Replacement Considerations

When sourcing a replacement for the Schneider 170ENT11002, the complete model number should be verified carefully.

Important information includes:

  • 170ENT11002 model number
  • Modicon 170 I/O configuration
  • PLC controller type
  • Ethernet network structure
  • Network addressing
  • Ethernet cable connections
  • Installation location
  • Required communication function

Physical dimensions alone are not sufficient to establish compatibility. Similar-looking communication modules may use different hardware architectures or communication functions.

Recommended Alternative Models

The following models and product categories may be considered for comparison or replacement planning. They should not automatically be considered direct substitutes for the 170ENT11002 without verifying the complete system configuration.

Model Type Key Feature Application
170ENT11002 Ethernet TCP/IP Communication Adapter Distributed I/O Ethernet communication Modicon 170 systems
170ENT11001 Ethernet TCP/IP Communication Adapter Remote I/O network interface Industrial automation
170ENT11000 Ethernet Communication Adapter Industrial Ethernet connectivity Distributed I/O
170NEF11021 Ethernet Communication Module Ethernet-based system communication Modicon automation
Modicon Ethernet I/O Adapters Communication Interface Remote I/O connectivity PLC systems
Modicon Remote I/O Modules Remote I/O Distributed signal acquisition Factory automation
Modicon Ethernet Communication Modules Network Module PLC network integration Industrial control
Industrial Ethernet Gateways Communication Gateway Protocol and network integration Distributed automation

Replacement recommendation: For an existing system, the exact Schneider 170ENT11002 should be preferred whenever possible. A different communication adapter should only be selected after confirming the PLC architecture, remote I/O configuration, communication requirements, and network compatibility.

Key Advantages

  • Provides Ethernet TCP/IP communication for distributed I/O
  • Supports remote I/O integration with PLC systems
  • Helps reduce long-distance field wiring
  • Supports distributed industrial automation architectures
  • Provides a dedicated network communication interface
  • Supports centralized PLC monitoring and control
  • Can simplify remote I/O system organization
  • Suitable for industrial Ethernet-based automation
  • Useful for maintaining established Modicon 170 systems
  • Compact communication adapter design

Technical FAQs

What is the Schneider 170ENT11002?

The Schneider 170ENT11002 is an Ethernet TCP/IP Communication Adapter designed for distributed I/O and industrial automation applications within the Modicon 170 architecture.

What is the main function of the 170ENT11002?

Its primary function is to provide Ethernet communication between compatible remote I/O equipment and the industrial control network.

Is the 170ENT11002 a PLC CPU?

No. It is a communication adapter rather than an independent PLC processor. The PLC performs the application-control logic while the adapter provides the network communication path.

What communication technology does it use?

The product is identified as an Ethernet TCP/IP Communication Adapter and is designed for Ethernet-based industrial communication.

What are the dimensions of the 170ENT11002?

The specified dimensions are 56 × 178 × 259 mm.

What is the weight of the 170ENT11002?

The specified weight is 0.07 kg.

What equipment works with the 170ENT11002?

Typical associated equipment includes compatible Modicon 170 remote I/O modules, PLC controllers, Ethernet switches, industrial Ethernet cables, digital and analog I/O modules, HMIs, and engineering workstations.

What can cause communication failure?

Possible causes include damaged Ethernet cables, loose connectors, network switch problems, incorrect network addressing, configuration errors, electrical interference, power problems, or communication adapter hardware failure.

How should the 170ENT11002 be troubleshot?

Begin by checking power and physical connections. Then check the Ethernet cable, network switch, network configuration, PLC communication, remote I/O status, and field devices.

Can the 170ENT11001 replace the 170ENT11002?

It should not be assumed that the two models are directly interchangeable. Although both are identified as Ethernet TCP/IP communication adapters, compatibility must be confirmed against the specific Modicon 170 system configuration.

Why is remote I/O communication useful?

Remote I/O communication allows field signals to be collected closer to the process while the central PLC remains in a main control cabinet. This can reduce wiring complexity and simplify distributed system design.

What should be checked before replacing the adapter?

The model number, remote I/O configuration, PLC controller, network architecture, Ethernet connections, network addressing, and communication configuration should be verified before replacement.

Conclusion

The Schneider 170ENT11002 Ethernet TCP/IP Communication Adapter is a specialized communication component for distributed industrial automation systems. Its primary role is to provide a network communication path between compatible remote I/O equipment and a central PLC or control network.

By supporting Ethernet-based communication, the adapter allows remote I/O stations to be positioned closer to field equipment while maintaining communication with the central controller. This architecture can help reduce field wiring, improve system organization, and support distributed automation applications.

The specified dimensions are 56 × 178 × 259 mm, and the specified weight is 0.07 kg. These physical specifications are useful when evaluating cabinet space, replacement requirements, and spare-parts logistics.

For maintenance engineers, system integrators, and automation professionals, accurate identification of the 170ENT11002 is essential before replacement. The complete remote I/O configuration, PLC architecture, Ethernet network, cable connections, and communication parameters should be checked to ensure compatibility.

When integrated into a suitable Modicon automation architecture, the Schneider 170ENT11002 provides an important Ethernet communication interface for distributed I/O, helping industrial control systems exchange process data between remote field equipment and centralized PLC control.

 



Related Products

Get the latest price? We will reply as soon as possible (within 12 hours)

No:77501