Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
| Company Information | |||
| [email protected] | |||
| Mobile | +8615980777398 | ||
| +8615980777398 | |||
| 15980777398 |

The Allen Bradley 1734-ADN/B POINT I/O DeviceNet Network Adaptor is a communication interface used to connect a POINT I/O station to a DeviceNet network.
In a distributed automation system, I/O modules are often installed close to sensors, actuators, and machine equipment rather than inside the main controller cabinet. The network adaptor provides the communication path between those local POINT I/O modules and the DeviceNet control network.
A typical installation might place a group of digital and analog I/O modules near a conveyor, packaging machine, or process skid. Field signals are connected to the POINT I/O modules, while the 1734-ADN/B handles communication between the local I/O assembly and the DeviceNet network.
This arrangement reduces the amount of individual field wiring that needs to return to the main control cabinet and makes it easier to distribute I/O around a machine or production area.
| Parameter | Details |
|---|---|
| Manufacturer | Allen Bradley |
| Model | 1734-ADN/B |
| Product Type | POINT I/O DeviceNet Network Adaptor |
| Series | POINT I/O |
| Network | DeviceNet |
| Main Function | Network Communication for POINT I/O |
| System Role | I/O Network Adaptor |
| Application | Distributed I/O Systems |
| Typical Use | Connecting POINT I/O to DeviceNet |
| Dimensions | 133.4 × 54.9 × 76.2 mm |
| Weight | 0.26 kg |
The 1734-ADN/B forms the communication link between a POINT I/O station and the DeviceNet network.
Key characteristics include:
The adaptor should be considered together with the POINT I/O modules, DeviceNet network, power arrangement, and controller when planning or troubleshooting the station.
A typical POINT I/O DeviceNet arrangement can be represented as:
PLC / DeviceNet Scanner → DeviceNet Network → 1734-ADN/B → POINT I/O Modules → Field Devices
The controller communicates with the remote I/O station through DeviceNet. The 1734-ADN/B receives the network information and manages the communication between the network and the compatible POINT I/O modules installed at the station.
For example, a machine may have several proximity sensors and solenoid valves located away from the main control cabinet. Instead of running separate signal wiring for every device back to the PLC, the field devices can connect to local POINT I/O modules. The 1734-ADN/B then provides the network connection between this local I/O group and the controller.
During troubleshooting, this makes the adaptor a useful dividing point. If the controller cannot communicate with an entire POINT I/O station, the DeviceNet connection, adaptor, station power, and module assembly should be checked before investigating individual I/O channels.
The 1734-ADN/B is suited to applications where POINT I/O modules need to be distributed over a DeviceNet network.
| Application | Typical Use |
|---|---|
| Packaging Machinery | Distributed sensor and actuator I/O |
| Conveyor Systems | Remote machine signals |
| Material Handling | Distributed digital and analog I/O |
| Assembly Equipment | Local machine I/O |
| Production Lines | Remote I/O stations |
| Machine Control | Device-level field interfaces |
| Process Equipment | Distributed monitoring and control |
| Industrial Automation | Networked POINT I/O systems |
The final configuration depends on the controller, DeviceNet network architecture, POINT I/O modules, and field devices connected to the station.
The 1734-ADN/B normally operates as part of a complete POINT I/O and DeviceNet system.
| Component | Function |
|---|---|
| 1734-ADN/B | Connects the POINT I/O station to DeviceNet |
| POINT I/O Modules | Interface with field signals |
| DeviceNet Scanner / Controller Interface | Exchanges I/O data with the network |
| PLC | Executes control logic |
| DeviceNet Network | Carries communication between controller and I/O |
| Field Sensors | Provide machine or process input signals |
| Actuators | Receive output commands |
| I/O Power Supply | Supplies the applicable station power |
| Network Cabling | Carries DeviceNet communication |
| Terminal / Wiring Components | Connect field devices |
The adaptor is only one part of the communication path. A problem in the network cable, node configuration, power supply, or I/O assembly can also interrupt communication.
The 1734-ADN/B should be installed as part of the POINT I/O station and DeviceNet network arrangement. Correct node configuration, network wiring, power distribution, and module seating are important during commissioning.
Recommended checks include:
If an entire POINT I/O station disappears from the controller, start with the common communication path. The adaptor, network wiring, power supply, and DeviceNet configuration should be examined before replacing individual I/O modules.
For the 1734-ADN/B, related components should be selected according to the required network architecture and POINT I/O station configuration.
| Model / Component | Type | Primary Function | Application |
|---|---|---|---|
| Allen Bradley 1734-ADN/B | DeviceNet Network Adaptor | POINT I/O network communication | DeviceNet I/O systems |
| Allen Bradley POINT I/O Modules | I/O Hardware | Field signal interfacing | Distributed automation |
| Allen Bradley POINT I/O Terminal Bases | Base Hardware | Module mounting and wiring interface | POINT I/O stations |
| Allen Bradley DeviceNet Scanner | Network Interface | Controller-side DeviceNet communication | PLC networks |
| Allen Bradley PLC Controllers | Controller | Machine and process control | Industrial automation |
| DeviceNet Network Components | Network Hardware | Network communication | Distributed I/O |
When replacing a 1734-ADN/B, verify the DeviceNet architecture, node configuration, compatible POINT I/O modules, station power, network wiring, and controller interface.
The 1734-ADN/B acts as a DeviceNet network adaptor for a POINT I/O station, allowing compatible POINT I/O modules to exchange I/O data with the DeviceNet control network.
Check the 1734-ADN/B, DeviceNet cabling, network connections, station power, node configuration, and controller-side DeviceNet interface. When all modules in one station are affected, the shared network path should be investigated first.
It can be diagnosed separately, but its operation depends on the complete I/O station. Module compatibility, terminal bases, power distribution, and network configuration all need to be considered when commissioning or replacing the adaptor.
The network connection carries the I/O data between the distributed station and the controller. A problem in the DeviceNet path can therefore make multiple otherwise functional I/O modules unavailable to the control system.